What it evaluates
The standard deals with the susceptibility of the surface of a solid insulator to forming conductive paths, known as tracking, under the combined action of an electric field and wet contamination. Its purpose is to compare materials under defined conditions, not to reproduce a real environment exactly.
Two indices
- PTI (proof tracking index): the voltage at which the material withstands the test with the specified number of drops, for a given specimen or set.
- CTI (comparative tracking index): a voltage value assigned to a material after several specimens are tested, which places it in a category. This is the figure that usually appears on datasheets.
How the test proceeds, in general terms
Two electrodes rest on the flat surface of the specimen. AC voltage is applied and, at regular intervals, a drop of electrolyte solution falls between the electrodes. It is determined whether the leakage current exceeds a threshold or the material ignites. The procedure is repeated at various voltages to locate the limit value. The details —electrodes, solution, intervals, number of drops— are in the standard and must be taken from its current edition.
How the result is used
- To classify materials into categories that feed into the selection of creepage distances in insulation coordination standards.
- To control quality and compare formulations, fillers and flame retardants.
- As an acceptance criterion in product standards.
What it does not measure
It does not evaluate resistance to high-energy discharges or long-term outdoor erosion; other tests exist for that, such as inclined-plane tests. Nor does it replace validation of the finished product, whose geometry influences its behavior.
How to read a value
Check which color, thickness and formulation it corresponds to, because these factors change the index. A higher CTI indicates better resistance, but the comparison is legitimate only between values obtained with the same method.
High voltage
Although the test voltages are at mains level, work with energized equipment must be carried out by qualified personnel and in accordance with the applicable regulations.