Dielectric oils

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Flat or spherical electrodes in the oil dielectric strength test

    The difference between flat and spherical electrodes lies in the shape of the electric field: flat electrodes produce a more uniform field and a test less sensitive to contaminants, while spherical or rounded-profile electrodes produce a more divergent field and detect water and particles better.

  • How do you decide when to degas a transformer?

    The decision to degas is made when the oil contains gases or moisture that are no longer justified and the cause of their generation is under control; doing it before understanding the fault erases diagnostic information.

  • How Do You Take an Oil Sample Without Contaminating It?

    A representative oil sample is taken with clean, dry containers, purging the sampling valve beforehand, avoiding contact with air and moisture, and recording the condition of the equipment; any contamination distorts the diagnosis.

  • How does a gas chromatograph for oil work?

    A gas chromatograph separates the components of a gas mixture by passing it with a carrier gas through a column in which each gas advances at a different speed, and quantifies them with detectors at the outlet.

  • How does an online gas monitor work?

    An online gas monitor is installed on the transformer, continuously extracts gases from the oil through a membrane or a chamber, and measures them with sensors or a compact chromatograph to record how they evolve and raise an alert if they increase.

  • How is a transformer’s sampling interval determined?

    A transformer's sampling interval is set according to its importance, load, age, gas history and the trend of the results: the faster the indicators change or the more critical the equipment, the shorter it must be.

  • How Is Aged Oil Regenerated?

    Aged oil is regenerated by passing it through an adsorbent medium, such as Fuller's earth or activated alumina, that retains acids and polar compounds; it is then re-inhibited to restore its protection against oxidation.

  • How is an insulating oil spill handled?

    An insulating oil spill is handled in this order: secure the area, stop the source, contain, recover, clean up, manage the waste, and report according to the applicable environmental regulations.

  • How is an oil result compared with the equipment history?

    An oil result is compared with the equipment history by checking its trend against earlier samples taken under equivalent conditions, because what matters is the rate of change and whether the value is consistent with the load, the temperature and the interventions on the equipment.

  • How Is an Oil Sample Transported and Stored?

    An oil sample is transported and stored in its sealed container, protected from light and extreme temperatures, with no air space when it is for gas analysis, and it is analyzed as soon as possible to prevent its composition from changing.

  • How Is Combustible Gas Content Measured?

    The combustible gas content of oil is measured by extracting the dissolved gases from a sample and separating them by gas chromatography, with detectors that quantify hydrogen, hydrocarbons and carbon oxides against calibrated standards.

  • How Is Dissolved Gas Analysis Interpreted with the Ratio Method?

    The gas ratio method interprets a dissolved gas analysis by comparing proportions between characteristic gases, not their absolute values, to classify the probable fault: partial discharge, low- or high-energy discharges, or thermal fault.

  • How is furan content in oil measured?

    Furans in oil, such as 2-furfural, are measured by extracting them from the oil and analyzing them by liquid chromatography with an ultraviolet detector; their presence reflects thermal degradation of the cellulose in the insulation.

  • How is inhibitor content measured?

    Inhibitor content in oil is normally determined by infrared spectroscopy, measuring the characteristic absorption of the antioxidant's phenolic group, or by chromatographic methods that separate and quantify the additive.

  • How is newly received oil validated?

    New oil is validated by comparing its documentation with what was ordered, inspecting containers and seals, and testing a representative sample against the purchase specifications before filling the equipment.

  • How Is Oil Dehydrated in the Field?

    Oil is dehydrated in the field by circulating it through a unit that heats it moderately and exposes it to vacuum to evaporate the water; however, most of the water is in the paper, so complete drying is slow.

  • How Is Oil Filtered and Degassed Under Vacuum?

    To filter and degas oil under vacuum, the liquid is circulated through filters and a low-pressure chamber where water and dissolved gases come out of solution, while moderate heating aids the process.

  • How is oil viscosity measured?

    The viscosity of an insulating oil is measured with a capillary viscometer: the time a fixed volume takes to flow by gravity through a calibrated tube, in a bath held at a stable temperature, is measured and multiplied by the instrument constant.

  • How is oil with polychlorinated biphenyls handled?

    Oil containing polychlorinated biphenyls (PCBs) is handled as hazardous material: it is identified by analysis, segregated without being mixed, and managed through authorized channels according to the applicable regulations.

  • How is particle content measured?

    Particle content in oil is measured with an automatic counter that passes the oil between a light source and a detector and counts and sorts the particles by size according to the light they block, or it is determined by filtration and microscope counting.

  • How Is the Neutralization Number Measured?

    The neutralization number is measured by titrating a portion of oil, dissolved in a solvent, with a standard alkaline solution until the equivalence point is reached; the result is expressed in milligrams of potassium hydroxide per gram of oil.

  • How is the relative water saturation of an insulating oil calculated?

    The relative water saturation of oil is calculated by dividing the measured water content by the maximum solubility of water in that oil at the sample temperature and expressing the result as a percentage. It thus indicates how close the oil is to saturation.

  • How is the remaining life of paper determined from the oil?

    The remaining life of paper is estimated from the degree of polymerization of the cellulose; using the oil, an indirect estimate is made through furans, carbon oxide gases, moisture, and acidity.

  • How is the resistivity of an insulating oil measured?

    The resistivity of an insulating oil is measured by applying a DC voltage between the electrodes of a cell of known geometry at a controlled temperature, measuring the current after a fixed electrification time, and calculating the resistance using the geometric constant of the cell.

  • How is water distributed between oil and insulating paper?

    Water in a transformer is distributed between the oil and the paper according to a temperature-dependent equilibrium: the paper stores the vast majority and the oil only a fraction, so measuring the oil requires knowing the temperature in order to estimate how much moisture is in the solid insulation.

  • How is water in oil measured with coulometric Karl Fischer?

    In coulometric Karl Fischer, the water in the sample reacts with iodine generated electrolytically inside the cell, and the amount of water is calculated from the electric charge consumed, with no need for a prepared titrant. It is the suitable method for very low contents such as those in insulating oil.

  • Inhibited or uninhibited oil?

    An inhibited oil contains an antioxidant that delays its oxidation and extends its service life, whereas an uninhibited oil oxidizes sooner; the choice depends on the type of transformer and on whether the inhibitor can be monitored and replenished.

  • Manual sampling or online monitoring?

    Manual sampling with laboratory analysis offers a broad, precise profile at intervals, while online monitoring provides continuous tracking of a few parameters; in practice they complement each other rather than exclude each other.

  • Mineral oil or natural ester fluid?

    Mineral oil and natural ester fluid are both valid liquid insulators with different profiles: ester offers a higher flash point and better moisture tolerance, while mineral oil offers more field experience, lower viscosity, and better oxidation stability.

  • Oil reclamation or replacement?

    Reclamation makes sense when the oil is degraded but the equipment and paper are still in acceptable condition, and replacement when contamination or deterioration is such that treating the oil is not enough or is not viable.