24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Thermography

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • How does a cooled-core thermal camera work?

    A cooled-core camera uses a photon detector chilled to a very low temperature to eliminate its own thermal noise, which gives it high sensitivity and very short exposures.

  • How does a thermal camera form an image?

    Using an infrared-transparent lens, the camera focuses thermal radiation from the scene onto a detector array; each element converts that power into a signal that is calibrated to temperature.

  • How is a camera focused for correct measurement?

    Focus on the object to be measured until its edges look sharp, because poor focus mixes radiation from the background with radiation from the object and makes the measured temperature wrong.

  • How is a thermographic inspection documented?

    A thermographic inspection is documented by recording equipment identification, load and ambient conditions, camera parameters, thermal and visible images, analysis, severity and recommendation.

  • How is a thermographic inspection of electrical panels prepared?

    A thermographic inspection of panels is prepared by defining the scope, reviewing load and access conditions, setting up the camera and coordinating with qualified personnel the opening of panels or the use of inspection windows.

  • How is a thermographic inspection of motors performed?

    A thermographic inspection of motors is done with the motor at steady state and under load, checking bearings, frame, terminal box and coupling, and comparing with identical machines or with previous shots.

  • How is active thermography performed?

    Active thermography applies an external thermal stimulus to the object and observes how its surface responds; internal defects alter the heat flow and show up as areas with different behavior.

  • How is load estimated during an inspection?

    Load during an inspection is estimated by measuring the current flowing at the time of the shot or by reading the panel instruments, and comparing it with the rated current of the circuit.

  • How is temperature difference measured against a similar reference?

    Measure the temperature of the suspect component and of an identical one under the same load and conditions, then compare the difference; this removes the effect of the ambient and of the common load.

  • How is temperature measured through an infrared window?

    To measure through an infrared window, use an infrared-transparent material, tell the camera the window transmittance, and pay attention to its cleanliness, angle and temperature.

  • How is the effect of distance compensated for?

    Distance has two effects: the object occupies fewer pixels and is averaged with the background, and the air attenuates the signal. It is compensated by moving closer, using a longer focal length and entering the real distance.

  • How is the emissivity of a surface determined in the field?

    Emissivity is determined in the field by comparing the camera reading with a known temperature of the same surface, or by applying a material of known emissivity and adjusting until the readings match.

  • How is the severity of a thermal anomaly classified?

    The severity of a thermal anomaly is classified by combining the temperature difference from a reference, the load at the time of measurement, the type of component and the consequences of its failure.

  • How is the temperature of a shiny metal object measured?

    A shiny metal has low emissivity and reflects its surroundings, so it is measured by artificially increasing its emissivity with tape or matte paint, or the result is interpreted only qualitatively.

  • How is the temperature of an overhead line measured from the ground?

    From the ground, an overhead line is measured with a telephoto-equipped camera, concentrating on connections and splices, and taking into account distance, wind, sun, conductor emissivity and viewing angle.

  • How is thermography used in a photovoltaic system?

    It is used to locate modules, cells, connections, and boxes with abnormal heating under good irradiance, comparing similar elements and distinguishing real heat from reflections of the sky and the sun.

  • How is thermography used in building and envelope inspection?

    It is used to see surface temperature differences on walls, roofs, and windows that reveal missing insulation, thermal bridges, air leaks, or moisture, always with a temperature difference between indoors and outdoors.

  • How is thermography used in electronics and circuit boards?

    It is used to see how heat is distributed on a running board, locate components dissipating too much or short circuits, and validate the thermal design, using close-focus optics because the targets are very small.

  • How is thermography used in refractory inspection?

    The temperature of the outer metal shell of furnaces, ladles, and ducts is measured; an area of the shell hotter than its surroundings indicates that the inner refractory lining is providing less insulation, due to wear, cracks, or loss of material.

  • How is thermography used on transmission lines?

    It is used to detect splices, clamps, connectors, insulators, and hardware with abnormal heating, viewing them from a distance from the ground, a vehicle, or an aircraft, and correcting for the effects of distance and surroundings.

  • Infrared thermometer or thermal imaging camera?

    An infrared thermometer gives a single value averaged over an area, while a camera gives an image with one measurement per pixel; that is why the camera finds anomalies and the thermometer only confirms temperatures at points already identified.

  • Inspection with open covers or through windows?

    Opening the covers gives the most direct image but exposes personnel to energized equipment; infrared windows allow inspection with the cover closed, at the cost of part of the radiation being attenuated and having to be compensated for.

  • Long-wave or mid-wave camera?

    Long-wave cameras are usually the general-purpose option for electrical and mechanical inspection because of their lower sensitivity to solar reflections and their cost, while mid-wave cameras are reserved for higher-temperature applications, high sensitivity, or gas imaging.

  • Qualitative or quantitative thermography?

    Qualitative thermography looks for patterns and differences between components without assigning a reliable absolute value, while quantitative thermography measures temperatures with controlled emissivity and conditions so they can be compared with criteria or limits.

  • Thermography or ultrasound to detect loose connections?

    They complement each other: thermography detects the heating produced by a high-resistance connection under load, and ultrasound detects the noise of discharges or arcs, so each technique sees a different phenomenon.

  • What are interchangeable lenses in thermography?

    They are optics of different focal lengths mounted on the same thermal imaging camera to change the field of view and the minimum object size that can be measured accurately.

  • What are thermal level and range?

    They are the two settings that determine which temperature interval is spread across the colors of the image: the range or span is the width of the interval, and the level is the central point around which it is placed.

  • What does ASTM E1933 say about emissivity?

    ASTM E1933 brings together test methods for measuring the emissivity of a surface with a radiometric camera and for compensating for it, so that the displayed temperature comes close to the true temperature.

  • What does ISO 18434-1 establish on thermography?

    ISO 18434-1 is a standard in the series on condition monitoring and diagnostics of machines that establishes general procedures for applying infrared thermography as a diagnostic technique.

  • What does ISO 18436-7 cover on personnel certification?

    ISO 18436-7 sets requirements for the qualification and assessment of personnel performing thermography in condition monitoring and diagnostics of machines, and for the bodies that certify them.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer