Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Why do hot spots form in a module?

    A hot spot appears when a cell or group of cells dissipates power instead of generating it, normally because it becomes reverse biased within a string: the current from the healthy cells forces it to heat up.

  • Why do insulation readings change with ambient humidity?

    Insulation readings change with ambient humidity because moisture forms a conductive film on surfaces and can be absorbed by hygroscopic materials, opening leakage paths that reduce the measured resistance without the internal insulation necessarily being damaged.

  • Why do laboratory results fail because of poor sampling?

    Results fail because of poor sampling because the sample stops being representative: it gains or loses water and gases, picks up dirt from the sampling point, or mixes with what is in the container.

  • Why do long cables radiate more?

    Because a long cable picks up and emits energy more efficiently when its length is a significant fraction of the wavelength. At low frequencies, a short cable is a poor radiator; as frequency increases, the same cable eventually resonates and becomes an efficient antenna.

  • Why do machine bolts come loose?

    Bolts come loose because vibration, cyclic stresses and surface settling reduce the clamping force until the joint no longer maintains it, and once it loses preload, movement and loosening accelerate.

  • Why do multiple deaths occur in confined spaces?

    Multiple deaths occur in confined spaces because someone who sees a coworker collapse goes in to rescue them without protection and is exposed to the same atmosphere or hazard that incapacitated them, often within seconds.

  • Why Do Nonlinear Loads Distort the Waveform?

    A nonlinear load distorts the waveform because its current is not proportional to the applied voltage: it draws current during only part of the cycle, and that non-sinusoidal current breaks down into harmonics of the fundamental frequency.

  • Why do oil leaks occur in a transformer?

    Oil leaks originate mainly at aged gaskets, welds or flanges that have lost their tightness, because of thermal cycling, vibration and corrosion; they indicate a loss of tightness and can let moisture in.

  • Why do power factor correction capacitors heat up?

    Power factor correction capacitors heat up because they absorb harmonic currents that add to the fundamental, because of overvoltage, because of resonance with the grid, or because of internal losses in an aged or poorly ventilated capacitor.

  • Why do reflections cause false positives in thermography?

    Because low-emissivity surfaces, such as polished metal, reflect radiation from their surroundings, and the camera cannot distinguish between what the object emits and what it reflects from a hotter nearby source.

  • Why do residual-current devices trip with no apparent fault?

    A residual-current device can trip with no apparent fault because it measures the sum of leakage currents, and that sum can grow because of filters, electronic equipment, or transients without any localized insulation damage.

  • Why do solder joints crack after temperature cycling?

    Solder joints crack because the joined materials expand differently when the temperature changes, which imposes cyclic strains on the joint that accumulate fatigue until a fracture occurs.

  • Why do two analyzers report different harmonics in the same installation?

    Two analyzers can report different harmonics in the same installation because of differences in connection point, synchronization, calculation window, component grouping, averaging interval, accuracy class or sensors, or even because the load changed between measurements.

  • Why do two calibrations of the same instrument not match?

    Two calibrations of the same instrument can differ because of real instrument drift, because of differences in method, points, conditions and standards, or simply because the difference fits within the stated uncertainties.

  • Why Does a Badly Installed Connector Cause Reflections on an Antenna Line?

    A badly installed connector creates an impedance discontinuity that reflects part of the signal; on a cable and antenna analyzer it appears as a localized reflection peak at the distance of the connector and as degraded return loss.

  • Why does a battery lose capacity with cycling?

    A battery loses capacity with cycling because side reactions consume active lithium, the electrode material degrades, and lithium plating and mechanical stresses reduce the share of material that can exchange charge.

  • Why does a bearing fail from poor lubrication?

    A bearing fails from poor lubrication because, without a film separating the surfaces, metal-to-metal contact generates friction, heat and wear that damage the raceways and rolling elements until fatigue and cracks develop.

  • Why does a blurry thermal image ruin a diagnosis?

    Because in an out-of-focus image the energy of a hot spot is spread over several neighboring pixels, which lowers the measured temperature and can lead to misclassifying the severity of a fault.

  • Why does a bushing fail?

    Bushings fail mainly because of moisture penetrating the insulation, partial discharges that erode it, overheated connections and external contamination, and the failure can be violent.

  • Why does a calibrated instrument still give wrong readings?

    A calibrated instrument can give wrong readings because calibration only describes its state at one moment and under specific conditions: drift, damage, misuse, environmental effects, incorrect installation or an unsuitable method can all appear afterward.

  • Why does a calibration certificate lose its validity?

    A calibration certificate has no expiration date of its own; it loses its practical validity when the instrument changes state, when the interval set by the user or by the applicable requirement runs out, or when the standard used is no longer traceable.

  • Why does a camera show wrong temperatures in the sun?

    Because the sun heats surfaces and reflects off them, and the camera measures both effects along with the equipment's own heat; in addition, sun on the camera itself alters its behavior.

  • Why does a charger suddenly stop charging?

    A charger suddenly stops charging because a protection device tripped, temperature forced it to stop or reduce power, communication with the vehicle was lost, the vehicle asked to stop charging, or there was a grid disturbance.

  • Why does a charging connector heat up?

    A charging connector heats up through Joule heating in a high contact resistance, caused by wear, dirt, oxidation, poor insertion, loose terminals or a cable undersized for the current.

  • Why Does a Circuit Breaker Trip Without an Apparent Overload?

    A circuit breaker can trip without a sustained overload because it responds to peaks, heat, ground leakage or incipient faults that a multimeter does not show at a given instant.

  • Why does a connector degrade?

    A connector degrades because its contact interface loses pressure or becomes contaminated: wear, corrosion, micromotion and temperature raise the contact resistance until they cause intermittent faults or heating.

  • Why Does a Contactor Fail from Sparking at Its Contacts?

    Sparking at a contactor's contacts indicates that an arc is forming on closing or opening, usually because of low coil voltage, contact bounce, wear, or a load more severe than its utilization category allows.

  • Why does a DC connector fail?

    A DC connector almost always fails because of high contact resistance: a defective crimp, a poorly mated joint, moisture or connectors that are not compatible. That resistance heats up, gets worse over time and can end in an arc.

  • Why does a fan vibrate after maintenance?

    A fan vibrates after maintenance because its balance, alignment, mounting or clearance may have been altered during the work: cleaning, replacing or reinstalling an impeller or a bearing changes the mass distribution or the geometry.

  • Why does a gas detector read zero in a hazardous atmosphere?

    A gas detector can read zero in a hazardous atmosphere because it does not detect all gases, because its sensor is damaged, depleted or uncalibrated, or because the sample did not reach the sensor.