How is a link budget calculated?

The transmitted power and the antenna gains are added in decibels, and all the path losses, including free-space loss, are subtracted. The result is the received power, which is compared with the receiver sensitivity to obtain the margin.

The basic equation

A link budget is a power balance. Expressed in decibels, the received power is:

received power = transmitted power + transmitting antenna gain − transmit line losses + receiving antenna gain − receive line losses − path loss − other losses

Since all the terms are in decibels, the calculation comes down to adding and subtracting. Antennas contribute gain; lines, connectors, filters and mismatches contribute loss.

Free-space loss

This is the attenuation the wave undergoes as it spreads out in space. It grows with distance and with frequency: expressed in decibels, it is twenty times the logarithm of four pi times the distance divided by the wavelength. Doubling the distance adds about six decibels of loss, as does doubling the frequency, with antennas of constant gain. This formula assumes free space with no obstacles; in practice, other terms are added.

Other losses

  • Polarization mismatch and antenna mispointing.
  • Attenuation from rain, vegetation and atmospheric gases, more significant at high frequencies.
  • Partial obstruction of the Fresnel zone and reflections along the path.
  • Impedance mismatch at the ends.

From received level to margin

Receiver sensitivity is the minimum level the receiver needs to operate at the required quality. It depends on the receiver noise, calculated from thermal noise, bandwidth and noise figure, and on the signal-to-noise ratio required by the modulation. The margin is the difference between the received power and that sensitivity. Part of the margin is reserved for fading, the channel variations caused by weather and multipath, according to the desired availability.

An example of how to organize it

It is advisable to write the terms in a table with three columns: item, value and sign. First review the gains and losses that depend on the equipment, then those of the path, and obtain the received power. If the margin is insufficient, the levers are to increase antenna gain, reduce line losses by moving the equipment closer to the antenna, raise the power within what the regulations allow, use a lower-noise receiver or shorten the path.

Gain and loss values must come from measurements or verified datasheets, and radiated power limits must be consulted in the regulations applicable in the country of operation.