What it establishes
The standard sets a method for obtaining the I-V curve of cells and modules, so that two laboratories can obtain comparable results. It covers measurements both under a solar simulator and under natural light, and it indicates what must be controlled and recorded in each case.
What must be controlled
- The irradiance, measured with a calibrated photovoltaic reference device suited to the type of device being measured.
- The device temperature, measured representatively, because voltage depends strongly on it.
- The uniformity and stability of the light source.
- The sweep speed, which must be compatible with the response time of the device.
Why sweep speed matters
Some high-capacitance modules, for example with certain cell technologies, respond slowly. If the sweep is too fast, the measured curve depends on the sweep direction and does not represent steady-state behavior. A short-pulse simulator must be adjusted to this characteristic.
What is obtained from the curve
The curve is used to determine the short-circuit current, the open-circuit voltage, the maximum power point and the fill factor. To refer the results to standard conditions, temperature and irradiance correction procedures are applied, defined in other standards of the same family.
How uncertainty is interpreted
The result is only as good as the irradiance and temperature measurements. Small calibration differences in the reference device carry over directly to the calculated power. For that reason, a report must state the uncertainty and the traceability of the standards used.
Note on editions
This guide describes only the general scope of the standard. The requirements, the tests and their order change between editions, so consult the current edition and the one required by the contract or the authority.