Why Does Permittivity Change with Aging?

Permittivity changes with aging because the material changes chemically and physically: it absorbs water, oxidizes, loses additives, degrades or continues to cure, and each of these processes alters polarization and losses.

Permittivity reflects structure

Permittivity depends on how many dipoles there are, how freely they can move and how densely they are packed. If aging changes any of these factors, the permittivity shifts. This is not an instrument fault: it is a sign that the material is no longer the same.

Processes that change it

  • Moisture absorption: water, which is highly polar, raises the real permittivity and the losses. This is the most frequent effect and is largely reversible if the material is dried.
  • Oxidation: introduces polar groups, such as carbonyls, into the polymer chain. It raises losses, especially in nonpolar materials that originally had very low losses.
  • Residual curing: in thermosetting resins, curing can reach completion over time or with heat, which restricts dipole mobility and shifts the relaxations.
  • Loss of plasticizers or additives: changes mobility and density.
  • Changes in crystallinity or physical relaxation: the rearrangement of the chains modifies the free volume.
  • Degradation and chain scission: generates polar fragments and decomposition products.

How to separate the causes

Measuring the permittivity before and after drying the sample separates what is due to water from what is permanent. If losses increase while the permittivity barely changes, this points to oxidation or contamination. If the relaxations shift with temperature, there are changes in curing or plasticization. The dielectric spectrum over frequency and temperature is the most revealing tool.

What it means for design

In radio-frequency circuits, permittivity drift shifts the frequencies of filters and antennas. That is why stability is evaluated with aging tests and the material is specified by its stable behavior, not just by its initial value.

When it is a concern

A small change that stabilizes may be acceptable; a continuous change that does not stop indicates an ongoing degradation process and justifies investigating the cause.