Industrial electrical systems

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Air-Insulated or Gas-Insulated Switchgear?

    Air-insulated switchgear uses air as the insulation between live parts, so it needs more space; gas-insulated switchgear encloses the live parts in sealed compartments with a gas of higher dielectric strength and is much more compact.

  • Direct-On-Line, Wye-Delta or Soft Starter?

    The choice between direct-on-line, wye-delta and soft starter depends on how much starting current and torque the supply and the load can tolerate: direct-on-line is simple but abrupt, wye-delta reduces the current with a torque jump, and the soft starter controls it gradually.

  • Fuse or Circuit Breaker to Protect a Circuit?

    A fuse protects by melting an element that is destroyed when it operates, with a great ability to limit fault current, while a circuit breaker opens a mechanism that can be reset and offers settings and additional functions.

  • How Are Loads Balanced Between Phases in a Panel?

    Load balancing between phases consists of measuring the current in each phase over a representative operating cycle and redistributing single-phase circuits so that the three phases end up as similar as possible.

  • How Do You Prepare an Installation for a Load Expansion?

    To expand the load, you must confirm with measured data that every element in the supply chain has enough capacity: transformer, conductors, busbars, protective devices and short-circuit levels, not just the main breaker.

  • How Does a Circuit Breaker Electronic Trip Unit Work?

    An electronic trip unit measures current with sensors, calculates its RMS value in a microprocessor and commands the breaker to open according to configurable protection curves for overload, short circuit and ground fault.

  • How Does a Medium-Voltage Potential Transformer Work?

    A medium-voltage potential transformer reduces the system voltage to a standardized, safe value, proportional to and in phase with the original, to supply meters, protection and control.

  • How Does a Soft Starter Work?

    A soft starter controls the start of an induction motor by gradually increasing the applied voltage through thyristors, which reduces starting current and torque without changing the frequency.

  • How Is a Battery Backup System Integrated in a Plant?

    Integrating battery backup requires defining which load is backed up and for how long, choosing between a UPS and a DC system, and designing protection, ventilation and maintenance specific to the batteries.

  • How is a single-line diagram of an existing plant surveyed?

    It is surveyed by walking the installation from the service entrance toward the loads, recording each piece of equipment with its nameplate data and physically verifying each connection, rather than relying on old drawings.

  • How is a substation restarted after a long planned outage?

    Restarting a substation after a long planned outage requires first verifying that it is fit to be energized, removing in an orderly way everything placed for the work, and energizing in stages, without load, before loading it gradually.

  • How Is a Transfer Between the Normal Source and an Emergency Generator Planned?

    A transfer between the normal source and an emergency generator is planned by defining which loads to back up, how the changeover will be made without backfeeding the utility, how the generator starts and picks up load, and how the protection is coordinated.

  • How Is an Installation Verified Before It Is Energized for the First Time?

    Before first energization, you verify that the actual installation matches the design, that it is well built, and that de-energized and functional tests confirm it can be energized in stages safely.

  • How is an inverse-time overcurrent relay set?

    An inverse-time overcurrent relay is set by choosing the pickup current, the curve, and the time multiplier so that it operates quickly on heavy faults, ignores normal load, and coordinates with neighboring devices.

  • How is conductor size selected by ampacity and short circuit?

    A conductor's size must meet three conditions at once: its ampacity must handle the load current under the installation conditions, the voltage drop must be acceptable, and it must thermally withstand the short-circuit current until the protection clears it.

  • How is electrical predictive maintenance planned?

    Electrical predictive maintenance is planned by identifying which equipment is critical, how it fails, which measurable variable anticipates each failure, and how often it should be measured in order to act before the failure occurs.

  • How Is Motor Starting Current Measured?

    Motor starting current is measured by recording the current throughout the entire start with an instrument capable of capturing the initial peak and the decay, not with an averaged reading.

  • How Is Motor Winding Resistance Measured?

    The winding resistance of a motor is measured with the motor de-energized and cold, using a four-wire low-resistance instrument, phase to phase, and is corrected for temperature before comparing.

  • How Is Phase Rotation Verified?

    Phase rotation is verified with a phase sequence meter connected to the three phases, which indicates whether the sequence is forward or reverse; the motor's direction of rotation is then confirmed and, if necessary, two phases are swapped with everything de-energized.

  • How Is the Ohmic Contact Resistance of Power Circuit Breakers Measured?

    The ohmic resistance of the contacts of a power circuit breaker is measured with a micro-ohmmeter that injects a high direct current and measures the voltage drop over four wires, with the breaker closed and de-energized.

  • How Is the Remaining Life of an Old Feeder Assessed?

    The remaining life of a feeder is not measured with a single test: it is estimated by combining its load and fault history, the condition of its insulation and accessories, and the trend of the results over time.

  • How Is the Slip of an Induction Motor Measured?

    The slip of an induction motor is measured by comparing its actual speed, measured with a tachometer, with its synchronous speed, which depends on the supply frequency and the number of poles.

  • How Is the Temperature of an Operating Panel Measured?

    The temperature of an operating panel is measured mainly with infrared thermography and is interpreted by comparing similar components and phases with one another, at the actual load at that moment, not from an isolated absolute value.

  • How is voltage drop calculated in a feeder?

    Feeder voltage drop is calculated by multiplying the current by the effective impedance of the conductor, which combines resistance and reactance with the power factor, and it is expressed as a percentage of nominal voltage.

  • Induction Motor or Synchronous Motor in an Industrial Application?

    The induction motor is rugged, simple and self-starting, which is why it dominates industry; the synchronous motor runs at an exact speed, can correct power factor and is useful for large constant-speed loads, at the cost of more complex excitation and starting.

  • Solidly Grounded or Resistance Grounded System?

    The difference lies in how much ground-fault current is allowed: with solid grounding the current is very high and the fault is cleared immediately; with a resistor it is deliberately limited to reduce damage and, in some schemes, to keep operating.

  • What Causes a Fuse to Open Without an Evident Fault?

    A fuse opens without an evident fault because its element has fatigued from repeated heating, has seen a current peak higher than its curve tolerates, has run hot because of a poor connection, or is not the right type for the load.

  • What Does “Ampacity” Mean?

    Ampacity is the maximum current a conductor can carry continuously, under the given installation conditions, without its insulation exceeding its permitted temperature.

  • What Does “Libranza” Mean?

    In the electrical field, a libranza is the formal authorization to work on equipment or a circuit that has been disconnected, isolated, verified de-energized and grounded, under the responsibility of identified persons.

  • What Does a Variable Frequency Drive Do?

    A variable frequency drive controls the speed and torque of an AC motor, generating a voltage of adjustable amplitude and frequency from the supply by means of a rectifier, a DC bus and an inverter.