24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Wireless communications

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • How are channels planned to avoid interference?

    Channels are planned to avoid interference by assigning each transmitter a frequency that does not overlap with those of its neighbors, reusing frequencies only at sufficient distances or with sufficient isolation, and then verifying with measurements.

  • How does a vector signal analyzer work?

    A vector signal analyzer captures a radio frequency signal, converts it to in-phase and quadrature components, demodulates it in software and measures its quality, displaying the spectrum as well as the constellation and the modulation errors.

  • How is a point-to-point radio link validated?

    Validating a point-to-point radio link means confirming that what is measured matches what was calculated: line of sight and clearance, received signal level, fade margin, signal quality and absence of interference.

  • How is a spectrum survey performed to detect interference?

    A spectrum survey to detect interference consists of observing the band of interest with an analyzer, identifying the signals present, comparing them with those expected and locating the origin of those that should not be there.

  • How is a wireless channel characterized?

    Characterizing a wireless channel means measuring how propagation behaves between transmitter and receiver (loss, path delays, variation over time and noise) in order to know what modulation, antenna or margin the link requires.

  • How Is a Wireless Module Integrated into a Product?

    Integrating a wireless module into a product requires care with the antenna, power supply, board layout and regulation, because most performance failures originate in the integration and not in the module.

  • How Is a Wireless Network Deployed in a Plant with Metal Structures?

    To deploy a wireless network in a plant with metal structures, start from a measured site survey, not just from drawings, because metal reflects, blocks and changes propagation in ways that are hard to predict.

  • How is adjacent channel power measured?

    Adjacent channel power is measured by integrating the power in the transmitter's channel and in the neighboring channels with an analyzer, and it is expressed as the ratio between the two; it indicates how much energy spills outside the assigned channel.

  • How is an indoor coverage survey performed?

    An indoor coverage survey consists of measuring how the radio signal is distributed inside a building and comparing it with what the service needs, in order to find weak areas, interference and points where antennas should be installed or relocated.

  • How Is an Unauthorized Transmitter Identified?

    An unauthorized transmitter is identified by characterizing its signal with a spectrum analyzer, comparing it with what should exist in that band and locating it by direction of arrival and level variation.

  • How is channel occupancy over time measured?

    Channel occupancy over time is measured by observing, during a representative period, what fraction of the time the signal level exceeds a defined threshold, using an analyzer capable of gap-free capture or with adequate time resolution.

  • How is error vector magnitude measured?

    Error vector magnitude (EVM) measures, on a vector analyzer, how far the received symbols fall from their ideal positions in the constellation, and it is expressed as a proportion of the reference amplitude.

  • How is received signal strength measured?

    Received signal strength is measured with a calibrated receiver that indicates the power or voltage at its input, or with a field antenna of known response; the value depends on the antenna, the bandwidth and the calibration.

  • How is receiver sensitivity determined?

    The sensitivity of a receiver is the minimum signal it needs to reach a defined quality level, normally a given error rate; it is determined by reducing the level of a known signal until the quality just reaches that limit.

  • How is the coexistence of multiple radios in one device tested?

    The coexistence of multiple radios in one device is tested by operating the radios simultaneously and comparing the performance of each with its performance in isolation, to detect desensitization, mutual interference and loss of throughput.

  • How is the frequency error of a transmitter measured?

    The frequency error of a transmitter is measured by comparing its actual frequency with the nominal one using an instrument with a stable time base, and it is expressed in hertz or in parts per million relative to the center frequency.

  • How is transmitter output power measured?

    The output power of a transmitter is measured by connecting it, through a suitable attenuator, to a power meter or an analyzer, which integrates the power within the signal bandwidth, and correcting for the path losses.

  • How Is Wireless Communication Validated in a Vehicle?

    To validate wireless communication in a vehicle, the performance of the radio is measured as installed in the complete vehicle, in motion and in operation, because the body, the antenna and the vehicle's own electronics change the result.

  • How Is Wireless Telemetry of Electrical Variables Done?

    Wireless telemetry of electrical variables is achieved by measuring with transducers or meters at the point of interest and sending their data by radio to a concentrator, without the radio ever touching the power circuit.

  • Licensed or Unlicensed Band for an Industrial Link?

    A licensed band offers protection against interference and greater predictability, but with paperwork, cost and less flexibility; an unlicensed band is immediate and cheap, but shares the spectrum with other users, with no guarantee of quality.

  • Microwave Link or Fiber Optics?

    Fiber optics offers greater capacity, lower and stable latency and immunity to electromagnetic interference, but requires conduit; a microwave link deploys faster and clears obstacles without civil works, but depends on line of sight and weather.

  • Phase or Amplitude Modulation: What Is the Trade-Off?

    Modulating phase is more robust against amplitude noise and keeps power constant, while adding amplitude allows more bits per symbol to be transmitted, at the cost of requiring greater linearity and a better signal-to-noise ratio.

  • Short-Range or Long-Range Low-Power Wireless Communication?

    Short-range communication offers higher speed and lower latency over short distances, while long-range low-power communication sacrifices speed to reach far with very little consumption; the choice depends on distance, data volume and power supply.

  • What Causes Co-Channel Interference?

    Co-channel interference occurs when two or more transmitters use the same channel at the same time within range of each other, so that each receiver also receives the signal that was not meant for it.

  • What Causes Intermodulation at a Site with Several Transmitters?

    Intermodulation at a site with several transmitters appears when signals of different frequencies mix in a nonlinear element and generate new products that can fall in a receive channel.

  • What does “co-channel” mean?

    Co-channel describes two or more transmitters operating on the same frequency channel; the term is almost always used to refer to the interference they cause each other.

  • What Does EIRP Mean?

    EIRP is equivalent isotropic radiated power: the power that would have to be fed to an ideal isotropic antenna to produce, in the direction of maximum radiation, the same power density as the real antenna.

  • What Does the ETSI EN 300 328 Standard Cover?

    ETSI EN 300 328 is a European harmonized standard that sets spectrum and efficient channel use requirements for wideband transmission equipment in the 2.4 GHz band.

  • What Does the IEEE 802.11 Family Define in General?

    The IEEE 802.11 family defines how the devices of a wireless local area network communicate by radio: the physical layer, meaning modulation and channels, and medium access control, which governs who transmits and when.

  • What Does the IEEE 802.15.4 Standard Cover?

    IEEE 802.15.4 defines the physical layer and medium access control of low-rate, low-power, short-range wireless networks; it does not define the complete network or the application.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer