24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

How is a luminaire tested for severe weather conditions?

A luminaire is tested for severe weather by combining temperature and humidity, water and dust ingress, corrosion, radiation and vibration tests, and verifying that it maintains its optical, thermal and electrical function.

What a luminaire must withstand

An outdoor luminaire combines optics, electronics, heat dissipation and an enclosure, and all four suffer in the weather. The aim of the tests is to verify that, after exposure, it remains safe, maintains its performance and does not undergo accelerated degradation.

Main tests

  • Water and dust ingress: the declared degree of protection is verified, with rain, jet or immersion tests as applicable, and dust tests.
  • Temperature and humidity: cycling between extremes, with the luminaire on and off. Condensation inside the optics is a typical problem.
  • Radiation and aging: exposure to simulated ultraviolet light to evaluate yellowing and embrittlement of lenses, diffusers, gaskets and coatings.
  • Corrosion: salt spray, especially for coastal or industrial areas.
  • Vibration and shock: from wind, pole mounting or transport, plus impact resistance of the cover.

What is monitored

The temperature of the driver and the light source, because the life of the electronic components and the light output depend on it. Electrical function, surge protection where applicable and the stability of the luminous flux are verified. Degradation of the optics alters the light distribution, so photometric performance is measured before and after.

Characteristic failures

Water condensed in the enclosure, which corrodes the electronics. Polycarbonate yellowing that reduces transmission. Hardened gaskets that stop sealing after thermal cycles. And overheating if the heat sink gets dirty or the material deforms.

How to interpret the result

The result is compared against the criterion set by the product standard or the customer: no loss of function, no water ingress and photometric degradation within the permitted limit. The tests are accelerations and do not replace field experience, so it is advisable to follow up on installed units.

Notice

Luminaires and their supply circuits operate at mains voltage: tests with the equipment energized, and the installation, must be carried out by qualified personnel following the applicable electrical safety regulations.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer