EMC/EMI

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Ferrite on the cable or filter at the input?

    A ferrite is a quick, inexpensive fix, useful for common mode on a specific cable; an input filter is an engineered solution that acts on both common mode and differential mode and protects the entire input. If a cable already has a problem, a ferrite lets you test; if you are designing, a filter is the right choice.

  • How does a reverberation chamber work?

    A reverberation chamber is a closed metal cavity with a mode stirrer that changes the field distribution; averaging over the stirrer positions yields a statistically uniform, isotropic field, which is used to test immunity or to measure total radiated power.

  • How is a cable shield grounded?

    It depends on the frequency of the problem. For high frequencies, the shield must be connected to the enclosure with a 360-degree, low-inductance contact; at low frequency, with sensitive signals, it may be better to connect it at one end only to avoid ground loops.

  • How is a circuit board designed for EMC compliance?

    It is designed by controlling three things: the return path of each current, the area of the loops they form and the speed of the edges. A continuous reference plane, close decoupling and filtering at the connectors solve most problems.

  • How is a communications port protected against discharges?

    A communications port is protected against electrostatic discharge by diverting the discharge current to the chassis before it reaches the circuits, with a well-connected shield, suppressors close to the connector and a good grounding layout.

  • How is a ferrite applied to a cable?

    The complete cable (all its conductors together) is passed through a ferrite core placed as close as possible to the source or exit point, choosing a material whose loss region matches the frequency of the problem. It acts on common mode, not on the useful signal.

  • How is a power input filtered?

    A filter is placed at the point of entry, with a combination of line-to-line capacitors, capacitors to ground and a common-mode choke, and it is mounted so that its input wiring stays separate from its output wiring and its ground has a short, low-impedance connection.

  • How is an EMC pre-assessment carried out in your own laboratory?

    With basic instruments: near-field probes, a current clamp, a line impedance stabilization network and a spectrum analyzer. It serves to detect problems and compare corrections, but it does not replace the formal test; margin must be left for uncertainty.

  • How is an emission source located with near-field probes?

    A near-field probe connected to a spectrum analyzer is swept over the circuit, and the rise in level at the problem frequency is followed until the point of maximum level is found. That point marks the source or the element radiating it.

  • How is common-mode current measured on a cable?

    A current clamp is placed around the complete cable, with all its conductors inside, and read on a receiver or analyzer. Because differential currents cancel inside the clamp, the reading corresponds to common mode only, converted using the transfer impedance of the clamp.

  • How is conducted disturbance measured on a power network?

    The equipment is connected to the network through a line impedance stabilization network (LISN), which presents a defined impedance and delivers to the receiver the disturbance voltage of each conductor with respect to ground, using the detector and frequency range set by the applicable standard.

  • How is EMC addressed in battery-powered equipment?

    It is addressed as in any other equipment, by identifying sources, coupling paths and victims, with the difference that no mains supply is connected in normal use, while switching converters, a charger and cables acting as antennas are present.

  • How is EMC applied in electric vehicle design?

    In an electric vehicle, electromagnetic compatibility is applied from the design stage because the traction inverter, the charger and the converters switch high currents and coexist with radio, sensors and data networks inside the same vehicle.

  • How is equipment prepared for an emissions test?

    It is prepared by fixing a representative, reproducible configuration: operating modes that produce the highest emission, cables and peripherals arranged as in normal use, software that exercises all functions and complete documentation of what is being tested.

  • How is immunity to radiated fields measured?

    A uniform, modulated electromagnetic field is generated with an antenna and an amplifier and swept in frequency over the equipment, while observing whether its operation stays within the defined performance criterion. The field strength is calibrated beforehand with a probe in the test area.

  • How is radiated emission measured at a test distance?

    The field strength of the equipment is measured with an antenna at a defined distance and a receiver, rotating the equipment and varying the height and polarization of the antenna to record the maximum. The antenna and cable factors are then applied and the result is compared with the limit at that distance.

  • How is solar inverter interference with a radio resolved?

    First identify how the disturbance reaches the radio (through the DC cables, through the AC output or by radiation), then cut that path with filtering, ferrites on the cables, better routing and grounding, as well as by moving the antenna away from the inverter cables.

  • How is the shielding effectiveness of a material measured?

    The signal transmitted through a sample of the material is compared with the signal transmitted without it, in the same setup, and the difference in decibels is the shielding effectiveness. The most widely used methods are the coaxial line with a sample holder and the chamber with a window in which the sample is placed.

  • How is the transfer impedance of a shielded cable measured?

    Transfer impedance relates the voltage induced in the inner circuit of the cable, per unit length, to the current flowing on the shield. It is measured with a triaxial setup and a network analyzer, and a lower value indicates a better shielded cable.

  • Peak, quasi-peak or average detector?

    The peak detector records the maximum value and is the fastest and most conservative; the average detector reflects the mean value of the envelope and is useful for continuous narrowband signals; the quasi-peak detector weights amplitude according to repetition rate. The following always holds: peak is greater than or equal to quasi-peak, and quasi-peak is greater than or equal to average.

  • Pre-compliance testing or certification testing?

    Pre-compliance tests are exploratory, are carried out during development with simpler instruments, and aim to find and correct problems; certification tests are formal, performed at a validated site with calibrated instruments, and produce the report that supports the declaration of conformity.

  • Semi-anechoic chamber or open-area test site?

    A semi-anechoic chamber controls the environment and allows testing at any hour and in any weather, at the cost of installation and absorbers; an open-area test site avoids the limitations of walls but depends on ambient noise and weather. Both are acceptable if validated for the frequency range.

  • Shielding, filtering or separation: which works best for each problem?

    It depends on how the disturbance couples: shielding addresses field coupling into or out of the enclosure, filtering acts on what travels along the cables, and separation reduces coupling between nearby circuits. The choice is based on the path identified, not on the tool at hand.

  • What are common mode and differential mode?

    In differential mode, the disturbance current travels along one conductor and returns along the other, in opposite directions; in common mode, it flows in the same direction along both conductors and returns through ground or the surroundings. Telling them apart determines which filter and which correction will work.

  • What causes crosstalk between traces on a board?

    Crosstalk arises from coupling between nearby traces: a mutual capacitance (electric coupling) and a mutual inductance (magnetic coupling) transfer part of the signal from the aggressor trace to the victim. It grows with edge speed and with parallel length.

  • What causes interference between a variable-frequency drive and communications equipment?

    The drive switches its output with very fast edges; these abrupt voltage changes generate common-mode currents that flow through the motor cable, through ground and through the power wiring. They couple to the communications equipment by conduction, through the field or through a shared ground.

  • What does “electromagnetic disturbance” mean?

    An electromagnetic disturbance is any electromagnetic phenomenon that can degrade the operation of a device, a system or a living being; it is distinct from interference, which is the effect that disturbance produces.

  • What does CISPR 11 regulate for industrial equipment?

    CISPR 11 sets the limits and measurement methods for radio disturbances from industrial, scientific and medical (ISM) radio-frequency equipment, classified into Groups 1 and 2 and Classes A and B. Several types of industrial equipment, such as adjustable-speed drives, are governed by their own product standard.

  • What does CISPR 32 regulate for multimedia equipment?

    CISPR 32 sets the radio disturbance emission requirements for multimedia equipment, that is, information technology equipment and audio and video broadcast and receiving equipment. It covers conducted and radiated emissions, with equipment classes according to the environment of use.

  • What does electromagnetic “susceptibility” mean?

    Electromagnetic susceptibility is the tendency of equipment to degrade in operation when it receives an electromagnetic disturbance; it is the opposite side of immunity, which is the ability to resist it.