Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- Why Does a Wireless Sensor Connection Fail in a Plant?
A wireless sensor in a plant usually fails for lack of link margin: metal blocks and reflects the signal, electrical noise and other radios raise the noise floor, and the battery or antenna limit the rest.
- Why does acetylene appear in oil?
Acetylene appears when oil is exposed to very high temperatures, typical of an electric arc or a high-energy discharge, or when a tap changer transfers it to the main tank.
- Why Does an Antenna Exposed to the Weather Degrade?
An antenna exposed to the weather degrades mainly through corrosion of connectors and contacts, moisture ingress into the line and the radome, and aging of materials from ultraviolet radiation and temperature cycling.
- Why Does an Antenna’s Resonant Frequency Change When It Is Installed?
The resonant frequency changes when an antenna is installed because nearby objects, the mast, the mounting surface and the cable alter its near fields and effective capacitance; the antenna measured in open air is not the same as the installed antenna.
- Why does an electrolytic capacitor fail?
An electrolytic capacitor fails mainly through aging of the electrolyte, accelerated by temperature, ripple current and overvoltage, which raises its ESR and reduces its capacitance.
- Why does an electromechanical relay fail?
An electromechanical relay fails because its contacts degrade through electric arcing, because its coil is damaged or loses operating voltage, or because the mechanism wears out. The load and the number of operations determine which appears first.
- Why does an emissions test fail only at certain frequencies?
An emissions test fails only at certain frequencies because emissions are usually narrowband signals, such as clocks, power supply switching and their harmonics, amplified by resonances of cables, apertures or structures that act as efficient antennas at those frequencies.
- Why does an enclosure with an IP seal fail the water test?
An enclosure with a seal fails the water test because the seal is not properly compressed, is damaged or has aged, or because water gets in by another route, such as cable entries, screws or internal pressure changes.
- Why does an induced-voltage shock occur?
An induced-voltage shock occurs because a de-energized conductor that is close to energized lines or equipment, or exposed to a varying field or a lightning strike, acquires voltage through electric or magnetic coupling.
- Why does an installation with good grounding still have noise?
Because a low resistance at the grid frequency does not guarantee low impedance at high frequencies, nor does it prevent ground loops, common-mode currents or badly made shield connections.
- Why Does an Insulating Material Crack from Temperature?
An insulator cracks from temperature when the internal stresses produced by differential expansion, uneven cooling or thermal degradation exceed the strength of the material, especially if it is brittle or already has defects.
- Why does an insulator lose properties with moisture?
An insulator loses properties with moisture because water, which is polar and carries dissolved ions, penetrates the material or adsorbs on its surface, increasing conductivity, permittivity and losses and reducing surface resistance.
- Why does an inverter disconnect on grid voltage?
An inverter disconnects on grid voltage when the voltage at its terminals rises above or falls below the protection limits. With solar generation, the most common case is overvoltage caused by the voltage drop of the injected current itself on a weak grid.
- Why Does Cable Termination Insulation Fail?
Cable termination insulation fails because the termination is the point where the shield is cut and the electric field concentrates, so assembly defects, moisture or contamination can initiate discharges and leakage.
- Why does communication with personnel inside the space fail?
Communication with personnel inside a confined space fails because the enclosure blocks or reflects the signal, noise and protective equipment make speech difficult, and a backup means is not always defined.
- Why does corrosion appear on connectors after salt spray?
Corrosion appears on connectors because the conductive salt film and moisture attack the contact and plating metals, especially where there are galvanic couples, pores or worn plating.
- Why does electronic equipment reset during brief voltage sags?
Electronic equipment resets during brief voltage sags because its power supply can hold the DC voltage only as long as the energy stored in its capacitors lasts. If the sag lasts longer, the voltage falls below the minimum and the equipment resets or trips.
- Why does equipment fail emissions even when its design is correct?
Because the schematic does not include what determines the emission: current return paths, parasitic inductances, loop area, connected cables and the mechanical assembly. An electrically correct circuit can be a good antenna if its physical construction allows it.
- Why does gas accumulate in low areas?
Gas accumulates in low areas when it is denser than air, because gravity settles it and poor ventilation prevents it from mixing; it also stratifies because of temperature and the shape of the space.
- Why does ground resistance change with the seasons?
Ground resistance changes with the seasons because it depends on soil resistivity, which in turn varies with moisture, temperature and dissolved salts, especially in the surface layers the electrode passes through.
- Why does ground resistance vary with the seasons?
Ground resistance varies with the seasons because soil moisture and temperature change, and these govern its resistivity: it rises in dry spells or frost and falls in the rainy season.
- Why does hydrogen increase in oil?
Dissolved hydrogen in oil increases because it is the first gas produced by almost all degradation mechanisms: partial discharges, localized heating and, sometimes, chemical reactions unrelated to a fault.
- Why Does Incorrect Connector Torque Make a Measurement Fail?
Because torque defines how well the contact surfaces join. Too little tightening leaves an irregular, reflective contact; too much deforms the connector and shifts the reference plane. In both cases the measurement stops being repeatable.
- Why Does Insulation Fail from Prolonged Overheating?
Prolonged overheating chemically degrades the insulation, which becomes brittle and loses dielectric strength and mechanical strength, until vibration, an overvoltage or moisture causes the failure.
- Why does mains hum appear on the trace?
Mains hum appears on the trace because the probe, its ground lead or the circuit itself picks up the installation's field at the line frequency, or because a ground loop drives mains current through the measurement connections.
- Why does oil become contaminated with fibers?
Fibers reach the oil from the cellulose insulation itself, from mechanical wear, and from the handling of the oil or filters; with moisture they form bridges that reduce dielectric strength.
- Why does oil form bubbles under load?
Oil forms bubbles under load because heating releases dissolved gas or water vapor from the paper; these bubbles reduce dielectric strength and can initiate discharges.
- Why Does Permittivity Change with Aging?
Permittivity changes with aging because the material changes chemically and physically: it absorbs water, oxidizes, loses additives, degrades or continues to cure, and each of these processes alters polarization and losses.
- Why Does Rain Degrade a Link?
Rain degrades a link because the drops absorb and scatter the energy of the wave, and the effect grows with frequency and with the distance the signal travels through the rain.
- Why does remote communication with an instrument fail?
Remote communication with an instrument usually fails because of settings that do not match at both ends, such as address, speed, terminators or protocol, because of cable problems, or because of malformed or badly timed commands.