Confined spaces

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Airline respirator or self-contained breathing apparatus?

    An airline respirator offers practically unlimited duration and lower weight, but it ties the person to a hose and a source; self-contained apparatus offers freedom of movement, but with limited air and a heavier load. The choice depends on distance, duration and hazard.

  • Catalytic or infrared sensor for combustible gases?

    A catalytic sensor detects combustibles by burning them on a hot element and needs oxygen; an infrared sensor measures light absorption by hydrocarbons, does not depend on oxygen and is not poisoned, but it does not detect hydrogen. Each suits different gases and conditions.

  • Forced or natural ventilation in a confined space?

    Natural ventilation depends on wind and temperature differences, which cannot be controlled or guaranteed; forced ventilation uses fans and does allow the flow to be directed and assured, which makes it the reliable option when people or contaminants are inside.

  • How are temperature and humidity measured for heat stress inside the space?

    Temperature and humidity for heat stress inside a space are measured at the work site with an index that combines temperature, humidity, radiation and air movement, such as WBGT, together with the workload and the worker's clothing.

  • How do you enter a sewer or manhole?

    A sewer or manhole is entered only after treating it as a confined space: open and ventilate it, measure the atmosphere, control the flow and traffic, and enter with a permit, harness, attendant and rescue plan.

  • How do you enter a transformer tank for internal inspection?

    To enter a transformer tank, treat it as a confined space: de-energize and isolate it, confirm that the air is breathable, ventilate, measure the oxygen and have an attendant, a permit and rescue in place.

  • How do you inspect a silo or hopper?

    Inspecting a silo or hopper involves its own risks: engulfment by material, a deficient or explosive atmosphere, combustible dust, and material that sticks and then falls. That is why it is emptied, isolated and locked out, and entered only with a permit and a harness.

  • How do you work in a tank with an inert atmosphere?

    In a tank with an inert atmosphere there is not enough oxygen to breathe, so entry is made only with independent supplied air, under a special permit, with an attendant and rescue prepared, and without relying on ordinary oxygen detectors for breathing.

  • How do you work in an underground cable vault?

    Working in an underground cable vault requires treating it both as a confined space and as an electrical installation: check the atmosphere, control water and access, and make sure that the circuits are de-energized or that the work is done by qualified personnel.

  • How does a catalytic combustible gas sensor work?

    A catalytic combustible gas sensor contains two hot elements in a Wheatstone bridge: the gas burns on the active element, whose temperature rises and resistance changes, and that difference from the reference element is the signal proportional to the concentration.

  • How does a four-sensor multi-gas detector work?

    A four-sensor multi-gas detector simultaneously measures oxygen, combustible gases, carbon monoxide and hydrogen sulfide, each with its own sensor, and goes into alarm when any of them moves outside the configured limits.

  • How does an electrochemical gas sensor work?

    An electrochemical gas sensor works like a small cell: the gas passes through a membrane, reacts at a working electrode and the current generated is proportional to its concentration.

  • How is a confined space isolated from energy sources and fluids?

    A confined space is isolated by physically disconnecting it from every energy source and fluid that could activate or enter it, with lockout/tagout of energy and blind flanges or disconnection of piping, and by verifying that the isolation works.

  • How is a confined space ventilated?

    A confined space is ventilated by bringing in clean air and exhausting contaminated air so that the entire volume is renewed, placing the intake away from contamination sources, directing the flow to where people are and measuring to confirm the result.

  • How is a gas detector’s reading tested before use?

    A gas detector is tested before each use with a functional test: it is briefly exposed to a reference gas to confirm that the sensors respond and the alarms activate, which is different from calibration, which adjusts the reading.

  • How is a sample taken at different levels of the space?

    A sample is taken at different levels by lowering a probe with a hose, or moving the detector, to the top, middle and bottom of the space, waiting at each point for the reading to stabilize, because gases stratify according to their density.

  • How is a tank cleaned and gas-freed before entry?

    To clean and gas-free a tank before entry, it is emptied and isolated, residues are removed, vapors are displaced with ventilation, steam, water or inert gas depending on the product, and measurements confirm that the atmosphere is acceptable, bearing in mind that residues may keep emitting.

  • How is an entry permit prepared?

    An entry permit is prepared before going in: the space and the task are identified, hazards are assessed and controlled, conditions are measured, roles and rescue are assigned, and a responsible person authorizes the work in writing for a defined period.

  • How is an entry rescue plan organized?

    An entry rescue plan is organized before anyone goes in: who rescues and how are defined, retrieval systems are set up outside, rescuers are equipped, communication is secured and the plan is rehearsed, with no reliance on improvisation.

  • How is carbon monoxide measured in a workspace?

    Carbon monoxide is measured with a specific electrochemical sensor, in the breathing zone and near combustion sources, and is interpreted by concentration and exposure time, because it is colorless, odorless and binds to hemoglobin, preventing oxygen transport.

  • How is continuous monitoring carried out during the work?

    Continuous monitoring during the work is carried out by keeping a switched-on, verified multi-gas detector in each entrant's breathing zone, with alarms active, readings recorded and one clear rule: on an alarm, get out first and investigate afterward.

  • How is oxygen measured in a confined space?

    Oxygen in a confined space is measured with the oxygen sensor of a calibrated detector, from outside before entry and then at several levels, letting the reading stabilize and keeping measurement continuous during the work.

  • How is the atmosphere assessed before entry?

    It is assessed with a calibrated gas detector, testing the atmosphere from outside at different levels of the space, measuring oxygen first, then flammable gases and then toxic gases, and monitoring continues for as long as anyone is inside.

  • How is the presence of combustible gases measured?

    Combustible gases are measured with a catalytic, infrared or thermal conductivity sensor that reports the result as a percentage of the lower explosive limit, calibrated for a reference gas and sampled at several levels of the space.

  • In-house rescue or external rescue?

    In-house rescue is carried out by the facility's own personnel, who are immediately available and know the space; external rescue is carried out by an outside service, with more experience but with a travel time. The decision depends on whether that time is compatible with the hazard in the space.

  • Personal detector or area detector?

    A personal detector protects the wearer by measuring the air they breathe; an area detector monitors the space in general from a fixed point. They complement each other: the area detector gives early warning, and the personal detector governs the decision to leave.

  • What complements NOM-009-STPS for work at height?

    NOM-009-STPS sets the safety conditions for work at height in Mexico; it is complemented by requirements for personal protective equipment, the selection of fall arrest systems, and rescue and supervision procedures.

  • What does “IDLH” mean?

    IDLH stands for “Immediately Dangerous to Life or Health”: a condition in which an exposure can cause death or irreversible effects, or prevent escape.

  • What does NOM-033-STPS establish?

    NOM-033-STPS is the Mexican standard that sets safety conditions for work in confined spaces: it calls for identifying them, assessing their hazards, authorizing entry, measuring the atmosphere, training personnel and having rescue in place.

  • What does OSHA 1910.146 require?

    OSHA 1910.146 regulates entry into permit-required confined spaces in general industry in the United States: it requires employers to identify them, control their hazards and organize entry with roles, a permit and rescue.