Oscilloscopes

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Attenuating probe or unity-ratio probe?

    An attenuating probe reduces the signal by a factor, usually ten, and in exchange increases input resistance, reduces capacitive loading and extends the voltage range; a unity-ratio probe does not attenuate, so it reads small signals with a better signal-to-noise ratio, but it loads the circuit more and has less bandwidth.

  • Benchtop oscilloscope or portable oscilloscope with isolation?

    A benchtop oscilloscope offers more bandwidth, resolution and features, but its inputs share a common ground reference; an isolated portable model can measure floating circuits with channels isolated from each other and from ground, at the cost of less bandwidth.

  • Differential probe or two channels with math subtraction?

    A differential probe rejects common mode with electronics designed for that purpose, whereas two channels with math subtraction depend on both channels and probes being perfectly matched; they are only justified for low-frequency signals with little common mode.

  • Digital or analog oscilloscope?

    Today a digital oscilloscope is the usual choice because it stores, shows what precedes the trigger and measures; an analog one shows the signal in real time without digitizing it, and it remains useful when intensity variation or immediate response matters.

  • How do you capture a single, sporadic event?

    Configure the oscilloscope to arm a trigger that identifies the event, with enough sample rate and memory to see its detail and context, and leave it waiting in normal or single mode until it occurs.

  • How do you compensate a passive probe?

    Connect the probe to the oscilloscope's square-wave calibration signal and adjust the probe's compensation capacitor until the edges of the wave look straight, with no rounding or overshoot.

  • How do you debug a serial bus with decoding?

    To debug a serial bus with decoding, the oscilloscope interprets the signal levels as bits according to the protocol and displays addresses and data over the waveform, which makes it possible to relate the content to the electrical signal.

  • How do you find an intermittent fault with an oscilloscope?

    To find an intermittent fault, configure the oscilloscope to capture only the abnormal event, with a selective trigger, long memory and persistence or segmented modes, and leave it recording until the event occurs.

  • How do you make a floating measurement with an oscilloscope?

    A floating measurement is one in which no point in the circuit is referenced to ground. It is made with a differential probe or an oscilloscope with isolated channels, and not by disconnecting the instrument's ground, which is a dangerous practice.

  • How do you measure current in a conductor without opening the circuit?

    To measure current without opening the circuit, a clamp-on current probe is used that measures the magnetic field around a single conductor, so the circuit remains intact and insertion is minimal.

  • How do you measure dead time in a power inverter?

    The dead time of an inverter is the interval during which both switches in the same leg are off; it is measured by comparing the gate signals of both with probes that tolerate the floating reference of the high-side switch.

  • How do you measure instantaneous power with voltage and current?

    Instantaneous power is the product of voltage and current at each instant; the oscilloscope calculates it by multiplying two channels, provided the two signals are aligned in time.

  • How do you measure overshoot and settling?

    Overshoot is how far the peak exceeds the final value of a transition, expressed as a percentage of the step amplitude, and settling is the time the signal takes to remain within a tolerance band around that final value.

  • How do you measure the noise and ripple of a power supply?

    Power supply noise and ripple are measured with AC coupling, a minimal ground connection and a defined bandwidth, because the result depends more on how the probe is connected than on the instrument.

  • How do you measure the phase shift between two signals?

    The phase shift between two signals is obtained by measuring the time delay between equivalent points on both and dividing it by the period: the phase shift in degrees is 360 times that quotient.

  • How do you safely measure a power signal with an oscilloscope?

    Use a probe suited to the voltage and the measurement category, normally a differential probe, with the oscilloscope properly grounded and without ever defeating the protective connection, and have the work done by qualified personnel.

  • How do you set up a pulse width trigger?

    A pulse width trigger makes the oscilloscope capture only when a pulse lasts less than, more than or exactly a defined time, which makes it possible to isolate defective pulses among many correct ones.

  • How do you use a mask test on an oscilloscope?

    A mask test defines forbidden regions around a waveform or eye diagram and has the oscilloscope acquire many waveforms, counting how many violate the mask to give a pass or fail result.

  • How do you use the average function to reduce noise?

    The average function sums many acquisitions of a repetitive signal and calculates their mean; uncorrelated random noise is reduced, and the signal that repeats on every trigger remains.

  • How does a current probe work?

    A current probe measures the magnetic field produced by the current in a conductor and delivers a proportional voltage, without interrupting the circuit, combining a Hall sensor for DC and low frequency with a transformer for the AC part.

  • How is a Hall effect sensor verified?

    A Hall effect sensor is verified by powering it according to its datasheet, applying a known magnetic field or moving a magnet, and using the oscilloscope to confirm that its output changes level, or varies proportionally, at the expected points and with the expected cleanliness.

  • How is a motor analyzed with an oscilloscope?

    An oscilloscope lets you analyze a motor by observing its phase voltages and currents, the signals from sensors such as Hall effect sensors or encoders, and its behavior during startup, using suitable differential and current probes.

  • How is an oscilloscope used to debug a switching converter?

    To debug a switching converter, the oscilloscope is used to observe the switching node, the inductor current and the output, looking for overshoot, ringing, noise and behavior that changes with load.

  • How is signal integrity evaluated on a digital line?

    Signal integrity on a digital line is evaluated by observing, at the receiver, the edge shape, overshoot, ringing from reflections, noise and jitter, with a bandwidth and probe connection that do not distort what is being measured.

  • Logic analyzer or mixed-signal oscilloscope?

    Choose a mixed-signal oscilloscope when you need to see the analog waveform alongside a few digital lines; choose a logic analyzer when you need many lines, very deep memory or state analysis synchronized to a clock.

  • Sample rate: how it relates to bandwidth

    The sample rate must be several times higher than the oscilloscope's bandwidth. The theoretical minimum is twice the highest frequency in the signal, but real waveform reconstruction requires a larger margin.

  • What are vertical resolution and effective bits?

    Vertical resolution is the number of levels into which the oscilloscope's converter divides the voltage scale, according to its bits. Effective bits indicate how many of those bits are actually useful once noise and distortion are taken into account.

  • What causes an oscilloscope not to trigger stably?

    Unstable triggering occurs because the instrument does not always find the same condition in the signal: the level is outside the signal, the source or coupling is not appropriate, noise causes multiple crossings, or the signal has several similar events per period.

  • What does “pretrigger” mean?

    Pretrigger is the part of the capture that corresponds to the moments before the trigger event, and it is possible because a digital oscilloscope records continuously into a circular memory and keeps what happened beforehand.

  • What does the IEEE 1057 standard define for waveform recorders?

    The IEEE 1057 standard defines the terminology and test methods for characterizing digitizing waveform recorders, that is, instruments that convert an analog signal into a sequence of data, such as digital oscilloscopes and digitizers.