How is a point-to-point link aligned?

Direct line of sight with a clear Fresnel zone is ensured, the antennas are roughly pointed using geographic references, and each antenna is then fine-tuned in azimuth and elevation until the received signal is maximized, confirming that it is the main lobe.

Before pointing: the path

A point-to-point microwave link needs line of sight. But the signal does not travel along a thread: it occupies a volume around the line between the antennas, described by the Fresnel zones. If obstacles such as buildings, trees or the terrain intrude on a significant part of the first zone, the signal weakens even if there is direct visibility. That is why the path profile and antenna heights are checked with margin, and the curvature of the Earth is considered on long links.

Coarse pointing

Using coordinates, a map, a compass or visual references, each antenna is oriented toward the other. The polarization, which must be the same at both ends, is set, along with an initial elevation consistent with the difference in heights. The antennas should be secured but with enough play for fine adjustment.

Fine pointing

  1. With the link active, read the received signal level at one end, either on the equipment’s own indicator or with an analyzer.
  2. Move only one antenna and one axis at a time, in small steps, and wait for the reading to stabilize.
  3. Find the maximum in azimuth, then in elevation, and repeat until there is no further improvement.
  4. Go to the other end and repeat, because both ends refine the result.
  5. Tighten the mounting carefully, checking that the reading does not change as it is secured.

The risk of a side lobe

Antennas have side lobes, and it is possible to point at one of them by mistake, with a reasonable signal that is nevertheless lower than with the main lobe. To avoid this, sweep a wide angular range around the maximum and check that the peak found is the highest and that the signal falls symmetrically on both sides, with the nulls and smaller lobes characteristic of the pattern. If there is a larger peak in another direction, the first one was a side lobe.

What is observed

  • A signal that fluctuates with the wind suggests insufficiently rigid supports or a narrow beam with little margin.
  • A strong signal with errors may indicate interference or cross-polarization, not poor pointing.
  • A maximum that does not coincide with the expected line of sight may be due to reflections; it is advisable to review the path.

Safety

Installation on towers, rooftops and masts involves the risk of falls, electrical hazards and radio frequency exposure. It must be carried out by qualified personnel, with protective equipment and following the applicable regulations. Transmitters must be switched off or at reduced power while anyone is in front of the beam.