How is a machine base verified?

A machine base is verified by checking that it is rigid and flat, that its anchors are firm and that it has no natural frequency close to running speed, through inspection, comparative vibration measurements and a soft foot check.

What is expected of a base

The base must support the machine without deforming, maintain alignment and not amplify vibration. A weak base acts like a spring: with insufficient stiffness, part of the rotor force is converted into movement of the structure, and if a natural frequency coincides with running speed, resonance appears.

What is checked

  • Anchors and bolts: tightness, condition and absence of corrosion.
  • Grout and contact: voids or cracks between the baseplate and the concrete.
  • Soft foot: one of the machine’s feet does not sit flat and distorts the frame when tightened.
  • Welds and structure: cracks and deformation in metal bases.
  • Piping and connections: stresses transmitted to the machine.

Soft foot check

With a dial indicator at each foot, loosen the bolts one at a time and observe how much the foot lifts. If the variation is appreciable, the machine was distorted, and this is corrected with shims or by machining the support.

Vibration measurements

  1. Measure on the machine and on the base, at the same points and in the same directions.
  2. A marked jump in amplitude between the foot and the base indicates looseness or poor contact.
  3. A phase difference between the two points also signals a loose support.
  4. An impact test or a startup and shutdown make it possible to locate natural frequencies.

How to interpret the result

On a sound base, the machine and the foundation move in phase and with amplitudes of the same order. If vibration worsens at a specific speed, suspect resonance and evaluate stiffening the base or changing the mass.