24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Electrical safety and PPE

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Arc flash face shield or full hood?

    An arc flash face shield protects the face and eyes with a shield and usually needs additional protection for the neck and head; a full hood covers the head, neck and face in a single piece and is the option for higher energy levels.

  • Arc-rated clothing or ordinary flame-resistant clothing?

    Arc-rated clothing is designed and tested to limit heat transfer from an electric arc and not to sustain combustion; ordinary flame-resistant clothing resists flame, but it has not been shown to protect against the energy of an arc.

  • Contact or non-contact detector?

    A contact detector measures or indicates voltage by connecting directly to the conductor and can reliably confirm its absence; a non-contact detector senses the electric field from a distance, which is fast but can miss voltage that is present.

  • How are non-electrical personnel trained in basic risks?

    Non-electrical personnel are not taught to work on installations but to recognize the hazard, stay away from it and report it: what electricity does to the body, which signs indicate risk and which tasks are never theirs to do.

  • How does a ground-fault circuit interrupter for personnel protection work?

    A ground-fault circuit interrupter for personnel protection compares the current leaving on the phase conductor with the current returning on the neutral; if a difference of a few milliamperes takes another path, it opens the circuit in a fraction of a second.

  • How does a non-contact voltage detector work?

    A non-contact voltage detector senses the alternating electric field around an energized conductor through an internal antenna and converts it into a light or sound indication, without needing a closed circuit with the conductor.

  • How does an arc flash face shield protect the wearer?

    An arc flash face shield protects the face, eyes and neck with a transparent shield that absorbs or blocks part of the radiation and heat, and that withstands the impact of particles and the pressure of the event.

  • How is a clearance prepared on a medium-voltage line?

    A clearance on a medium-voltage line is prepared by opening and isolating the line, locking it out, verifying the absence of voltage, grounding and short-circuiting it and marking off the zone, all under a document that transfers responsibility to a work supervisor.

  • How is a live work procedure established?

    A live work procedure is established only when de-energizing is impossible or unacceptable, and it includes justification, risk analysis, qualified personnel, a specific method and tools, safety distances and an emergency plan.

  • How is a voltage detector checked before use?

    A voltage detector is checked before each use by confirming its physical condition, its self-test if it has one and its response on a known source, to be sure that it would indicate voltage if voltage were present.

  • How is a work crew prepared for substation switching?

    A work crew is prepared for substation switching by defining roles and authority, reviewing the procedure and diagrams, checking equipment and protection, agreeing on communication and planning for emergencies before entering the site.

  • How is an arc flash study performed?

    An arc flash study models how much energy an arc would release at each point in an installation, using system data and protective device trip times, in order to define approach boundaries, protective equipment and improvements.

  • How is energy lockout/tagout performed?

    Energy lockout/tagout consists of isolating all of a machine's energy sources, fitting a device that prevents re-energizing it, identifying it with a tag and confirming that it is actually de-energized before work begins.

  • How is leakage current measured in portable equipment?

    Leakage current in portable equipment is measured with the equipment connected and running under controlled conditions, using an instrument that records the current flowing to ground or to accessible parts, to confirm that it poses no risk to the user.

  • How is PPE inspected before use?

    Personal protective equipment is inspected before each use by comparing its condition with what its function demands: look for visible damage, contamination, deformation or expired service life, and remove anything doubtful from service.

  • How is risk assessed in an old electrical panel?

    Risk in an old panel is assessed by comparing what the equipment can withstand with what the system demands of it today: interrupting rating against available short-circuit current, physical condition of connections and insulation, and arc incident energy.

  • How is the absence of voltage verified before starting work?

    The absence of voltage is verified by testing a suitable instrument on a known source, measuring on every conductor that will be touched and then testing the instrument again, because a single no-voltage result may be due to a faulty instrument.

  • How is the available fault current at a panel measured?

    The available fault current at a panel is normally obtained by short-circuit calculation using system data; in the field it can only be estimated, for example by measuring loop impedance, and that estimate does not include all contributions.

  • How is the condition of an insulating mat checked?

    An insulating mat is checked by visual and tactile inspection of its entire surface, confirming cleanliness, flexibility, uniform thickness and marking, and by periodic dielectric tests defined by the manufacturer and the applicable regulations.

  • How is the insulation resistance of an insulated tool measured?

    The insulation resistance of an insulated tool is measured by applying a DC test voltage between the conductive part and the insulating coating and confirming that the leakage current is so small that the resistance comes out very high.

  • How is touch voltage measured on a metal enclosure?

    Touch voltage on a metal enclosure is measured between the enclosure and a reference point representing the floor where a person's feet stand, using an instrument with an impedance comparable to that of the human body, because the result from an ordinary voltmeter can be misleading.

  • How should insulating gloves be cared for and stored?

    Insulating gloves are kept clean, dry and free of folds, away from sunlight, heat, ozone, oils and sharp objects, and are stored in a suitable container that keeps them in their natural shape.

  • How should you respond to an electrical accident?

    In an electrical accident the first priority is not to become another victim: cut the power or separate the person using insulating means, call for emergency help, assess breathing and pulse and begin resuscitation if needed.

  • Leather glove over a dielectric glove: when is it necessary?

    The leather glove is worn over the dielectric glove to protect it from cuts, abrasion and mechanical punctures, because insulating rubber is thin and vulnerable; leather on its own does not insulate.

  • Live work or de-energized work?

    De-energized work is the rule because it eliminates the hazard at its root; live work is accepted only as a justified exception, with a specific method, tools and qualified personnel, because the risk depends on nothing going wrong.

  • What common mistakes occur when verifying zero voltage?

    The main mistakes when verifying zero voltage are trusting an unchecked instrument, measuring only one combination of conductors, using a non-contact detector as definitive proof, and confusing an induced voltage with a true absence of voltage or the other way around.

  • What does “energized” versus “de-energized” mean?

    Equipment is energized when it is connected to a voltage source or could be, even if it is switched off; it is de-energized only when it has been isolated from all sources, locked out, verified free of voltage and its stored energy discharged.

  • What does “qualified personnel” mean?

    “Qualified personnel” means a person who, through training, knowledge and experience, recognizes the electrical hazards of a specific task and knows how to control them, and who has also been authorized by the employer to perform it.

  • What does ASTM F1506 measure for arc-resistant textiles?

    ASTM F1506 is a performance specification for textiles used in clothing for electrical workers. It measures their flame resistance and arc rating, that is, how much arc energy they withstand before the heat transmitted reaches the skin in a harmful way.

  • What does NOM-017-STPS require for personal protective equipment?

    NOM-017-STPS sets the requirements for selecting, using and handling personal protective equipment in workplaces, based on a risk analysis and on the fact that other control measures do not fully eliminate the hazard.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer