Why it exists
Section 38.3 is a transport requirement, not a battery performance test. Its purpose is to show that a lithium cell or battery does not become a hazard during transport by air, sea, rail or road. It is part of the classification of dangerous goods and is required for each cell and battery type before shipment. The scheme is summarized here; the exact parameters of each test are in the edition of the manual in force.
Which tests it includes
- Altitude simulation: reduced pressure to check that there are no leaks.
- Thermal cycling: abrupt changes between high and low temperature.
- Vibration: simulates vibration during transport.
- Shock: brief, high-magnitude accelerations.
- External short circuit: the terminals are short-circuited.
- Impact or crush: depending on the cell size.
- Overcharge: applicable to rechargeable batteries.
- Forced discharge: applicable to primary cells.
The tests are applied to samples at different states of charge and in defined sequences, some with the same samples subjected to several tests in a row.
How the result is judged
The criteria are qualitative and based on verification: there must be no leakage, venting, disassembly, rupture or fire, and the open-circuit voltage is checked to confirm that it does not drop beyond what is permitted after certain tests. A quality management system and a test summary are also required.
What it does not demonstrate
A battery passing 38.3 does not mean that it meets the safety requirements in a vehicle. The section does not assess service life, capacity, prolonged thermal abuse or propagation between cells in a pack. Other specific tests are used for those aspects. These tests involve a fire risk and must be performed by qualified laboratories and personnel.