What you see in the spectrum
The measured spectrum is normally a low floor with peaks. Each peak has a specific origin: a digital clock and its harmonics, the switching frequency of a power supply and its multiples, or a communications signal. Since emission limits are a line, the peaks that exceed it are the ones that cause the failure.
Why only some frequencies
- Spectral content: periodic digital signals concentrate their energy in the fundamental and its multiples.
- Cable resonances: a cable connected to the equipment behaves like an antenna. Its radiation efficiency is highest at frequencies where its length is related to the wavelength, and the peak appears at those frequencies.
- Structural resonances: slots, apertures, enclosures and ground planes can resonate and radiate better in certain bands.
- Common-mode currents: small asymmetries turn differential-mode currents into current flowing along a cable in the same direction, which radiates far more efficiently.
Ruling out false positives
Part of what is measured does not come from the equipment under test: radio stations, communications and other equipment in the laboratory or the surroundings. This is verified with the equipment turned off and by comparing measurement environments. The measurement is also influenced by the distance, the antenna height, the cable arrangement and the operating mode of the equipment.
What to check first
- Confirm that the peak disappears with the equipment turned off and that it is repeatable.
- Identify its origin by turning off or disabling subsystems, or with near-field probes.
- Check whether the peak is a harmonic of a known frequency (clock, switching).
- Test with cables removed, shortened or fitted with ferrites to see whether the emission depends on them.
- Check shield continuity, contact between covers and chassis, and filtering at inputs and outputs.
How it is corrected
Depending on the cause: line filters, ferrites, improved shield connection, a change in board layout, reduced edge rates or modulation of the clock frequency to spread the energy over a wider band. It is better to tackle the source than to correct the effect, and to repeat the measurement after each change.