24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • AC or DC for an Applied Voltage Test?

    AC voltage reproduces service stress but requires a source that can supply the capacitive current; DC requires a small source and measures leakage, although it distributes the field differently.

  • Accelerated life test or test under real conditions?

    An accelerated test obtains results in less time by raising stresses, while a test under real conditions is more faithful but slow. The choice depends on whether the failure mechanism is preserved when accelerating.

  • Acceleration, velocity or displacement: which should you measure?

    It depends on the frequency of the problem: displacement emphasizes low frequencies, acceleration emphasizes high frequencies and velocity gives a balanced view, which is why it is usually the best measure of a machine's overall severity.

  • Air-Insulated or Gas-Insulated Switchgear?

    Air-insulated switchgear uses air as the insulation between live parts, so it needs more space; gas-insulated switchgear encloses the live parts in sealed compartments with a gas of higher dielectric strength and is much more compact.

  • Airline respirator or self-contained breathing apparatus?

    An airline respirator offers practically unlimited duration and lower weight, but it ties the person to a hose and a source; self-contained apparatus offers freedom of movement, but with limited air and a heavier load. The choice depends on distance, duration and hazard.

  • Analog pressure gauge or digital transmitter: which is the right choice

    An analog pressure gauge serves for local indication without power; a digital transmitter serves when the pressure must reach a control system, a record or an alarm. The choice depends on who needs the data and where.

  • Anechoic Chamber or Open-Area Test Site?

    An anechoic chamber offers a controlled environment protected from external noise and weather, while an open-area site allows large equipment to be measured with a known ground reflection but exposes the measurement to ambient noise.

  • Arc flash face shield or full hood?

    An arc flash face shield protects the face and eyes with a shield and usually needs additional protection for the neck and head; a full hood covers the head, neck and face in a single piece and is the option for higher energy levels.

  • Arc-rated clothing or ordinary flame-resistant clothing?

    Arc-rated clothing is designed and tested to limit heat transfer from an electric arc and not to sustain combustion; ordinary flame-resistant clothing resists flame, but it has not been shown to protect against the energy of an arc.

  • Attenuating probe or unity-ratio probe?

    An attenuating probe reduces the signal by a factor, usually ten, and in exchange increases input resistance, reduces capacitive loading and extends the voltage range; a unity-ratio probe does not attenuate, so it reads small signals with a better signal-to-noise ratio, but it loads the circuit more and has less bandwidth.

  • Benchtop oscilloscope or portable oscilloscope with isolation?

    A benchtop oscilloscope offers more bandwidth, resolution and features, but its inputs share a common ground reference; an isolated portable model can measure floating circuits with channels isolated from each other and from ground, at the cost of less bandwidth.

  • Calibration or Adjustment: Are They the Same?

    They are not the same: calibration compares the instrument with a standard and documents its error; adjustment modifies the instrument to reduce that error. You can calibrate without adjusting, and adjust without having validly calibrated.

  • Calibration or Verification: Which Do You Need?

    Calibration is needed when you must know the instrument's error with its uncertainty and establish traceability; verification is enough when you only need to confirm that it meets a requirement, without rigorously quantifying the error.

  • Catalytic or infrared sensor for combustible gases?

    A catalytic sensor detects combustibles by burning them on a hot element and needs oxygen; an infrared sensor measures light absorption by hydrocarbons, does not depend on oxygen and is not poisoned, but it does not detect hydrogen. Each suits different gases and conditions.

  • Central inverter or string inverters?

    The difference is one of architecture: a central inverter concentrates the conversion of many modules in one large unit, while string inverters spread the conversion across several smaller units. Each option changes redundancy, maximum power tracking and maintenance.

  • Chamber test or field test?

    It depends on the question you want to answer: an environmental chamber isolates and repeats a controlled condition, while a field test shows how the equipment behaves with all the real conditions combined.

  • Charging at home or at a public station?

    Home charging is slower and cheaper to install and happens while the vehicle is parked; public charging offers higher power and availability away from home, with more variables of access, communication and compatibility.

  • Coaxial Cable or Waveguide?

    Coax is the practical, broadband option from DC up to very high frequencies; waveguide wins when lower loss or more power is needed at microwave frequencies, at the cost of limited bandwidth, rigidity and size.

  • Comparison Calibration or Direct Calibration?

    In direct calibration, the instrument measures or generates a value that is immediately compared with a standard; in comparison calibration, both receive the same quantity at the same time and their indications are compared, with no need to apply an exact known value.

  • Component-level or module-level repair?

    Component-level repair restores the damaged part on the board; module-level repair replaces the complete assembly. The decision balances cost, availability, downtime and confidence in the result.

  • Constant humidity or cyclic humidity?

    Constant humidity evaluates the effect of a stable humid atmosphere over a long period; cyclic humidity alternates temperature and humidity to cause condensation and enclosure breathing, and is more severe for many products.

  • Contact or non-contact detector?

    A contact detector measures or indicates voltage by connecting directly to the conductor and can reliably confirm its absence; a non-contact detector senses the electric field from a distance, which is fast but can miss voltage that is present.

  • Contact or non-contact electrode measurement?

    With contact electrodes, the sample is measured between plates or resting on a probe, which is simple and sensitive but exposed to air gaps; non-contact measurement uses a field through air or free space, avoiding any alteration of the sample but with lower accuracy.

  • Continuous or cyclic salt spray?

    Continuous salt spray keeps the exposure constant and is used for control and comparison; cyclic salt spray alternates fog, drying and humidity and better reproduces real atmospheric corrosion.

  • Continuous or route-based monitoring?

    Continuous monitoring records vibration permanently with fixed sensors and is the better choice for critical or rapidly deteriorating machines, while route-based monitoring measures at intervals with a portable collector and is sufficient for machines with slow-developing faults.

  • Copper or clad steel electrode?

    Copper offers greater corrosion resistance and good conductivity but costs more and is soft; copper-clad steel combines mechanical strength with copper at the surface, and its life depends on the cladding remaining intact.

  • Corrective, preventive or predictive maintenance?

    Corrective maintenance repairs after the failure, preventive maintenance intervenes by calendar or usage, and predictive maintenance intervenes according to the measured condition of the equipment; the choice depends on how it fails and how much failure costs.

  • DC or Very Low Frequency Testing on Cables?

    For extruded medium-voltage cables, very low frequency is usually preferred over direct current, because it distributes the field as in service and avoids the space charge that DC leaves in the insulation.

  • Destructive or nondestructive failure analysis?

    Destructive analysis opens, cuts or alters the part to see inside it; nondestructive analysis examines it without damaging it. Start with nondestructive analysis and move to destructive analysis only when there is nothing more to learn without it.

  • Diagnostic Test or Pass/Fail Test?

    A pass/fail test confirms that the insulation withstands a defined stress level; a diagnostic test measures parameters that describe its condition and makes it possible to follow its evolution.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer