What it sets out to demonstrate
The standard seeks to verify that a module design can operate outdoors for a long time without degrading unacceptably. It does not predict the exact service life; instead, it subjects samples to accelerated stresses and verifies that power and basic safety remain within acceptance criteria.
Types of test it covers
- Visual inspection and power measurement before and after each sequence, to quantify changes.
- Insulation tests and wet leakage current tests.
- Thermal cycling and damp heat and humidity freeze tests, which punish encapsulation materials and solder joints.
- Static mechanical load and, depending on the technology, impact tests such as hail.
- Ultraviolet light exposure and hot spot testing.
- Verification of the bypass diodes.
How a result is interpreted
Each test ends with a comparison against the initial measurement. A power drop below the criterion, major visual defects or insulation failures mean the design does not qualify. That is why the report includes measurements taken before and after, not just a verdict.
What it does not guarantee
Having met the standard does not ensure that every module manufactured is the same as the one tested, or that it will withstand any environment. Qualification applies to a defined design and bill of materials; changes of supplier or process may require new tests. Nor does it replace production quality control or incoming lot inspection.
Relationship with other standards
The electrical safety of the module is covered by a different standard, focused on the risk of electric shock and fire. Design qualification and safety qualification complement each other, and a module usually presents both.
Note on editions
This guide describes only the general scope of the standard. The requirements, the tests and their order change between editions, so consult the current edition and the one required by the contract or the authority.