Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What does the IEEE 1451 smart transducer series propose?

    The IEEE 1451 series defines a common way to describe sensors and actuators and connect them to a network, so that each transducer identifies itself and delivers data in a standard format without manual configuration.

  • What does the IEEE 1584 guide calculate?

    The IEEE 1584 guide provides calculation models for estimating arcing current, incident energy and the arc flash boundary from system data, equipment configuration and the protection's clearing time.

  • What Does the IEEE 1785 Standard for Waveguides Define?

    IEEE 1785 is a family of standards that establishes band designations, dimensions, flange interfaces and performance requirements for metallic rectangular waveguides at very high millimeter-wave and submillimeter-wave frequencies.

  • What does the IEEE 181 pulse measurement standard cover?

    The IEEE 181 standard defines the terms and algorithms used to measure transitions, pulses and related waveforms, such as rise time, overshoot or pulse width, so that measurements made on different instruments are comparable.

  • What Does the IEEE 242 Protection Standard Cover?

    IEEE 242 is a recommended practice on the protection and coordination of industrial and commercial power systems: it explains how to select and set protective devices so that they clear faults with the least possible damage and interruption.

  • What Does the IEEE 400 Guide for Cables in the Field Describe?

    The IEEE 400 guide provides direction on field testing and insulation evaluation of shielded power cable systems, describing test types, methods and their application; it is a guide, not an acceptance specification.

  • What Does the IEEE 43 Guide for Rotating Machines Cover?

    IEEE 43 is a recommended practice that describes how to measure and interpret the insulation resistance of rotating machine windings, including the polarization index.

  • What does the IEEE 80 substation guide cover?

    The IEEE 80 guide deals with safety in the grounding of AC substations: how to calculate tolerable voltages, grid resistance, ground potential rise, and step and touch voltages.

  • What Does the IEEE 802.11 Family Define in General?

    The IEEE 802.11 family defines how the devices of a wireless local area network communicate by radio: the physical layer, meaning modulation and channels, and medium access control, which governs who transmits and when.

  • What Does the IEEE 802.15.4 Standard Cover?

    IEEE 802.15.4 defines the physical layer and medium access control of low-rate, low-power, short-range wireless networks; it does not define the complete network or the application.

  • What does the IEEE C57.12.90 test code describe?

    IEEE C57.12.90 is a test code for liquid-immersed distribution and power transformers and regulators: it defines how routine and design tests are performed and calculated.

  • What does the IEEE C57.152 field testing guide set out?

    IEEE C57.152 is a guide to diagnostic field testing of fluid-filled transformers, regulators and reactors: it describes which tests to apply and how to perform and interpret them.

  • What does the ISO 20816 series set out for machine vibration?

    The ISO 20816 series sets out how to measure and evaluate the mechanical vibration of machines, with parts for different machine types, and defines the quantities, the measurement positions and the criteria used to classify vibration condition.

  • What does the neutral grounding scheme of an installation mean?

    The neutral grounding scheme describes how the source neutral is connected to ground and how the metal parts of the installation are grounded, and the fault current and the way of protecting the installation depend on it.

  • What Does the Oil Do in a Transformer?

    Transformer oil performs several functions at once: it provides electrical insulation, carries heat from the core and windings to the radiators, impregnates the paper and serves as a source of diagnostic information.

  • What effects does electric current have on the human body?

    The effects of current on the body depend on its magnitude, how long it flows, its path and whether it is direct or alternating; voltage matters only because, together with the body's resistance, it determines that current.

  • What features should a multifunction energy meter have?

    A multifunction energy meter must accurately measure voltage, current, power, energy and power factor, and also offer the logging, communication and configuration the application demands.

  • What guidance ASME B40.100 gives on pressure gauges

    ASME B40.100 deals with indicating pressure gauges with elastic elements: their types, accuracy classes, dimensions, construction and marking, as a general reference for manufacturers and users.

  • What guidance does ASTM E1934 give for electrical and mechanical equipment?

    ASTM E1934 is a guide on how to examine electrical and mechanical equipment with infrared thermography: what to consider when planning, performing, documenting, and reporting the inspection.

  • What guidance does IEC 60812 give on failure mode analysis?

    IEC 60812 is an international standard that gives guidance on how to plan and apply failure modes and effects analysis, and its variant with criticality, to systems, products and processes.

  • What guidance does IEEE 142 give on industrial grounding?

    IEEE 142, known as the Green Book, gives guidance on grounding industrial and commercial systems: system grounding, equipment grounding, static, lightning protection and considerations for electronic equipment.

  • What guidance does IEEE C57.104 give on gases in transformers?

    IEEE C57.104 is a guide to interpreting the gases generated in oil-immersed transformers, with criteria based on concentration, generation rate, and fault type for deciding on follow-up actions.

  • What guidance does ISO 13373-1 give on monitoring?

    ISO 13373-1 offers general guidance for machine condition monitoring using vibration: how to plan the program, choose parameters and transducers, and acquire and manage data consistently.

  • What guidance does the IEEE C57.91 loading guide give?

    IEEE C57.91 is a guide on how to estimate temperatures, insulation aging and loading capability of mineral-oil-immersed transformers under different load cycles and ambient conditions.

  • What Is a Balun Used For?

    A balun is used to connect an unbalanced line, such as a coaxial cable, to a balanced antenna or load, preventing common-mode currents from flowing on the cable shield and altering the pattern and impedance.

  • What is a battery emulator?

    A battery emulator is a programmable DC power supply that reproduces the electrical behavior of a battery, voltage according to state of charge and internal resistance, and can also absorb energy to test chargers and converters without a real battery.

  • What is a battery module compared with a pack?

    A battery module is a set of cells connected and held in a structure with sensing, and a pack is the complete system that groups several modules with a management system, contactors, protections, cooling and an enclosure.

  • What is a borescope used for in diagnostics?

    A borescope is a tube with a camera and a light, rigid or flexible, that allows the inside of inaccessible cavities to be visually inspected without disassembling the equipment.

  • What is a Buchholz relay for?

    The Buchholz relay detects accumulated gas or a sudden surge of oil in the pipe between the tank and the conservator, and gives an alarm or trips on internal faults.

  • What Is a Busbar or Bus?

    A busbar, or bus, is a rigid conductor or a set of them that gathers and distributes current among several circuits connected at the same electrical point; in network studies, “bus” also designates that node in the model.