24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

RF and microwave

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Coaxial Cable or Waveguide?

    Coax is the practical, broadband option from DC up to very high frequencies; waveguide wins when lower loss or more power is needed at microwave frequencies, at the cost of limited bandwidth, rigidity and size.

  • Fixed or Variable Attenuator in a Measurement Chain?

    Use a fixed attenuator when you need a stable level and good matching; use a variable one when the level must be adjusted during the measurement. The fixed type is more repeatable; the variable type is more flexible and less accurate.

  • How Does a Directional Coupler Work?

    It is a four-port component that takes a known fraction of the signal traveling in one direction and delivers it to a coupled port, while almost none of the signal traveling in the opposite direction reaches that port.

  • How Does a Swept Spectrum Analyzer Work?

    It is a superheterodyne receiver that mixes the signal with a swept local oscillator, filters it with a narrow intermediate-frequency filter and detects it, displaying the level of each frequency as the sweep advances.

  • How is a cavity filter tuned with the analyzer?

    By watching the reflection and transmission on the screen and adjusting the screws of each resonator until its response settles at the center frequency, and the coupling screws until the bandwidth and passband shape are achieved.

  • How Is a Limiter or Input Protector Tested?

    It is verified in two regimes: with a small signal, to confirm that it has almost no effect on the useful signal, and at high power, to measure the level at which it starts limiting, how much power it lets through and how long it takes to recover.

  • How is a network analyzer calibrated with the SOLT method?

    Four known standards (short, open, load and direct connection) are measured so that the analyzer can calculate the systematic errors of the instrument and cables and remove them mathematically from every subsequent measurement.

  • How Is a Power Amplifier Characterized in Its Linear Region?

    Gain, matching and frequency response are measured with low-level signals, and a power sweep that locates the onset of compression determines up to what input level the gain remains constant.

  • How Is a Power Divider Evaluated?

    A network analyzer is used to measure insertion loss, amplitude and phase balance between outputs, isolation between them and the match at each port, always terminating the ports not being measured with loads.

  • How is a test fixture de-embedded?

    The fixture is measured or modeled separately and its effect is removed mathematically from the measurement of the assembly, so that the result corresponds to the device at its own reference plane.

  • How is a time-domain measurement made with a VNA?

    The frequency response is measured and the analyzer converts it to the time domain with an inverse transform; the result shows where each reflection is and how large it is along a line or device.

  • How is a TRL calibration performed and when is it used?

    A direct connection, a reflect and one or more lines of known length are measured; since only the line needs a precise definition, the method is highly accurate in media where good standards do not exist, such as waveguide, microstrip or wafers.

  • How is an RF test bench designed?

    You start from what needs to be measured, define the frequency and power range, choose the chain of sources, filters, attenuators and receivers, and verify with a level diagram that each stage operates in its linear region and within its safe range.

  • How is calibration checked with a verification standard?

    A device whose behavior is known and that was not used in the calibration is measured, and the results are compared with its reference values within the expected uncertainty; if they agree, the calibration is working.

  • How is noise figure measured with the Y-factor method?

    In the Y-factor method, a calibrated noise source is connected to the input of the device, first off and then on, and the increase in noise power at the output is measured; the noise figure is obtained from that ratio and the excess noise of the source.

  • How is the connection repeatability of a coaxial connector evaluated?

    The connection repeatability of a coaxial connector is evaluated by connecting and disconnecting the same connector several times at a controlled torque, measuring the S-parameters each time, and calculating the spread of the results across the band.

  • How is the frequency of an oscillator measured accurately?

    With a frequency counter whose time base is much more accurate than the oscillator being measured, ideally synchronized to a common external reference, and with a gate time sufficient for the desired resolution.

  • How is the group delay of a filter measured?

    The transmission phase is measured across frequency and its negative slope is calculated; group delay indicates how much the signal envelope is delayed at each frequency and reveals the phase distortion of the filter.

  • How is the insertion loss of a connector or adapter measured?

    By measuring the S21 transmission through a calibrated direct connection and then with the component inserted; the difference is the insertion loss, which includes resistive loss and the effect of mismatch.

  • How Is the Integrity of a Long Transmission Line Verified?

    Return loss and insertion loss measurements across the whole band are combined with time-domain fault location, which shows where each reflection occurs along the line.

  • How is the isolation between ports of a divider measured?

    By measuring the transmission between the two output ports with the input terminated in a matched load and the remaining ports loaded; the level of that transmission, in decibels, is the isolation.

  • How is the power of a microwave signal measured?

    With a power meter and a sensor suited to the frequency, level and type of signal, applying the calibration factor for the frequency and taking into account the match between source and sensor.

  • How is the quality factor of a resonator measured?

    The quality factor of a resonator is measured from its frequency response, by dividing the resonant frequency by the half-power bandwidth, and then correcting for the effect of coupling to obtain the resonator's own unloaded quality factor.

  • How is the reflection coefficient of a load measured?

    With a network analyzer calibrated for one port at the load connector, measuring S11; the result is a complex number that can be viewed as magnitude and phase, VSWR, or impedance on the Smith chart.

  • How is the resolution bandwidth selected?

    According to what you want to see: a narrower bandwidth separates nearby signals and lowers the displayed noise floor, but lengthens the sweep; a wider one sweeps quickly but merges signals and raises the noise.

  • Low-Noise Amplifier or Power Amplifier?

    A low-noise amplifier is placed at the start of a receiver to add minimal noise to weak signals; a power amplifier is placed at the end of a transmitter to deliver the required output level with the necessary linearity and efficiency.

  • Mechanical or Electronic Calibration on a VNA?

    Mechanical calibration uses physical standards that are connected one at a time; electronic calibration uses a module with switchable internal states. Electronic calibration is faster and more repeatable, while mechanical calibration allows the best reference when done carefully.

  • Spectrum Analyzer or Network Analyzer: What Does Each One Measure?

    A spectrum analyzer measures which signals are present at its input and their amplitude at each frequency; a network analyzer measures how a device transforms a signal that the analyzer itself generates, with magnitude and phase.

  • Type N, SMA or precision connector: which to choose for your application

    The choice between a type N, SMA or precision connector depends on the maximum frequency, the repeatability required, the power, the size and the number of connections: type N is rugged and general purpose, SMA is compact, and precision connectors are chosen when measurement accuracy matters.

  • What Are a Ferrite Circulator and Isolator?

    They are non-reciprocal three-port devices that use magnetized ferrite to make the signal circulate in only one direction from port to port; an isolator is a circulator with one port terminated in a load, which passes the signal in one direction and absorbs the reverse signal.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer