The basic reason: density
A gas denser than air tends to sink and travel along the floor. Density relative to air is what governs the behavior: propane, butane, carbon dioxide and hydrogen sulfide are denser than air and concentrate low down; methane and hydrogen are lighter and rise. The vapor of many solvents and of gasoline is also denser and seeks the lowest level.
Why it does not mix on its own
In an open space, wind and turbulence mix the gas with the air. In a pit, sump, tank or manhole there is no air current: the air is almost still, so diffusion is slow and the dense gas forms a layer. The concentration can be low at the top and dangerous at the bottom, with a gradual boundary between the two.
Other factors that cause stratification
- Temperature: a cold gas is denser; a hot gas tends to rise until it cools.
- Shape of the enclosure: recesses, sumps and corners retain gas.
- Sources at the bottom: sediment, sludge or organic matter that release gas from below.
- Poorly directed ventilation: moving air through the upper part without sweeping the bottom.
What an engineer sees in practice
An acceptable reading at the access opening that contrasts with a dangerous reading a few meters down. That is why measurements are taken at several levels, from top to bottom, and the expected gas is taken into account: for a heavy gas the focus is on the bottom; for a light gas, on the ceiling. In leak detection, sensors are placed according to the density of the gas being monitored, not at any random point.
An example
In a maintenance pit with liquefied petroleum gas, the detector next to the edge reads little, but the gas is concentrated at the bottom. A person going down passes from an almost normal atmosphere to a dangerous one in a few steps. Hence the rule of sampling at different heights and times, and of ventilating so that the bottom is swept.
Entry into spaces with an atmospheric hazard must be carried out by qualified personnel and in accordance with current regulations.