Solar energy

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Central inverter or string inverters?

    The difference is one of architecture: a central inverter concentrates the conversion of many modules in one large unit, while string inverters spread the conversion across several smaller units. Each option changes redundancy, maximum power tracking and maintenance.

  • Grid-tied or off-grid system with batteries?

    A grid-tied system delivers energy to and receives energy from the grid and needs no batteries; an off-grid system must supply the load on its own and requires storage. The decision depends on whether a reliable grid is available at the site.

  • Half-cell or full-cell module?

    A half-cell module uses cells cut in half, so that each one carries half the current. This reduces resistive losses and improves behavior under partial shading compared with a full-cell module.

  • How are energy production and its variability measured?

    The energy production of a solar plant is measured with energy meters at the generation and interconnection points, and its variability is analyzed by comparing time series normalized for irradiation, because the solar resource changes with clouds, seasons and years.

  • How does a photovoltaic cell work?

    A photovoltaic cell converts light into electricity through a semiconductor p-n junction: photons generate electron-hole pairs and the junction's internal field separates them, producing a direct current when the circuit is closed.

  • How does a string inverter work?

    A string inverter converts the direct current from one or more module strings into alternating current synchronized with the grid, while seeking the maximum power point of each input and monitoring the grid and the insulation.

  • How is a commissioning verification of a solar array performed?

    A commissioning verification of a solar array confirms, before operation, that the installation matches the design, is safe and delivers what is expected: inspection, electrical tests, inverter startup and performance comparison.

  • How is a grid-tied PV system sized?

    A grid-tied PV system is sized starting from consumption and available area, estimating the energy per installed kilowatt according to the solar resource, and verifying that strings, inverter and protection devices are compatible.

  • How is a module cleaned without damaging it?

    A module is cleaned without damage by using low-hardness or demineralized water, soft tools and times of low irradiance, avoiding abrasives, harsh chemicals, thermal shock and excessive pressure, and following the manufacturer's instructions.

  • How is a site assessed for rooftop panel installation?

    Assessing a roof for panels consists of verifying three things: that the structure can bear the weight and the wind loads, that the solar resource is usable without significant shading, and that the building's electrical installation can accept the system.

  • How is a string sized for the inverter voltage?

    A string is sized for the inverter voltage by choosing a number of modules in series such that the minimum voltage in hot conditions stays within the maximum power point tracking range and the maximum voltage in cold conditions does not exceed the maximum input voltage.

  • How is an underperforming module string located?

    An underperforming module string is located by comparing equivalent strings under the same conditions, starting with monitoring data and continuing with voltage, current and I-V curve measurements, and with visual and thermal inspection.

  • How is battery storage integrated into a solar system?

    Storage is integrated into a solar system on the DC side, with a hybrid inverter, or on the AC side, with a separate battery inverter. The choice defines the coupling, the backup during blackouts and the way the system is sized.

  • How is compliance of a grid interconnection verified?

    It is verified by confirming that the system meets the technical requirements of the grid and the applicable regulations: connection and disconnection protections, quality of the injected power, metering and documentation, through testing and a review of the configuration.

  • How is DC surge protection designed?

    DC surge protection is designed by identifying the paths through which surges enter, installing protection devices suited to the array voltage, minimizing loop areas in the wiring and ensuring equipotential grounding.

  • How is irradiance measured with a pyranometer?

    A pyranometer measures global irradiance by measuring solar radiation on a flat surface; for the reading to be valid, it must be clean, level or aligned with the plane of interest, free of shade and within its calibration period.

  • How is preventive maintenance of a solar array carried out?

    Preventive maintenance of a solar array combines visual inspections, cleaning according to soiling, checks of connections and structures, periodic electrical tests and tracking of monitoring data, under a program defined by the plant.

  • How is shading measured at a site?

    Shading at a site is measured by determining which part of the horizon and nearby objects blocks the sun at each moment of the year, using horizon survey tools or photographic analysis, and is expressed as an irradiation loss.

  • How is soiling loss evaluated?

    Soiling loss is evaluated by comparing the output of a clean module or cell with that of an identical one exposed without cleaning. The ratio between the two, normally of the short-circuit current, gives the fraction of energy lost to dust.

  • How is the cell temperature of a module measured?

    The cell temperature of a module is not measured directly: it is obtained with a sensor attached to the back of the module and then corrected, or it is calculated from the open-circuit voltage and the temperature coefficient.

  • How is the I-V curve measured in the field?

    A curve tracer is connected to the PV module or string and sweeps the load from short circuit to open circuit while irradiance and temperature are measured at the same time, so the results can be compared with reference conditions.

  • How is the insulation resistance of a PV array measured?

    The insulation resistance of a PV array is measured by applying a test voltage between the live conductors and ground, with the array disconnected from the inverter, to detect leakage that indicates damage to cables, modules or connectors.

  • How is water pumped with solar energy?

    In solar pumping, a photovoltaic array powers a controller or drive that runs the pump; water is stored in a tank instead of energy being stored in batteries. The flow rate follows the irradiance: more sun, higher pump speed and more water.

  • Monocrystalline or polycrystalline silicon?

    The difference lies in the structure of the silicon: monocrystalline silicon is formed from a single crystal and polycrystalline silicon from many grains. The former usually offers higher efficiency per unit area; the latter has historically been associated with lower manufacturing cost.

  • Solar tracker or fixed structure?

    A solar tracker moves the modules to keep them facing the sun and captures more energy than a fixed structure, at the price of mechanisms, controls, maintenance and space requirements. The gain depends on the site.

  • What are the standard test conditions of a module?

    Standard test conditions (STC) are the set of reference conditions under which a module's power is declared: an irradiance of 1000 W/m², a cell temperature of 25 °C and an air mass 1.5 solar spectrum.

  • What does “MPPT” mean?

    MPPT stands for maximum power point tracking. It is the function that adjusts the operating point of a photovoltaic array so that it delivers the greatest possible power under the light and temperature conditions of the moment.

  • What does a solar charge controller do?

    A solar charge controller regulates the current flowing from the PV generator to the battery to charge it without overcharging it, and usually also protects against excessive discharge and reversed connections.

  • What does IEC 61724-1 contribute to system monitoring?

    IEC 61724-1 establishes how to instrument and monitor a photovoltaic system: what to measure, with which sensors, how to log the data and how to calculate indicators such as the performance ratio to compare production against what was expected.

  • What does the IEC 60904-1 standard measure for the I-V curve?

    IEC 60904-1 describes how to measure the current-voltage characteristic of a photovoltaic device: it defines the procedure, the irradiance and temperature conditions, and the instrument requirements so that the curve is comparable.