- Acceleration, velocity or displacement: which should you measure?
It depends on the frequency of the problem: displacement emphasizes low frequencies, acceleration emphasizes high frequencies and velocity gives a balanced view, which is why it is usually the best measure of a machine's overall severity.
- Continuous or route-based monitoring?
Continuous monitoring records vibration permanently with fixed sensors and is the better choice for critical or rapidly deteriorating machines, while route-based monitoring measures at intervals with a portable collector and is sufficient for machines with slow-developing faults.
- Handheld vibration meter or full analyzer?
A handheld vibration meter gives an overall vibration level to detect whether a machine is within normal limits, while a full analyzer shows the spectrum and waveform to reveal why it vibrates; the choice depends on whether you need to monitor or to diagnose.
- How are two shafts aligned with a laser?
A laser emitter and receiver are attached to the two shafts, the shafts are rotated, and the parallel offset and angle are measured at the coupling plane; from those values the vertical and horizontal corrections for the movable machine are calculated.
- How does a piezoelectric accelerometer work?
A piezoelectric accelerometer works because a piezoelectric crystal or ceramic generates an electric charge proportional to the force it receives, and that force comes from a seismic mass that compresses the material as it accelerates with the base.
- How is a fault diagnosed by combining vibration and temperature?
The two variables are combined because they measure different consequences of the same defect: vibration reveals abnormal dynamic forces and temperature reveals energy dissipated as heat, and only together do they distinguish between similar causes.
- How is a gear reducer evaluated?
A gear reducer is evaluated by combining vibration analysis, oil review, temperature and inspection, because gearing leaves its main signature at the gear mesh frequency and its sidebands, which are read in the spectrum.
- How is a machine base verified?
A machine base is verified by checking that it is rigid and flat, that its anchors are firm and that it has no natural frequency close to running speed, through inspection, comparative vibration measurements and a soft foot check.
- How is a rotor balanced in the field?
The 1X vibration is measured with its phase, a known trial mass is added at a defined angle, the change is measured, and from it the correction mass and angle are calculated, then installed and verified.
- How is a vibration alarm level defined?
It is defined by combining severity criteria by machine type with the machine's own baseline, setting at least one alert level and one danger level, which are adjusted with experience to limit false alarms.
- How is a vibration monitoring route set up?
You define which machines to measure, at which points and in which directions, with which parameters and how often, so that each round repeats the same measurements under the same conditions and the data are comparable over time.
- How is a wind turbine monitored?
A wind turbine is monitored by measuring vibration at its bearings, gearbox and main components, with fixed sensors and analysis that takes into account that speed and load change constantly with the wind.
- How is acceleration measured on a test bench?
On a test bench, acceleration is measured with an accelerometer rigidly attached to the part or to the test table, measuring both control and response, because acceleration is directly linked to the force the specimen undergoes.
- How is an impact test performed to find natural frequencies?
The structure is struck with an instrumented hammer while an accelerometer records the response; the ratio of response to force, as a function of frequency, shows peaks at the natural frequencies.
- How is envelope analysis performed for bearings?
The vibration signal is filtered in a high-frequency band where the defect impacts excite resonances, the envelope of that signal is obtained, and its spectrum is calculated, in which the defect repetition frequencies appear.
- How is relative shaft vibration measured?
Relative shaft vibration is measured with proximity sensors that do not touch the shaft and that record its motion relative to the casing or bearing on which they are mounted, something an accelerometer on the casing does not see as clearly.
- How is rotational speed measured with a tachometer?
A tachometer measures rotational speed by counting how many times per unit of time a mark or reflection passes its sensor, or by measuring the linear speed of a surface in contact, and it expresses the result in revolutions per minute.
- How is shaft displacement measured?
Shaft displacement is measured with non-contact proximity sensors, which convert the distance between the sensor tip and the metal surface of the shaft into an electrical signal, both for its average position and for its vibratory motion.
- How is the vibration of a structure evaluated?
The vibration of a structure is evaluated by measuring the response with accelerometers sensitive at low frequency, identifying its natural frequencies and comparing the levels with the comfort, damage or operating criteria that apply to the case.
- How is triaxial vibration measured?
Triaxial vibration is measured with a three-axis accelerometer or with three sensors oriented in orthogonal directions, which makes it possible to record vibration in all three spatial directions at a single point and at the same time.
- How is vibration measured on a bearing housing?
Housing vibration is measured by attaching a transducer, normally an accelerometer, as close as possible to the bearing load zone and in the relevant directions, because the housing is the path by which the defect signal arrives.
- How is vibration monitored in a centrifugal pump?
Vibration in a centrifugal pump is monitored by measuring at the motor and pump bearings, in the radial and axial directions, on a fixed routine and with the machine in comparable operating conditions, in order to watch the trend and detect faults.
- Non-contact sensor or accelerometer?
The non-contact sensor measures the motion of the shaft relative to the support, and the accelerometer measures the absolute vibration of the casing; the former is chosen when the shaft moves freely within its bearings and the latter when the casing transmits vibration well.
- Stud, adhesive or magnet mounting?
A stud gives the stiffest attachment and the widest frequency band, adhesive is a good alternative when drilling is not possible, and a magnet is the most practical option but limits the usable range at high frequencies.
- What are natural frequency and resonance?
The natural frequency is the frequency at which a structure oscillates freely after an impulse, and resonance occurs when a periodic force excites it at that frequency, so that the vibration is amplified significantly.
- What are sidebands in a spectrum?
They are peaks that appear on either side of a center frequency, separated from it by a modulating frequency, and they reveal that this component is being amplitude-modulated by another repetitive phenomenon.
- What causes cavitation vibration in pumps?
Cavitation in a pump produces vibration because the liquid vaporizes in low-pressure zones and the bubbles collapse violently on reaching higher-pressure zones, generating impacts that excite the pump with broadband noise.
- What causes vibration in electric motors from broken rotor bars?
Broken bars in the rotor of an induction motor distort the magnetic field and the current, which produces sidebands around the line frequency in the current and variations in the vibration, with modulation at the pole pass frequency.
- What does “waterfall” mean in vibration analysis?
In vibration analysis, a waterfall is a three-dimensional display that stacks successive spectra to show how frequencies and amplitudes change with time or with machine speed.
- What does ISO 18436-2 cover on analyst certification?
ISO 18436-2 defines the competence requirements and the assessment and certification criteria for personnel who perform machine condition monitoring and diagnostics using vibration, organized in categories according to level of responsibility.