Why does equipment fail emissions even when its design is correct?

Because the schematic does not include what determines the emission: current return paths, parasitic inductances, loop area, connected cables and the mechanical assembly. An electrically correct circuit can be a good antenna if its physical construction allows it.

The schematic does not describe the emission

A design can work without errors and still emit too much. The schematic describes the intended connections; emission depends on phenomena the schematic does not show: the actual path of return currents, parasitic capacitances and inductances, loop area and the way cables couple to the circuit.

Common causes

  • Interrupted return path: a fast signal crossing a slot in the reference plane forces the current to go around it, forming a large loop that radiates.
  • Common-mode current into the cables: a small potential difference in the reference is enough to excite a cable as an antenna, even if the wanted signal is well designed.
  • Edges faster than necessary: the spectrum depends on the rise time; a fast output with high current produces harmonics up to high frequencies.
  • Switching power supply: the switching loop, the heat sink and the transformer produce conducted and radiated emission.
  • Enclosure with apertures: seams, slots and cables passing through the wall let internal noise escape.
  • Dependence on configuration: the length and arrangement of the cables in the test affect the results, and a configuration different from the one in the design lab changes the emission.

What to check first

  1. Compare the failing frequencies with clocks, power supplies and their harmonics to identify the source.
  2. Measure with near-field probes to locate the origin on the board or cable.
  3. Use a current clamp to find out whether a cable carries significant common-mode current.
  4. Test with and without ferrites, with shorter cables or with their position changed, to see whether the result changes.
  5. Check the bonding of shields and the chassis connection.

Why units vary

Two units of the same product can emit differently because of tolerances in components, assembly or cable length. A design that passes with little margin on a prototype can fail on another unit. That is why a margin is sought and more than one sample is evaluated when possible.

A design that is correct from a circuit standpoint also requires a design that is correct from an electromagnetic standpoint.