Electric vehicles

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Charging at home or at a public station?

    Home charging is slower and cheaper to install and happens while the vehicle is parked; public charging offers higher power and availability away from home, with more variables of access, communication and compatibility.

  • How are the cells in a pack balanced?

    Cells are balanced by equalizing their state of charge: the passive method dissipates energy from the highest cells in resistors, and the active method transfers it between cells.

  • How are vehicle batteries reused in stationary storage?

    Vehicle batteries are reused in stationary storage after assessing their condition, sorting modules of similar performance and reconfiguring them with a new management system, converter and protections, in applications that demand less power.

  • How do you work safely on a vehicle’s high-voltage system?

    Working safely on a vehicle's high-voltage system means that only qualified, trained personnel intervene, following the manufacturer's procedure, with verified de-energization, lockout, suitable protective equipment and insulated tools.

  • How does a battery electric vehicle work?

    A battery electric vehicle stores energy in a battery pack, converts it into three-phase alternating current with a traction inverter and drives the wheels with an electric motor. It has no combustion engine or fuel tank.

  • How does a vehicle insulation monitor work?

    An insulation monitor watches the resistance between the high-voltage poles and the chassis by measuring its leakage with a signal or a voltage bridge, and it issues a warning or opens the contactors when the resistance falls below the threshold.

  • How is a battery cycle life test performed?

    A cycle life test repeatedly charges and discharges a battery under defined conditions and measures how much capacity it retains over the cycles and how its resistance changes, until it reaches a predetermined end-of-life criterion.

  • How is a charging station verified before commissioning?

    Before a charging station is energized, checks confirm that the installation is safe and that the equipment behaves as it should: inspection, ground continuity, insulation, protective devices, and a functional test that simulates the vehicle.

  • How is a fleet charger tested?

    A fleet charger is tested by verifying energy delivery, communication with the actual vehicle models, protections, load management when several vehicles charge at once, and the effect on the site's installation and grid connection.

  • How is an onboard charger diagnosed?

    Diagnosing an onboard charger involves comparing the AC input power with the DC output power, verifying communication with the station, and reviewing fault codes, temperatures and insulation.

  • How is battery capacity estimated with a controlled discharge?

    Capacity is estimated by discharging the fully charged battery at constant current down to its cutoff voltage and integrating the current over time; the result in ampere-hours depends on the test current and temperature.

  • How is cell temperature measured during fast charging?

    Cell temperature during fast charging is measured with thermocouples or NTC sensors attached to the hottest areas, with isolated acquisition and logging synchronized with the current.

  • How is charging integrated with solar generation?

    Charging is integrated with solar generation through a meter at the point of connection that reports the surplus, so that the charger modulates its current to consume the available photovoltaic energy and makes up any shortfall from the grid.

  • How is the distortion a charger generates on the grid measured?

    The distortion a charger injects into the grid is measured with a power quality analyzer at the AC input, logging current harmonics, total distortion and power factor at different power levels throughout the charging session.

  • How is the efficiency of a charger measured?

    The efficiency of a charger is the active output power divided by the active input power, measured at the same time with a power analyzer and at different load levels.

  • How is the electrical installation for chargers sized?

    The installation for chargers is sized from the power and voltage of each charger, treating the load as continuous, with suitable conductors, protective devices and transformer, and considering load management when there are several units.

  • How is the electrical safety of a battery pack tested?

    The electrical safety of a pack is verified with insulation resistance measurements, dielectric strength tests, ground continuity and functional checks of the battery management system's protection functions.

  • How is the insulation between high voltage and chassis measured?

    The insulation between high voltage and chassis is measured with an insulation tester that applies a DC voltage between each pole of the bus and the chassis, or by measuring the system's own voltages, and it is expressed as a resistance.

  • How is the internal resistance of a cell measured?

    The internal resistance of a cell is measured by applying a current step and dividing the change in voltage by the change in current, or with an AC signal of fixed or variable frequency.

  • How is the power consumed by a traction motor measured?

    The power of a traction motor is measured on the electrical side with a power analyzer whose bandwidth is sufficient for the inverter modulation, and on the mechanical side as torque times angular velocity.

  • Lithium-ion or lithium iron phosphate battery?

    Lithium iron phosphate offers greater thermal stability and long cycle life in exchange for lower energy density; metal oxide chemistries with nickel offer more energy per unit mass but require more thermal care.

  • Permanent magnet or induction motor?

    Permanent magnet motors offer higher efficiency and power density, but they depend on rare earth magnets and generate voltage when spinning; induction motors are robust and magnet-free, with lower efficiency at light load.

  • Slow charging or fast charging?

    Slow AC charging is suitable when the vehicle is parked for many hours and a lower installation cost is sought, and fast DC charging when the stop is short, in exchange for higher power and greater thermal demands.

  • Unidirectional or bidirectional charging?

    Unidirectional charging only delivers energy from the grid to the vehicle; bidirectional charging also allows it to be returned, which requires reversible power electronics, grid synchronization, and additional communication and protection.

  • What are the state of charge and state of health of a battery?

    State of charge (SOC) indicates how much charge remains in a battery relative to its current capacity. State of health (SOH) indicates how much it has deteriorated compared with a new battery, normally through loss of capacity or increased internal resistance.

  • What causes an insulation fault on the high-voltage bus?

    An insulation fault on the high-voltage bus is usually due to moisture or condensation, coolant leaks, insulation damaged by abrasion or heat, contamination in connectors, or deterioration of the motor winding.

  • What does “EVSE” mean?

    EVSE stands for Electric Vehicle Supply Equipment: the supply equipment that connects the electric vehicle to the grid and safely controls when and how much energy it receives.

  • What does “vehicle-to-grid” mean?

    “Vehicle-to-grid” refers to the ability of an electric vehicle to return energy from its battery to the electrical grid as well as charge from it, which requires a bidirectional converter, synchronization with the grid and communication with the operator.

  • What does a traction inverter do?

    A traction inverter converts the battery's direct current into alternating current of variable voltage and frequency for a vehicle's electric motor, and in doing so controls its torque and speed.

  • What does ISO 15118 set out on vehicle-to-grid communication?

    ISO 15118 defines the digital communication between the electric vehicle and the charging station, which makes it possible to negotiate charging parameters, authenticate securely, bill automatically and, in recent editions, coordinate bidirectional charging.