The underlying cause
The resonance of an antenna depends on its geometry and on the materials within its near field. Any object in that region changes the current distribution and stores energy differently. The result is a shift in the frequency at which the reactance goes to zero, and a change in the input resistance. The antenna in the lab and the installed antenna are, in practice, different systems.
Typical effects
- Nearby dielectrics: plastic, glass, snow, water or a product housing increase the effective capacitance and usually lower the resonant frequency, because the wavelength inside the material is shorter.
- Nearby conductors: masts, metal walls or plates change the impedance, and the distance to the conductor influences the direction of the shift.
- Finite ground plane: on a monopole, the size and shape of the actual plane differ from the ideal.
- Feed cable: without a balun or a choke, the cable shield becomes part of the antenna and shifts the resonance.
- Hand or body: in portable devices, the user noticeably detunes the antenna.
How it is diagnosed
- Measure the return loss and impedance of the antenna on site, with the analyzer calibrated at the connector.
- Compare them with the free-space measurement or with the data sheet.
- Move or remove suspect objects and observe whether the curve changes.
- Vary the position of the test cable to check for currents on the shield.
What to do with the result
If the shift is small compared with the antenna’s bandwidth, it may be tolerable. If not, the element length is readjusted, the mounting is modified, the distance to the object is increased or a matching network is added. In product design, tuning must be done with the antenna inside its housing and in the position of use, not on an open bench.
A useful clue
If the reflection curve moves when a hand is brought close or the test cable is shifted, the measurement setup is taking part in the antenna’s response.