Troubleshooting

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Component-level or module-level repair?

    Component-level repair restores the damaged part on the board; module-level repair replaces the complete assembly. The decision balances cost, availability, downtime and confidence in the result.

  • Corrective, preventive or predictive maintenance?

    Corrective maintenance repairs after the failure, preventive maintenance intervenes by calendar or usage, and predictive maintenance intervenes according to the measured condition of the equipment; the choice depends on how it fails and how much failure costs.

  • Destructive or nondestructive failure analysis?

    Destructive analysis opens, cuts or alters the part to see inside it; nondestructive analysis examines it without damaging it. Start with nondestructive analysis and move to destructive analysis only when there is nothing more to learn without it.

  • How do you diagnose a circuit board that resets itself?

    A circuit board that resets itself usually has a power, clock or watchdog problem, or a noise or heat problem. The diagnosis consists of capturing the instant of the reset and determining which line or event precedes it.

  • How do you diagnose a motor that trips its protection?

    A motor that trips its protection is diagnosed by determining which type of protection is operating (overload, short circuit, ground fault or imbalance) and comparing the actual current with the rated current, the condition of the insulation and the mechanical condition of the load.

  • How do you diagnose a power supply that will not turn on?

    To diagnose a power supply that will not turn on, check the input, the protection, the rectification, the control stage and the outputs in that order, separating a supply that is actually damaged from one that is protecting itself against a shorted load.

  • How do you diagnose a variable frequency drive with a recurring fault?

    A drive with a recurring fault is diagnosed by first reading the fault code and event history, then checking that fault against the input supply, the motor load, the environment and the configuration, because the cause almost always lies outside the electronics themselves.

  • How do you isolate a fault in a circuit by bisection?

    Isolating a fault by bisection consists of dividing the circuit into two halves, measuring at the midpoint to find out which half contains the defect, and repeating with that half until it is located.

  • How is a failure documented to prevent recurrence?

    A failure is documented in a way that prevents recurrence when the record allows another person to understand what happened, why it happened and what was changed, with enough evidence to verify the correction.

  • How is a failure knowledge base built?

    A failure knowledge base is a structured, searchable record of symptoms, causes and solutions that turns individual experience into knowledge the team can reuse.

  • How is a failure modes and effects analysis performed?

    A failure modes and effects analysis goes through each element of a design, lists how it can fail, what effect that has and how severe it is, and prioritizes the actions needed to reduce the risk.

  • How is a power semiconductor tested out of circuit?

    A power semiconductor is tested out of circuit with the multimeter’s diode mode and, for a more complete check, with a curve tracer that shows its behavior under voltage.

  • How is a suspect capacitor checked?

    A suspect capacitor is checked by visual inspection and by measuring capacitance and equivalent series resistance, ideally out of circuit and discharged, because an ordinary multimeter does not detect all defects.

  • How is a suspect winding checked?

    A suspect winding is checked by comparing its resistance, its insulation to ground and its balance between phases with reference values, always with the equipment de-energized and disconnected.

  • How is abnormal current draw on a circuit board measured?

    Abnormal current draw on a board is measured with an ammeter in series with the power supply, or with a shunt resistor and oscilloscope, and compared with the draw of a healthy board.

  • How is an Ishikawa diagram used for an electrical failure?

    An Ishikawa diagram organizes the possible causes of an electrical failure into categories, like a fish skeleton, so they can be reviewed systematically instead of settling for the first idea.

  • How is component temperature measured to locate a defect?

    Measuring component temperature helps locate a defect because almost every electrical failure changes the power dissipated, and local heat points to the element dissipating more or less than normal.

  • How is step-by-step fault diagnosis structured?

    Orderly fault diagnosis moves from the general to the particular: describe the symptom, gather data without altering the equipment, form hypotheses, test them one by one and confirm the correction.

  • How is the five whys technique applied?

    The five whys technique consists of asking “why?” repeatedly, each time about the previous answer, until reaching a cause that can be acted on.

  • How is the signal on a line measured to detect an intermittent fault?

    To detect an intermittent fault on a line, the signal is recorded continuously or with event triggering, so that the instrument captures the anomaly when it occurs even if nobody is watching.

  • On-site or laboratory diagnosis?

    On-site diagnosis sees the equipment in its real environment and avoids transporting it; laboratory diagnosis offers control, instruments and repeatable conditions. The failure and the conditions in which it appears decide which is better.

  • Repair or replace failed equipment?

    Repair when the cause of the failure is understood, the equipment can return to safe and reliable performance, and the total cost is reasonable given its remaining service life; replace when any of those conditions is not met.

  • What are a failure mode and its effect?

    The failure mode is the way in which a component or function stops fulfilling its purpose; the effect is the consequence of that failure for the system and for the person using it.

  • What does “functional failure” mean?

    A functional failure is the loss of an item's ability to perform a function at the level of performance expected of it, even though it remains physically intact. It is defined by what the equipment can no longer do, not by which component broke.

  • What does “single point of failure” mean?

    A single point of failure is a component, connection or service whose failure alone stops the entire system because there is no backup or alternative path to replace it.

  • What does IEC 61025 set out on fault trees?

    IEC 61025 is an international standard that describes fault tree analysis: how to build the tree, which symbols to use and how to evaluate it qualitatively and quantitatively.

  • What does IEC 62740 set out on root cause analysis?

    IEC 62740 is an international standard that describes root cause analysis: its phases, how to choose the right techniques and how to document and follow up on the conclusions.

  • What does IEEE 493 compile on industrial system reliability?

    IEEE 493 is a recommended practice that brings together methods and data for designing and evaluating the reliability of industrial and commercial electrical systems.

  • What does ISO 14224 compile on reliability data?

    ISO 14224 establishes a common way of collecting and exchanging equipment reliability and maintenance data, with a taxonomy and uniform definitions of failures, causes and mechanisms.

  • What guidance does IEC 60812 give on failure mode analysis?

    IEC 60812 is an international standard that gives guidance on how to plan and apply failure modes and effects analysis, and its variant with criticality, to systems, products and processes.