Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- Why does a gas sensor get poisoned?
A gas sensor is poisoned when certain substances in the air react with its sensing element or coat it and reduce its response; this is chemical damage, it is usually irreversible, and it can happen with no warning on the display.
- Why does a ground conductor heat up during a fault?
Because the fault current dissipates energy in the conductor's resistance; the heating depends on the square of the current and on the time the protection takes to open, set against the conductor's cross-section and material.
- Why does a hot spot not show up in a low-load inspection?
Because the heating of a defective connection grows with the square of the current; at low load, the power dissipated is so low that the temperature difference stays below what can be distinguished from the surroundings.
- Why Does a Laminate Fail by Delamination?
A laminate fails by delamination when the bond between layers breaks under stresses that exceed the interlaminar strength, which is usually much lower than the in-plane strength of the fibers, and the problem is aggravated by moisture, impacts, heat and manufacturing defects.
- Why does a lockout padlock fail in practice?
In practice a lockout padlock almost always fails because of the procedure, not the padlock: it is placed at the wrong point, verification is skipped, someone else removes it, or energy arrives from a source nobody identified.
- Why does a loose connection heat up?
Because a loose connection has less real contact area and higher electrical resistance, and the current flowing through it dissipates power there in proportion to that resistance and to the square of the current.
- Why Does a Material Have High Losses at High Frequencies?
A material has high losses at high frequencies because, as frequency rises, dipoles and charges no longer follow the field in phase, and this delayed response dissipates energy as heat; moisture, impurities and polar groups also play a part.
- Why does a measurement standard deteriorate?
A standard deteriorates through wear, contamination, corrosion, component aging, impacts, improper handling, and storage or use conditions outside those intended, all of which shift its value from the one on the certificate.
- Why does a microcontroller reset when a nearby relay is activated?
Because when the relay coil or contacts open, a transient appears that couples to the microcontroller through the power supply, through the shared ground or through the field, and causes a voltage drop or a pulse on a sensitive line that triggers the reset.
- Why Does a Mismatched Antenna Damage a Transmitter?
A mismatched antenna reflects part of the power back toward the transmitter, and that reflected power adds to the voltage and current in the output stage, which overheats or is subjected to voltages it was not designed to withstand.
- Why Does a Motor Burn Out from Loss of a Phase?
When a phase is lost, the three-phase motor keeps turning as if it were single-phase: the current in the remaining phases increases and the negative-sequence component rapidly heats the rotor and windings until the insulation is damaged.
- Why does a multimeter give unstable readings?
A multimeter gives unstable readings almost always because the signal really is varying, because it is picking up noise or interference on a high-impedance input, or because the contact, range or integration time is not right.
- Why does a multimeter’s internal fuse blow?
A multimeter's fuse blows when more current flows through the current range than it can withstand, almost always because current was measured with the probes in the current terminals connected in parallel across a voltage source.
- Why Does a Porcelain Insulator Become Contaminated?
A porcelain insulator becomes contaminated because wind deposits dust, salt and industrial residues on its surface, and light moisture turns them into a conductive layer that causes leakage and flashover.
- Why does a power resistor burn out?
A power resistor burns out when the power it dissipates exceeds what it can release to the environment, whether because of electrical overload, poor heat dissipation or an unforeseen operating condition.
- Why does a power supply oscillate with certain loads?
A regulated power supply oscillates when the load and wiring modify its feedback loop and erode its phase margin, which is typical with large capacitive loads, long inductive cables or negative-resistance loads.
- Why does a power transistor fail?
A power transistor fails from excessive junction temperature, overvoltage, overcurrent, avalanche or faulty switching, and the cause almost always lies in the surrounding circuit rather than in the device itself.
- Why does a probe ground loop distort a fast signal?
The probe ground loop adds an inductance in series with the input capacitance; together they form a resonant circuit that distorts fast edges with overshoot and ringing that do not belong to the circuit being measured.
- Why does a product fail a humidity test?
A product fails a humidity test because water, whether absorbed or condensed, reduces insulation resistance, opens leakage paths and accelerates corrosion and electrochemical migration.
- Why does a product fail from vibration at resonance?
At resonance, a structure amplifies the input vibration because the excitation frequency matches a natural frequency and damping is low, which raises stresses and accelerates fatigue.
- Why does a residual current device not protect against all contact?
A residual current device detects current that leaks to ground, not just any contact: it does not protect if the current returns through the neutral, if contact is between two live conductors, or against leakage below its threshold.
- Why does a shield with apertures lose effectiveness?
Because an aperture lets the field through and, at some frequencies, behaves like a slot antenna. What counts is the largest dimension of the aperture relative to the wavelength, not its area: a long, narrow slot leaks more than several small holes of the same total area.
- Why does a solar array produce less than expected?
A solar array produces less than expected when one of the actual losses exceeds what was forecast, or when the actual solar resource was lower than assumed. To find out which, compare the measured energy with a model fed with the recorded irradiance and temperature.
- Why does a solder joint detach from a circuit board?
A solder joint detaches when repeated mechanical or thermal stress exceeds what the joint can withstand, or when the joint was weak from the start because of poor metallurgical formation. The cause is almost always fatigue or a process defect, and rarely a sudden failure.
- Why does a transformer hum louder than normal?
Normal hum comes from magnetostriction in the core; if it increases or changes tone, it points to overexcitation, harmonics, loose components or resonances, and must be investigated.
- Why does a variable frequency drive fail when the DC bus voltage drops?
A drive fails during a voltage drop because its inverter is fed from the DC bus, and when that bus falls below its minimum threshold the drive protects itself and trips on undervoltage.
- Why does a vehicle’s range drop in the cold?
Range drops in the cold because the battery delivers less usable energy at a higher internal resistance, and because the vehicle spends more energy on cabin heating, on warming the battery and on overcoming denser air.
- Why Does a VSWR Measurement Change When the Cable Moves?
Because the cable is part of the measurement chain: flexing it changes its phase, its loss and the quality of its connectors, and a calibration made with the cable in another position no longer corrects those changes.
- Why does a waveform show oscillations that do not exist?
A waveform shows nonexistent oscillations because of aliasing, interpolation across too few samples, resonance of the probe itself and its ground connection, or interference entering the measurement.
- Why does a wireless link drop at specific times?
A link that always drops at the same time usually has a cause that is also periodic: interference on a schedule, propagation changes during the day, or machine activity that alters the environment.