General scope
Part 1 of the IEC 60243 series deals with determining the dielectric strength, or electric breakdown field strength, of solid electrical insulating materials under AC voltage at power frequencies. Other parts of the series address impulses and DC voltage. The standard aims to make results from different laboratories comparable because they are obtained under equivalent conditions.
What it standardizes
- Electrodes: geometries and dimensions suited to the material and its thickness, with edges that limit field concentration.
- Surrounding medium: when to test in air and when in an insulating liquid to prevent edge discharges.
- How the voltage is raised: rapid-rise, stepwise or withstand tests, each with its own meaning.
- Conditioning: temperature and humidity prior to the test.
- Number of specimens and statistical treatment: because dielectric strength shows scatter, several specimens are required.
- Report: data that must be recorded so the test can be reproduced.
What it does and does not provide
The standard makes it possible to compare materials and to control the quality of a batch. It does not guarantee that the value obtained is what the material will withstand in an installation, where thickness, geometry, partial discharges, aging and combined stresses all play a part. That is why the measured dielectric strength is a starting point for design, which applies margins.
How to use it well
- Consult the current edition and the product standards that refer to it, because these may set their own conditions.
- State in the report the type of electrodes, the medium, the ramp and the conditioning.
- Do not compare values obtained with different configurations.
Safety
The test is performed at high voltage. It must be carried out by qualified personnel, following the applicable electrical safety regulations and the laboratory’s procedures.