Why Does an Antenna Exposed to the Weather Degrade?

An antenna exposed to the weather degrades mainly through corrosion of connectors and contacts, moisture ingress into the line and the radome, and aging of materials from ultraviolet radiation and temperature cycling.

The agents of degradation

An antenna installed outdoors is continuously subjected to water, salts, contaminants, solar radiation, wind and temperature variations. None of these factors usually causes a sudden failure; they almost always produce gradual deterioration that is first noticed as a loss of performance.

Main mechanisms

  • Water ingress: water entering through a poorly sealed connector or through the cable advances along the inside of the coax. It changes the dielectric constant, increases losses and modifies the impedance of the line.
  • Corrosion: contacts between dissimilar metals in the presence of moisture and salts form galvanic couples. Oxide raises contact resistance and can generate passive intermodulation products if there is high power with several carriers.
  • Ultraviolet radiation: degrades plastics, cable jackets and radomes, which become brittle or change in color and dielectric properties.
  • Temperature cycling: repeated expansion loosens joints, cracks seals and fatigues solder joints.
  • Wind and vibration: loosen hardware and misalign the antenna, with a resulting change in pointing.

What the engineer sees in the measurement

With a cable and antenna analyzer, degradation appears as worsening return loss, a shift in the resonant frequency, higher cable attenuation or a localized reflection in the distance domain, which points to a connector or a damaged section. Over time, comparing against the initial installation measurement makes it possible to separate gradual deterioration from an installation defect.

How to reduce the problem

  1. Seal connectors with materials suitable for outdoor use and keep water dripping away, by forming a drip loop before the entry to the equipment.
  2. Choose compatible materials to reduce galvanic corrosion.
  3. Periodically inspect radomes, hardware and seals.
  4. Record a reference measurement at installation in order to detect drift.

Inspections on towers and rooftops and near transmitters must be done by qualified people, following the applicable regulations for work at height and radio-frequency exposure.