Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is a thermistor and when is it used?

    A thermistor is a resistor made of semiconductor material whose resistance changes greatly with temperature; it is used when high sensitivity is needed over a relatively narrow range, as in the thermal control of electronics and batteries.

  • What is a tolerance?

    A tolerance is the total permitted variation of a quantity around its nominal value; it defines how far a part or process can be from the desired value and still be considered acceptable.

  • What is a transformer tap selector with transition resistors?

    It is the on-load tap changer system in which a selector chooses the tap with no current flowing and a diverter switch with transition resistors makes the change without interrupting the load or short-circuiting turns.

  • What is a two-channel FFT analyzer?

    A two-channel FFT analyzer measures two signals simultaneously and calculates, in addition to the spectrum of each one, the relationships between them: relative phase, transfer function and coherence, which makes it possible to study how a system responds to an excitation.

  • What is a two-pole voltage absence tester?

    A two-pole voltage absence tester is an instrument with two probes that connect to the circuit, whose indication depends on the actual voltage between them, with a defined internal impedance that limits ghost readings.

  • What Is a Vector Network Analyzer?

    It is an instrument that generates a signal, applies it to a device and uses coherent receivers to measure the magnitude and phase of the reflected and transmitted waves, yielding the device's S-parameters as a function of frequency.

  • What Is a Vector Signal Generator?

    A vector signal generator produces radio-frequency signals with complex digital modulation, controlling amplitude, phase and frequency from I and Q samples, to stimulate receivers and components with real communication formats.

  • What is a vehicle simulator for testing chargers?

    A vehicle simulator for testing chargers is a device that imitates the vehicle toward the station: it generates the control pilot and proximity signals, emulates the battery's demand and makes it possible to induce faults.

  • What is a vibration data collector?

    A vibration data collector is a portable instrument that records vibration measurements at defined points on many machines following a route, stores them and transfers them to analysis software for viewing trends and diagnosing faults.

  • What is a vibration spectrum (FFT)?

    It is the representation of a vibration signal as a function of frequency, obtained with the fast Fourier transform, which breaks the signal down into its sinusoidal components and shows the amplitude of each one.

  • What Is a Voltage Reference Source?

    A voltage reference source is a device that delivers a very stable, known voltage, used as a standard or as a point of comparison to calibrate voltmeters, converters and other instruments.

  • What Is a Voltage Sag and What Causes It?

    A voltage sag is a brief reduction in RMS voltage lasting from half a cycle to a few seconds, and it is almost always caused by a fault or by a large inrush current flowing through a shared impedance.

  • What is a wall bushing?

    A wall bushing is a device that allows an energized conductor to pass through a grounded wall, tank or cover while insulating it electrically from that surface.

  • What is a waveguide?

    It is a hollow metal structure, normally rectangular or circular, that guides microwave electromagnetic waves with very low loss; it propagates signals only above a cutoff frequency that depends on its dimensions.

  • What Is a Wireless Protocol Analyzer Used For?

    A wireless protocol analyzer captures and decodes the frames traveling over the air, showing their fields, sequences and timing, to understand why two devices do not communicate well even though the radio signal is correct.

  • What is a working standard?

    A working standard is the standard used routinely to calibrate or verify instruments, and which is in turn calibrated against a higher-level standard to maintain traceability.

  • What is AC charging versus DC charging?

    In alternating current charging, the vehicle receives AC and its onboard charger converts it to DC; in direct current charging, the charger is outside the vehicle and delivers DC directly to the battery. What changes is where the conversion takes place and, with it, the power possible.

  • What is acceleration spectral density?

    Acceleration spectral density, or PSD, describes how the energy of a random vibration is distributed across frequencies, expressed as acceleration squared per unit of frequency.

  • What is aliasing and how is it avoided?

    Aliasing is the error whereby an oscilloscope or data acquisition unit shows a fast signal as if it were a slower one, because the sample rate is insufficient to represent it. It is avoided by sampling faster or by limiting the frequency content of the signal.

  • What is an absorbing clamp used for?

    It is used to measure the disturbance power that equipment sends along its power cord or other cables at frequencies where measuring the radiated field is inconvenient. It is slid along the cable until the maximum is found, and it replaces the antenna as the evaluation method.

  • What Is an Acoustic Partial Discharge Detector?

    An acoustic partial discharge detector uses piezoelectric sensors to pick up the sound waves produced by a partial discharge, making it possible to detect and locate defects without being affected by electrical noise.

  • What is an airline respirator?

    An airline respirator supplies breathable air from an outside source, a compressor with air treatment or cylinders, through a hose to the worker's mask, without the duration limit of a self-carried cylinder.

  • What Is an Anechoic Chamber?

    An anechoic chamber is a shielded enclosure whose walls are covered with material that absorbs electromagnetic waves, so there are no reflections and the antenna under test behaves as if it were in free space.

  • What Is an Antenna Positioner?

    An antenna positioner is an electromechanical device that rotates the antenna under test with angular precision about one or more axes, in order to record its response in each direction and build the radiation pattern.

  • What is an approach boundary?

    An approach boundary is a distance around energized parts that defines who may cross it and with what protection: the limited approach boundary, the restricted approach boundary and the arc flash boundary are distinguished.

  • What is an arc flash and why is it dangerous?

    An arc flash is a sustained discharge of current through the air between conductors or to ground, releasing intense heat, light, pressure and molten metal in fractions of a second, capable of causing serious injury.

  • What is an authorized entrant?

    An authorized entrant is the person designated to enter a permit-required confined space: they know its hazards, use the protective equipment, stay in communication and leave immediately at any sign of alarm.

  • What is an eddy current proximity sensor?

    An eddy current proximity sensor is a non-contact probe that measures the distance to a conductive metal surface by detecting how the currents induced in it alter the probe's own field.

  • What is an electrical fast transient burst?

    An electrical fast transient burst is a train of very short pulses, with nanosecond rise times, repeated in packets. It represents the noise from switching inductive loads and is used to check that equipment does not reset or lock up.

  • What is an electrically safe work condition?

    An electrically safe work condition is the state in which equipment has been disconnected from all energy sources, locked out and tagged out, tested for absence of voltage and, where appropriate, grounded, so that the work is no longer performed on energized parts.