Goal: provoke failure
Unlike a qualification test, which demonstrates that the product passes a given level, HALT seeks to make it fail. Stepped stresses are applied until the operating and destruct limits are found, and the causes of failure are analyzed. The aim is to discover design and process weaknesses while they are still cheap to correct.
Typical stresses
- Low and high temperature steps.
- Rapid temperature changes.
- High-energy, broadband multi-axis vibration, which excites many frequencies at once.
- Combined temperature and vibration.
- Supply voltage variations and other product-specific stresses.
How it is carried out
One stress is stepped at a time, operation is verified at each step, and two limits are recorded: the operating limit, where the product stops working but recovers, and the destruct limit, where it is left damaged. Each failure is investigated until its root cause is identified; it is then corrected and the test is repeated to widen the margin.
What the engineer sees
Typical findings are weak solder joints, components with tight tolerances, connectors that work loose, poorly secured cables and mechanical resonances. The result is not a life figure, but a list of weaknesses and the operating margins.
What it is not
It does not predict a service life or demonstrate conformity with a standard. Failures may be due to stresses the product would never see in service, so each finding must be assessed with engineering judgment: some are corrected and others are accepted.
Relationship to other tests
HALT is done during development. A similar test used in production, called HASS, applies more moderate stresses, defined from the HALT margins, to detect manufacturing defects without consuming service life. Neither one replaces formal product qualification.