Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- What is a capacitance meter with ESR?
A capacitance meter with ESR measures the value of a capacitor and its equivalent series resistance, which makes it possible to detect degraded capacitors that a capacitance meter alone does not reveal.
- What Is a Channel Emulator?
A channel emulator is an instrument that reproduces, in a controlled and repeatable way, the effect of a real radio channel, such as attenuation, multipath delays, fading and noise, without having to go out into the field.
- What is a Class A power quality analyzer?
A Class A power quality analyzer is an instrument that meets the strictest method and uncertainty requirements of IEC 61000-4-30, so that two Class A instruments measuring the same signal give comparable results.
- What is a climatic chamber?
A climatic chamber is an insulated enclosure that controls temperature, and on many models humidity, to expose products to defined, repeatable environmental conditions.
- What Is a Coaxial Termination Load?
A coaxial termination load is a one-port component that presents a resistance equal to the characteristic impedance of the line and absorbs the energy reaching it, so that almost nothing is reflected.
- What is a common cause failure?
A common cause failure is a single root cause that makes several items fail at the same time, including those installed as redundant, which is why it reduces the protection that redundancy provides.
- What is a component curve tracer?
A component curve tracer applies a voltage sweep to a device and displays its current-versus-voltage curve on screen, revealing its behavior without having to power the circuit.
- What is a component’s failure rate?
A component's failure rate is how often it fails per unit of time among those still working; how it evolves over time explains why equipment fails.
- What is a conductive ground enhancement backfill used for?
A conductive ground enhancement backfill reduces the local resistance between the electrode and the ground by replacing the immediately surrounding soil with a low-resistivity material that also retains moisture.
- What is a counterpoise in a grounding system?
It is a buried horizontal conductor, normally radial or parallel to a line, that is added to the electrode to disperse current when deep electrodes cannot be driven or when the impedance to lightning discharges must be reduced.
- What is a data acquisition system?
A data acquisition system conditions, samples and digitizes signals from sensors or instruments, then stores them or sends them to a computer for logging, analysis or control.
- What is a DC-DC converter in an electric vehicle?
A DC-DC converter in an electric vehicle steps the high voltage of the traction battery down to the level of the low-voltage auxiliary network, performing the role of the alternator in a combustion vehicle.
- What is a decision rule with a guard band?
A decision rule with a guard band accepts or rejects a measurement result using an acceptance limit offset from the tolerance limit, so that measurement uncertainty reduces the risk of accepting an out-of-tolerance instrument.
- What is a delta T in thermography?
It is the difference between the temperature measured at a point of interest and that of a reference, which can be the ambient, a similar component under the same conditions, or the same equipment in another inspection.
- What is a dielectric strength tester?
A dielectric strength tester is an instrument that applies an AC or DC voltage, raised in a controlled way, to insulation or a sample, and detects when the current rises sharply, which indicates breakdown or excessive leakage.
- What is a dielectric test cell with guard electrodes?
A dielectric test cell with guard electrodes is a parallel-plate sample holder in which the measuring electrode is surrounded by a guard ring at the same potential, so that the measured current passes only through the volume of the sample.
- What is a differential probe?
A differential probe measures the voltage difference between its two inputs and rejects what they have in common, making it possible to measure between two points that are not referenced to the oscilloscope's ground.
- What Is a Disruptive Discharge?
A disruptive discharge is the sudden collapse of the insulating capability between two electrodes, when a complete conductive channel forms between them; gases and liquids usually recover, while a solid is left with permanent damage.
- What is a dry-block calibrator?
A dry-block calibrator is a temperature-controlled metal block with holes, heated or cooled, into which sensors are inserted to calibrate or verify them without the need for liquids; it is practical and portable.
- What is a dynamometer test bench for electric motors?
A dynamometer test bench couples the electric motor to a load machine that sets its speed or torque, and it measures torque, speed and electrical power to obtain curves and efficiency maps.
- What is a fault event recorder?
A fault event recorder is a device that continuously monitors electrical signals and saves, with a timestamp, the data from the moments before, during and after a disturbance.
- What is a fault tree?
A fault tree is a logic diagram that starts from an undesired event and breaks down, using AND and OR gates, the combinations of failures that can produce it.
- What is a ferroelectric material?
A ferroelectric material has a spontaneous electric polarization that can be reversed by an external field, which is why it shows hysteresis and a very high permittivity near its transition temperature.
- What is a fluid calibration bath?
A fluid calibration bath is a tank of stirred, temperature-controlled liquid in which sensors are immersed so that all of them are at the same temperature while they are compared with a reference thermometer.
- What is a forced convection oven for testing?
A forced convection oven is a heated enclosure with a fan that recirculates the air to achieve a uniform temperature, and it is used for thermal aging tests and for drying and curing samples.
- What is a four-wire connection?
A four-wire connection measures a resistance using one pair of leads to inject the current and a separate pair to measure the voltage, so that the resistance of the leads and contacts does not enter the result.
- What is a frequency-sweep dielectric analyzer?
A frequency-sweep dielectric analyzer measures the complex permittivity of a material across a wide frequency range, and shows how its polarization and conduction mechanisms respond, from slow to fast relaxations.
- What is a functional test (bump test) of a detector?
A functional test (bump test) briefly exposes a gas detector to a known concentration to check that its sensors respond and its alarms activate, but it does not adjust the calibration.
- What is a furan?
A furan is a cyclic organic compound containing one oxygen atom; in transformers, furan derivatives dissolved in the oil are markers of degradation of the cellulose insulation.
- What is a ground inspection well or pit?
A ground inspection well or pit is a box or tube with a cover, placed over the connection point of an electrode, that makes it possible to see, measure and maintain the connection without excavating.