Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What does radiometric calibration mean?

    It means establishing, against reference sources of known temperature, the relationship between the signal the detector delivers and the temperature the camera must display, so that each pixel is a measurement and not just an image.

  • What does Section 38.3 of the UN Manual of Tests and Criteria test for batteries?

    Section 38.3 of the UN Manual of Tests and Criteria requires lithium cells and batteries to pass a series of tests simulating transport conditions, such as altitude, temperature, vibration, shock, short circuit, impact, overcharge and forced discharge.

  • What Does Short Interruption Mean Compared with Sustained Interruption?

    The difference between a short interruption and a sustained interruption is the duration of the voltage loss and how service is restored: short ones recover on their own, usually through automatic reclosing; sustained ones require subsequent action.

  • What does THD mean?

    THD is total harmonic distortion: a ratio that compares the harmonic content of a waveform with its fundamental component and sums up in a single number how far it departs from a sine wave.

  • What does the ANSI Z117.1 standard cover?

    ANSI Z117.1 is a voluntary US consensus standard that sets minimum safety requirements for entering, working in and leaving confined spaces, and it complements mandatory regulations.

  • What does the ASTM D149 dielectric breakdown standard cover?

    ASTM D149 describes how to determine the breakdown voltage and dielectric strength of solid electrical insulating materials at power frequencies, by applying an increasing voltage to a sample until it fails.

  • What does the ASTM D495 arc resistance standard describe?

    ASTM D495 describes a dry, high-voltage, low-current arc resistance test on solid insulators, which measures the time an intermittent arc takes to make the surface conductive or damage it.

  • What Does the ETSI EN 300 328 Standard Cover?

    ETSI EN 300 328 is a European harmonized standard that sets spectrum and efficient channel use requirements for wideband transmission equipment in the 2.4 GHz band.

  • What does the Federal Law on Metrology and Standardization establish?

    The Federal Law on Metrology and Standardization (Ley Federal sobre Metrología y Normalización) is the Mexican legal instrument that regulates the system of units, metrology, standardization, conformity assessment and accreditation. For its specific provisions, consult the current text.

  • What Does the IEC 60060-1 Standard on High-Voltage Techniques Cover?

    The IEC 60060-1 standard sets out general definitions, waveforms, test procedures and requirements for high-voltage test voltages: DC, AC, lightning impulse and switching impulse.

  • What does the IEC 60076 series cover?

    IEC 60076 is a series of international standards on power transformers, organized in parts covering general requirements, temperature rise, insulation, loading capability, short circuit, noise and other aspects.

  • What does the IEC 60112 tracking standard measure?

    IEC 60112 defines the method for determining the proof tracking index (PTI) and the comparative tracking index (CTI) of solid insulating materials, by subjecting their surface to voltage and to drops of a contaminant solution.

  • What Does the IEC 60153 Standard for Waveguides Cover?

    IEC 60153 is a series of standards on hollow metallic waveguides: general requirements, measurement methods and specific dimension and tolerance specifications for the most widely used waveguide types.

  • What does the IEC 60243-1 dielectric strength standard cover?

    IEC 60243-1 describes methods for determining the dielectric strength of solid insulating materials under AC voltage at power frequency, with defined electrodes, media and voltage-rise procedures.

  • What does the IEC 60529 IP code classify?

    The IEC 60529 IP code classifies the degree of protection an enclosure provides against access to hazardous parts, the ingress of solid objects and the ingress of water, but not against other hazards.

  • What does the IEC 60904-1 standard measure for the I-V curve?

    IEC 60904-1 describes how to measure the current-voltage characteristic of a photovoltaic device: it defines the procedure, the irradiance and temperature conditions, and the instrument requirements so that the curve is comparable.

  • What does the IEC 61000-4-3 radiated immunity standard cover?

    IEC 61000-4-3 describes the test method for the immunity of electrical or electronic equipment to radiated radio-frequency electromagnetic fields: how to generate and calibrate the field, how to apply it to the equipment and how to classify the result. Test levels are set by the product standard.

  • What does the IEC 61000-4-4 fast burst standard cover?

    IEC 61000-4-4 describes the immunity test for electrical fast transient bursts: the generator, the coupling networks and clamps, the arrangement over a reference plane and the classification of the result. Levels and criteria are defined by the product standard.

  • What does the IEC 61000-4-5 surge standard cover?

    IEC 61000-4-5 describes the immunity test for unidirectional surges caused by switching and by indirect lightning: the combination wave generator, the coupling networks, the line-to-line and line-to-ground modes, and the evaluation. Levels are set by the product standard.

  • What Does the IEC 61169 RF Connector Series Cover?

    The IEC 61169 series brings together international specifications for radio-frequency coaxial connectors: a generic part with definitions and test methods, and specific parts for each connector family.

  • What does the IEC 61215 standard test in modules?

    The IEC 61215 standard defines a test sequence for qualifying the design of a terrestrial photovoltaic module: it verifies that the module's electrical performance and integrity are maintained after it is subjected to representative environmental and mechanical stresses.

  • What does the IEC 61730 standard evaluate regarding safety?

    The IEC 61730 standard evaluates the safety of a photovoltaic module: that its construction and materials withstand the risk of electric shock, fire and mechanical injury throughout its service life, and it defines tests to verify this.

  • What does the IEC 61851 conductive charging series cover?

    The IEC 61851 series sets out the requirements for electric vehicle conductive charging systems: charging modes, the control pilot function, station electrical safety, and specific requirements for DC charging.

  • What does the IEC 62109 standard cover for inverters?

    The IEC 62109 standard deals with the safety of power converters for photovoltaic systems, including inverters: it requires them to protect against electric shock, hazardous energy, fire and failures, and to detect and handle ground faults.

  • What does the IEC 62196 connector series define?

    The IEC 62196 series defines the requirements for plugs, socket outlets, connectors and vehicle inlets for conductive charging, including their dimensions, and the AC and DC connector types that make stations and vehicles compatible.

  • What Does the IEC 62232 Standard Assess for Base Stations?

    IEC 62232 deals with determining radio-frequency field strength, power density and specific absorption rate near radiocommunication base stations, in order to assess human exposure to electromagnetic fields.

  • What does the IEC 62305 series set out on lightning protection?

    The IEC 62305 series sets out a comprehensive approach to lightning protection: general principles, risk assessment, protection of structures against physical damage and protection of internal electrical and electronic systems.

  • What does the IEEE 1057 standard define for waveform recorders?

    The IEEE 1057 standard defines the terminology and test methods for characterizing digitizing waveform recorders, that is, instruments that convert an analog signal into a sequence of data, such as digital oscilloscopes and digitizers.

  • What does the IEEE 1241 standard provide for analog-to-digital converters?

    The IEEE 1241 standard provides terminology and test methods for analog-to-digital converters: it defines what their parameters mean and describes how to measure them, so that the specifications of different converters can be compared.

  • What Does the IEEE 145 Standard Define for Antennas?

    IEEE 145 is a document of definitions of terms for antennas: it establishes a common vocabulary for concepts such as gain, directivity, radiation pattern and polarization, so that results are interpreted the same way by laboratories and manufacturers.