Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- Why does resonance occur between capacitors and the grid?
Resonance occurs between capacitors and the grid because the capacitance and the source inductance form a resonant circuit; at its frequency, the impedance seen by harmonic-producing loads becomes very high, and harmonic currents and voltages are amplified.
- Why Does Speed Drop on a Saturated Network?
On a saturated wireless network speed drops because the channel is a shared resource: each transmission takes up airtime, and with more users, more collisions and more retransmissions, less useful time is left for each one.
- Why does sunlight degrade a dielectric glove?
Sunlight degrades a dielectric glove because ultraviolet radiation and ozone break and rearrange the polymer chains, hardening the rubber and creating microcracks that reduce its insulating and mechanical capacity.
- Why Does the Analyzer Show a Noisy Trace?
Usually because the signal is close to the instrument's noise floor or because the resolution and video filters are too wide. Narrowing them, averaging or lowering the input attenuation usually cleans up the trace.
- Why Does the Insulation of a Motor Fed by a Variable Frequency Drive Fail?
Drives apply voltage pulses with very fast edges to the motor; on long cables, reflections raise the voltage at the terminals and concentrate the stress in the first turns of the winding, eventually causing partial discharges and insulation failure.
- Why does the neutral overheat in buildings with many switch-mode power supplies?
The neutral overheats in buildings with many switch-mode power supplies because the third harmonic and its odd multiples from each phase add up in the neutral instead of canceling, and the neutral current can exceed the phase current.
- Why does the probe load the circuit under test?
The probe loads the circuit because it adds its resistance, its capacitance and the inductance of its ground connection in parallel; at low frequency the resistance is what counts, and at high frequency the capacitance dominates.
- Why does the same oil sample give different results between laboratories?
The same oil sample gives different results between laboratories, in most cases, because the sample changed between one analysis and the other (water, gases, particles) or because the test methods and conditions are not identical. The uncertainty inherent in the method explains the rest.
- Why does thermography of a closed panel underestimate the actual temperature?
Thermography of a closed panel underestimates the actual temperature because the camera measures radiation from the outer surface, which is cooler than the internal component; the cover or door attenuates the heat and can block infrared radiation.
- Why does transformer oil darken?
Oil darkens because it oxidizes and becomes contaminated with heat and time: degradation products, sludge, and light-absorbing particles appear, and sometimes carbon from an internal fault.
- Why Does Wet Insulation Give Low Readings?
Wet insulation gives low readings because water, and above all the ions dissolved in it, opens conduction paths within and on the insulation, increasing the leakage current.
- Why Does Winding Insulation Paper Deteriorate?
Insulation paper deteriorates mainly because of temperature, moisture and oxygen: the cellulose chains break, the paper loses mechanical strength and releases water, acids and gases, and the damage is irreversible.
- Why is a channel input damaged by overvoltage?
A channel input is damaged when the voltage, energy or current of an overvoltage exceeds what the input protection can withstand, especially on the low-impedance input and on a direct connection without an attenuating probe.
- Why Is Coverage Lost After a Cable Change?
When coverage is lost after a cable change, the cause is almost always higher attenuation, faulty connectors or adapters, an impedance mismatch or a cable type unsuited to the frequency and length, and not the antenna itself.
- Why is ground grid continuity lost over time?
Because buried conductors and joints are exposed to corrosion, mechanical stress and thermal cycling, and the weakest connection is the one that eventually opens while the rest of the grid appears to be fine.
- Why is hot work dangerous in a tank?
Hot work is dangerous in a tank because heat, sparks or flame can ignite residual vapors in an enclosed space, and because welding consumes oxygen or generates toxic fumes in an unventilated enclosure.
- Why Is There Ripple in a Return Loss Measurement?
Ripple appears when two or more discontinuities reflect part of the signal and those reflections add or subtract depending on frequency. A calibration with residual directivity also produces it.
- Why is there vibration at twice line frequency in motors?
Vibration at twice line frequency in a motor comes from the magnetic forces between stator and rotor, which depend on the square of the field and therefore repeat twice per cycle of the power supply.
- Why overpressure damages a pressure sensor
A pressure sensor is damaged when the fluid deforms it beyond its elastic limit: the diaphragm stretches permanently or fractures, and the zero or the sensitivity is left altered.
- Wireless Mesh or Point-to-Multipoint Network?
A mesh network forwards traffic through the nodes themselves and adapts to obstacles and failures, while a point-to-multipoint network connects all nodes to a central station, which is simpler and has more predictable latency but creates a single point of dependency.