Metrology and calibration: calibration equipment for rent in Monterrey

Calibration equipment for rent for temperature, pressure, current loops, speed and thermal imaging cameras, in the laboratory or in the field.

Metrology and calibration equipment in Monterrey

Calibration equipment for rent

Dry well for calibrating thermocouples and RTD sensors

Dry well rental for calibrating temperature probes

Dry well rental for temperature calibration in Monterrey or anywhere in Mexico. The units have various operating ranges and are used to calibrate thermocouples, Pt100 and Pt1000 RTD sensors, temperature transmitters, digital thermometers and industrial instrumentation. The dry wells offer thermal stability, digital control and inserts for different sensor diameters, in the laboratory and in the field.

Omega S506 hydraulic hand pump for generating pressure

Omega S506 hydraulic hand pump rental

The Omega S506 hydraulic hand pump generates the pressure for calibrating and verifying pressure gauges, pressure transmitters, pressure switches, indicators and process calibrators, in the laboratory or directly in the field. It generates pressures up to 10,000 psi (700 bar) and has a fine adjustment system for reaching the calibration point.

Fluke 789 ProcessMeter, current loop calibrator

Process calibrator rental for 4-20mA current loops

The Fluke 789 ProcessMeter is used to calibrate, verify and troubleshoot industrial process instrumentation. It combines a digital multimeter with a current loop calibrator (Loop Calibrator): it measures and sources 4-20 mA signals, and measures AC/DC voltage, current, resistance, frequency and continuity. It is used in the maintenance of pressure, temperature, level and flow transmitters.

Digital tachometer for measuring RPM

Digital tachometer rental for RPM measurement in Monterrey

Digital tachometers for measuring and verifying the rotational speed of electric motors, industrial machinery, fans, pumps, conveyor belts and other rotating equipment. They measure RPM (revolutions per minute) with optical or contact methods, depending on the model and application. They are also used in functional testing, preventive maintenance, machinery diagnostics, calibration and metrology.

Fluke 750P29 3000 PSI pressure module

Fluke 750P29 3000PSI pressure calibration module rental

The Fluke 750P29 pressure module calibrates and verifies pneumatic and hydraulic pressure instruments up to 3,000 PSI (200 bar). It is compatible with the Fluke 754, Fluke 753, Fluke 725 and Fluke 726 process calibrators and other 750 series equipment. It is used for pressure gauges, pressure transmitters, pressure switches, indicators and hydraulic systems with air or oil. The units are delivered inspected and ready to operate.

Blackbody calibrator for infrared thermal imaging cameras

Blackbody calibrator rental for infrared thermal imaging cameras

Blackbody calibration sources for verifying thermal imaging cameras, pyrometers, non-contact infrared thermometers and radiation temperature sensors. They provide a stable, high-emissivity thermal reference for validating the accuracy of your instruments before inspections, maintenance, audits or calibration processes.

Fluke 754 Documenting Process Calibrator

Fluke 754 process calibrator rental

The Fluke 754 Documenting Process Calibrator is a multifunction calibrator for process instruments. It sources and measures electrical signals such as mA, V, mV, ohms, frequency, pressure and temperature. It works with thermocouples (J, K, T, E, N, R, S, B), RTDs (Pt100, Pt1000) and HART process transmitters. It is widely used in industrial maintenance, calibration laboratories, manufacturing plants and the pharmaceutical, petrochemical, energy and food industries.