Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is cell self-discharge?

    Self-discharge is the gradual loss of charge in a cell at rest, with no load connected. It is caused by parasitic internal reactions and small leakage currents, and it increases with temperature.

  • What is channel bandwidth?

    Channel bandwidth is the range of frequencies assigned to or occupied by a signal for transmission; it limits the maximum possible data rate and must be narrow enough not to interfere with neighboring channels.

  • What Is Coincident Demand?

    Coincident demand is the maximum of the sum of several loads measured at the same instant, and it is always less than or equal to the sum of their individual maximum demands, because peaks rarely occur at the same time.

  • What is common impedance coupling?

    Common impedance coupling occurs when two circuits share a section of conductor, such as a ground or a power supply, and the current of one produces a voltage drop across that shared impedance that appears as noise in the other.

  • What is common-mode rejection?

    Common-mode rejection is the ability of a differential instrument or amplifier to ignore the signal that appears equally on both inputs and respond only to the difference between them.

  • What is condition-based maintenance?

    Condition-based maintenance intervenes on equipment when a measurement shows that its condition is deteriorating, not on a fixed calendar or after a breakdown.

  • What is considered a confined space?

    A confined space is a place large enough for a person to enter and work in, with limited means of entry and exit, and not designed for continuous occupancy; its conditions, not its size, are what make it dangerous.

  • What Is Core Saturation?

    Core saturation occurs when the flux exceeds the limit the steel can carry in proportion to the current: permeability then falls, the magnetizing current spikes and the waveform becomes distorted.

  • What Is Corrosive Sulfur in Oils?

    Corrosive sulfur in oil is the presence of certain sulfur compounds that react with copper and form copper sulfide, a material that deposits on the insulating paper and can cause dielectric failures.

  • What is critical speed?

    The critical speed of a rotor is the rotational speed that coincides with one of its natural frequencies, at which vibration increases noticeably because the rotor excitation enters into resonance with the system.

  • What is depth of discharge?

    Depth of discharge is the fraction of a battery's capacity that has been drawn from full charge; it is the complement of state of charge and largely determines wear per cycle.

  • What Is Dielectric Absorption?

    Dielectric absorption is the gradual increase in the polarization of an insulator when DC voltage is applied; it shows up as a current that decays over time and is used to judge whether the insulation is clean and dry.

  • What is dielectric polarization?

    Dielectric polarization is the displacement or orientation of bound charges within an insulating material when an electric field is applied, and it is the reason a dielectric stores energy and increases the capacitance of a capacitor.

  • What is dielectric relaxation?

    Dielectric relaxation is the delay with which a material's polarization follows a varying electric field, due to the inertia of dipoles or charges, and it appears as a fall in permittivity and a loss maximum.

  • What Is Directivity?

    Directivity is the ratio of an antenna's radiation intensity in a given direction to the average intensity over all directions; it indicates how much the radiated energy is concentrated toward one side compared with a source radiating equally everywhere.

  • What Is Dissolved Gas Analysis?

    Dissolved gas analysis (DGA) measures the gases generated when thermal or electrical faults or cellulose degradation decompose the insulating oil, and it makes it possible to detect internal transformer problems without opening the unit.

  • What is electrical safety culture in a plant?

    Electrical safety culture is the set of shared habits, decisions and criteria that lead people to work safely even when no one is supervising them; it is not a poster or a rulebook, it is what happens under time pressure.

  • What is electromagnetic compatibility?

    Electromagnetic compatibility is the ability of equipment or a system to function satisfactorily in its electromagnetic environment without producing intolerable disturbances for others or being affected by those in its environment.

  • What is electromagnetic immunity?

    Electromagnetic immunity is the ability of equipment to keep operating without unacceptable degradation when exposed to electromagnetic disturbances such as electrostatic discharges, radio fields, fast transients or voltage dips.

  • What is emissivity and why does it matter?

    Emissivity is the ratio of the radiation a surface emits to that of a blackbody at the same temperature; it matters because low emissivity causes the camera to underestimate temperature.

  • What is equipotential bonding?

    Equipotential bonding joins the conductive parts of an installation with low-impedance conductors so that no dangerous potential differences exist between them.

  • What is equivalent-time sampling?

    Equivalent-time sampling is a technique that reconstructs a repetitive signal from samples taken over different cycles, each with a different time offset, which gives a much higher time resolution than real-time sampling allows.

  • What Is Evaluated in a Site Acceptance Test?

    A site acceptance test verifies that the transformer arrived undamaged, was installed correctly and works as specified: inspection, electrical tests, oil tests and verification of protections and accessories.

  • What Is Fade Margin?

    Fade margin is the difference, in decibels, between the signal level the receiver gets under normal conditions and the minimum level at which it still works with the required quality.

  • What is flicker and what does the severity indicator measure?

    Flicker is the visual sensation of unsteadiness in a light source caused by voltage fluctuations, and its severity is quantified with indicators obtained from a standardized flicker meter, such as short-term severity Pst and long-term severity Plt.

  • What is galvanic isolation?

    Galvanic isolation is the electrical separation between two circuits so that signal or energy passes without a direct conductive path, using transformers, optocouplers or capacitive coupling.

  • What is ground fault current and how is it limited?

    Ground fault current is the current that flows to ground when an energized conductor loses its insulation, and its value is determined mainly by the impedance through which the system neutral is grounded.

  • What is ground potential rise?

    Ground potential rise is the potential difference between the grounding system and a point of remote earth, and it results from the current entering the soil multiplied by the resistance of the system.

  • What is HALT testing?

    HALT (Highly Accelerated Life Test) is a discovery test that subjects a product to increasing stresses until it fails, in order to find its weak points and design margins, not to demonstrate a service life.

  • What is high-frequency ground impedance?

    High-frequency ground impedance is the opposition a grounding system presents to rapidly changing currents, such as those of lightning, and it differs from its resistance to low-frequency AC or to DC.