Chroma 11800 for capacitor ripple current
Chroma 11800 rental for capacitor ripple current
The Chroma 11800 is a digital tester for service life testing of electrolytic capacitors. It supplies a constant ripple current and a controlled peak voltage at a fixed frequency of 1 kHz. It simulates thermal and electrical stress conditions through accelerated aging, to evaluate the durability and long-term degradation of the component. Its four-terminal measurement system minimizes errors due to contact resistance.
DC electronic loads
DC electronic load rental in Monterrey.
We rent the Fluke 435 II power quality analyzer for electrical studies in industrial, commercial and generation facilities. It measures and records voltage, current, power, energy, power factor, harmonics, flicker, unbalance, transients, and voltage sags and swells, and complies with power quality measurements in accordance with IEC 61000-4-30 Class A.
ESD electrostatic charge meter
ESD electrostatic charge meter rental in Monterrey.
We rent instruments for measuring and controlling electrostatic charge in Monterrey, Nuevo León. They evaluate the buildup of static electricity on surfaces, materials, equipment and work areas. They detect and quantify electrostatic charges and fields and identify areas at risk of ESD events that can affect electronic components, sensitive devices and manufacturing processes. They are used to verify electrostatic control in EPA areas, electronics production lines, laboratories and workstations.
High-precision power supply
High-precision power supply rental.
We rent Power Ten high-precision power supplies in Monterrey, Nuevo León, for testing and characterizing electronic equipment, power devices, circuits, modules and industrial systems that require stable, controlled DC power. They offer high stability, low noise and precise voltage and current regulation. They are used for consumption testing, supply variation testing, design validation and fault diagnosis, in engineering laboratories, electronics development, production testing and precision DC work.
Time and frequency counter with rubidium
Time and frequency counter with rubidium rental, Monterrey
We rent the SRS SR620 frequency and time counter for high-precision measurements in electronics, instrumentation and metrology. It measures frequency, period, time interval, phase and pulse width and characterizes signals with high time resolution. It measures frequency up to 1.3 GHz. It is useful in calibration laboratories, electronics development, circuit testing and verification of signal sources.
Charge Plate Analyzer (CPA) for ESD static electricity control
Charge Plate Analyzer (CPA) rental for ESD static electricity control, Monterrey.
The Charge Plate Analyzer (CPA) evaluates the performance of ionizers and ESD control systems in critical manufacturing areas. It measures balance voltage (Offset Voltage) and discharge time (Decay Time), to verify that ionizers neutralize electrostatic charges quickly and evenly. It protects sensitive electronic components, semiconductor devices, medical equipment, lithium batteries and high-technology products against damage from electrostatic discharge (ESD). In accordance with standards such as ANSI/ESD STM3.1 and IEC 61340.
Active probes for oscilloscopes
Active oscilloscope probe rental, Monterrey.
We rent active oscilloscope probes for measuring high-frequency electrical signals with greater accuracy and less loading on the circuit under test. They are used for electronics, signal analysis, circuit diagnostics, signal integrity and laboratory testing.
Digital oscilloscopes and probes
Digital oscilloscope and probe rental in Monterrey.
We rent digital oscilloscopes in Monterrey, Nuevo León, for diagnostics, maintenance, electronics development, laboratory testing and troubleshooting of electrical and electronic systems. We measure waveforms, frequency, amplitude, period, transients, noise and high-speed signals, and analyze the behavior of circuits and devices in real time. Renting is a practical alternative when you need specialized instrumentation for a set period.







