Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- How is a fault diagnosed by combining vibration and temperature?
The two variables are combined because they measure different consequences of the same defect: vibration reveals abnormal dynamic forces and temperature reveals energy dissipated as heat, and only together do they distinguish between similar causes.
- How is a ferrite applied to a cable?
The complete cable (all its conductors together) is passed through a ferrite core placed as close as possible to the source or exit point, choosing a material whose loss region matches the frequency of the problem. It acts on common mode, not on the useful signal.
- How is a fleet charger tested?
A fleet charger is tested by verifying energy delivery, communication with the actual vehicle models, protections, load management when several vehicles charge at once, and the effect on the site's installation and grid connection.
- How is a gas detector’s reading tested before use?
A gas detector is tested before each use with a functional test: it is briefly exposed to a reference gas to confirm that the sensors respond and the alarms activate, which is different from calibration, which adjusts the reading.
- How is a gear reducer evaluated?
A gear reducer is evaluated by combining vibration analysis, oil review, temperature and inspection, because gearing leaves its main signature at the gear mesh frequency and its sidebands, which are read in the spectrum.
- How is a generator evaluated before returning to service after a flood?
A flooded generator is evaluated without energizing it: the damage is documented, the machine is cleaned and dried in a controlled way, and insulation resistance is monitored until it can be decided whether to return it to service, rewind it or replace it.
- How is a grid-tied PV system sized?
A grid-tied PV system is sized starting from consumption and available area, estimating the energy per installed kilowatt according to the solar resource, and verifying that strings, inverter and protection devices are compatible.
- How is a ground grid designed?
Ground grid design starts from soil resistivity and fault current, and it is iterated until the calculated step and touch voltages fall below the tolerable limits.
- How Is a Guard Applied in an Insulation Measurement?
A guard is applied by connecting the surfaces or conductors that carry surface leakage to the guard terminal, so that this current is diverted and does not add to the measurement.
- How is a Hall effect sensor verified?
A Hall effect sensor is verified by powering it according to its datasheet, applying a known magnetic field or moving a magnet, and using the oscilloscope to confirm that its output changes level, or varies proportionally, at the expected points and with the expected cleanliness.
- How is a high-resistance ground improved?
A high-resistance ground is improved by increasing contact with the soil: more well-spaced parallel electrodes, greater depth or extension, or treatment of the surrounding soil, after verifying the cause.
- How Is a Limiter or Input Protector Tested?
It is verified in two regimes: with a small signal, to confirm that it has almost no effect on the useful signal, and at high power, to measure the level at which it starts limiting, how much power it lets through and how long it takes to recover.
- How is a link budget calculated?
The transmitted power and the antenna gains are added in decibels, and all the path losses, including free-space loss, are subtracted. The result is the received power, which is compared with the receiver sensitivity to obtain the margin.
- How is a live work procedure established?
A live work procedure is established only when de-energizing is impossible or unacceptable, and it includes justification, risk analysis, qualified personnel, a specific method and tools, safety distances and an emergency plan.
- How is a luminaire tested for severe weather conditions?
A luminaire is tested for severe weather by combining temperature and humidity, water and dust ingress, corrosion, radiation and vibration tests, and verifying that it maintains its optical, thermal and electrical function.
- How is a machine base verified?
A machine base is verified by checking that it is rigid and flat, that its anchors are firm and that it has no natural frequency close to running speed, through inspection, comparative vibration measurements and a soft foot check.
- How is a material conditioned before testing?
Conditioning a material before testing means bringing it to a defined, stable state of temperature and humidity, so that the measured property reflects the material and not its recent storage history.
- How Is a Material Selected for a High-Voltage Connector?
To select a material for a high-voltage connector, you evaluate its dielectric strength, its resistance to tracking and partial discharges, its thermal and mechanical stability and its compatibility with the environment, together with the geometry and the insulation distances.
- How is a measuring equipment control program organized?
A measuring equipment control program is organized around what the process needs to measure, not around the instruments available: take inventory, define the requirement for each measurement, confirm that the equipment meets it and maintain that evidence over time.
- How Is a Microwave Absorbing Material Verified?
A microwave absorbing material is verified by measuring its reflectivity, or return loss, and its attenuation in the band of interest, normally in free space or with a transmission line, and by characterizing its complex permittivity and permeability.
- How is a module cleaned without damaging it?
A module is cleaned without damage by using low-hardness or demineralized water, soft tools and times of low irradiance, avoiding abrasives, harsh chemicals, thermal shock and excessive pressure, and following the manufacturer's instructions.
- How is a motor analyzed with an oscilloscope?
An oscilloscope lets you analyze a motor by observing its phase voltages and currents, the signals from sensors such as Hall effect sensors or encoders, and its behavior during startup, using suitable differential and current probes.
- How is a network analyzer calibrated with the SOLT method?
Four known standards (short, open, load and direct connection) are measured so that the analyzer can calculate the systematic errors of the instrument and cables and remove them mathematically from every subsequent measurement.
- How is a new cable verified before commissioning?
A new cable is verified by checking its physical condition, jacket integrity, insulation, continuity and phase sequence, and then applying the withstand test specified by the project.
- How is a passive harmonic filter designed in general terms?
A passive harmonic filter is a series LC circuit tuned close to the frequency to be removed. It offers that harmonic current a low-impedance path and keeps it from flowing into the grid.
- How is a photovoltaic system grounded?
By bonding all conductive metal parts into an equipotential system connected to an electrode, and deciding whether the DC side is grounded or operated isolated with insulation monitoring, according to the inverter design and the regulations.
- How is a point-to-point link aligned?
Direct line of sight with a clear Fresnel zone is ensured, the antennas are roughly pointed using geographic references, and each antenna is then fine-tuned in azimuth and elevation until the received signal is maximized, confirming that it is the main lobe.
- How is a point-to-point radio link validated?
Validating a point-to-point radio link means confirming that what is measured matches what was calculated: line of sight and clearance, received signal level, fade margin, signal quality and absence of interference.
- How Is a Polarity Test Performed?
The polarity test determines whether, at a given instant, the voltage induced in the secondary has the same direction as that of the primary or the opposite; it is done by comparing the voltage between terminals with a low applied voltage, or with a direct current kick.
- How Is a Power Amplifier Characterized in Its Linear Region?
Gain, matching and frequency response are measured with low-level signals, and a power sweep that locates the onset of compression determines up to what input level the gain remains constant.