Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- How does an impedance meter for materials work?
An impedance meter for materials applies an AC signal of known frequency to a sample, measures the voltage and current with their phase relationship, and calculates the complex impedance, from which capacitance, losses, permittivity or permeability are obtained.
- How does an online gas monitor work?
An online gas monitor is installed on the transformer, continuously extracts gases from the oil through a membrane or a chamber, and measures them with sensors or a compact chromatograph to record how they evolve and raise an alert if they increase.
- How does an RTD temperature sensor work?
An RTD measures temperature by taking advantage of the fact that the electrical resistance of a metal, normally platinum, increases in a stable and repeatable way as temperature rises.
- How does instrument resolution enter into the uncertainty?
Instrument resolution enters the uncertainty as a Type B component with a rectangular distribution: its half-width is half the resolution, and the standard uncertainty is that half divided by the square root of three.
- How does power quality analysis help reduce Joule losses?
Power quality analysis reduces Joule losses by revealing the currents that do no useful work, such as harmonics, reactive current, and unbalance, which raise the RMS value of the current and with it the heating.
- How does power quality monitoring justify an investment?
Power quality monitoring is justified when its cost can be compared with what the downtime, damage, and losses it reveals are costing, and when it turns suspicions into data that support a decision.
- How Does Solid Insulation Age Under Electrical Stress?
Solid insulation ages under electrical stress through cumulative damage: partial discharges in voids erode the material, branching channels (trees) form, and the sound thickness shrinks until breakdown occurs.
- How does the permittivity of a polymer change with frequency?
The permittivity of a polymer decreases with frequency in steps, as the slower polarization mechanisms (dipolar and interfacial) stop following the field, and each step is accompanied by a dielectric loss peak.
- How does the resistance of a metal vary with temperature?
The electrical resistance of a metal increases with temperature almost linearly over a moderate range, because the greater agitation of the crystal lattice scatters the conduction electrons more.
- How Is a Battery Backup System Integrated in a Plant?
Integrating battery backup requires defining which load is backed up and for how long, choosing between a UPS and a DC system, and designing protection, ventilation and maintenance specific to the batteries.
- How is a battery characterized with an electronic load?
The battery is discharged with an electronic load at controlled current, power or resistance while voltage, current and time are logged, down to a defined voltage limit; from this you obtain the capacity, the discharge curve and the internal resistance.
- How is a battery cycle life test performed?
A cycle life test repeatedly charges and discharges a battery under defined conditions and measures how much capacity it retains over the cycles and how its resistance changes, until it reaches a predetermined end-of-life criterion.
- How is a cable shield grounded?
It depends on the frequency of the problem. For high frequencies, the shield must be connected to the enclosure with a 360-degree, low-inductance contact; at low frequency, with sensitive signals, it may be better to connect it at one end only to avoid ground loops.
- How is a camera focused for correct measurement?
Focus on the object to be measured until its edges look sharp, because poor focus mixes radiation from the background with radiation from the object and makes the measured temperature wrong.
- How is a cavity filter tuned with the analyzer?
By watching the reflection and transmission on the screen and adjusting the screws of each resonator until its response settles at the center frequency, and the coupling screws until the bandwidth and passband shape are achieved.
- How is a charging station verified before commissioning?
Before a charging station is energized, checks confirm that the installation is safe and that the equipment behaves as it should: inspection, ground continuity, insulation, protective devices, and a functional test that simulates the vehicle.
- How is a circuit board designed for EMC compliance?
It is designed by controlling three things: the return path of each current, the area of the loops they form and the speed of the edges. A continuous reference plane, close decoupling and filtering at the connectors solve most problems.
- How is a clearance prepared on a medium-voltage line?
A clearance on a medium-voltage line is prepared by opening and isolating the line, locking it out, verifying the absence of voltage, grounding and short-circuiting it and marking off the zone, all under a document that transfers responsibility to a work supervisor.
- How is a commissioning verification of a solar array performed?
A commissioning verification of a solar array confirms, before operation, that the installation matches the design, is safe and delivers what is expected: inspection, electrical tests, inverter startup and performance comparison.
- How is a communications port protected against discharges?
A communications port is protected against electrostatic discharge by diverting the discharge current to the chassis before it reaches the circuits, with a well-connected shield, suppressors close to the connector and a good grounding layout.
- How is a confined space isolated from energy sources and fluids?
A confined space is isolated by physically disconnecting it from every energy source and fluid that could activate or enter it, with lockout/tagout of energy and blind flanges or disconnection of piping, and by verifying that the isolation works.
- How is a confined space ventilated?
A confined space is ventilated by bringing in clean air and exhausting contaminated air so that the entire volume is renewed, placing the intake away from contamination sources, directing the flow to where people are and measuring to confirm the result.
- How Is a Conformal Coating Evaluated?
A conformal coating is evaluated by confirming that it covers continuously and uniformly, that it adheres, that it maintains its insulation under moisture and temperature, and that it protects against contamination and corrosion without damaging the circuit.
- How is a control chart used to monitor a working standard?
A control chart for a working standard periodically records the measurement of a stable check standard and compares each point with limits calculated from its own history, to detect drift, jumps or increases in spread between calibrations.
- How is a deep ground electrode installed?
A deep electrode is installed by drilling a borehole down to layers of lower resistivity, placing the electrode and backfilling so that it is in intimate contact with the soil and remains accessible for inspection.
- How is a digital multimeter calibrated in general terms?
A digital multimeter is calibrated by applying known signals, generated by a traceable calibrator or standard, on each selected function and range, and comparing the multimeter reading with the reference value to obtain the error and its uncertainty.
- How is a failure documented to prevent recurrence?
A failure is documented in a way that prevents recurrence when the record allows another person to understand what happened, why it happened and what was changed, with enough evidence to verify the correction.
- How is a failure knowledge base built?
A failure knowledge base is a structured, searchable record of symptoms, causes and solutions that turns individual experience into knowledge the team can reuse.
- How is a failure modes and effects analysis performed?
A failure modes and effects analysis goes through each element of a design, lists how it can fail, what effect that has and how severe it is, and prioritizes the actions needed to reduce the risk.
- How is a fall-of-potential measurement performed?
The fall-of-potential measurement injects current between the electrode under test and a distant auxiliary electrode, and measures the voltage against an intermediate probe that is moved to find the zone of stable value.