The mechanism
Every real conductor has resistance and inductance. When a current passes through it, a voltage drop proportional to its impedance appears. If two circuits share that section, the current of one generates a voltage that the other perceives as part of its own reference or power supply. No field is needed: the coupling is conducted and direct, through the conductor itself.
Where it occurs in practice
- Shared ground return: a switching digital circuit and a sensitive analog amplifier share a return trace, and the transient current of the former modifies the reference of the latter.
- Common power supply: a motor or load driver that draws current peaks pulls down the voltage seen by a sensor connected to the same line.
- Protective conductor: long ground cables shared by several pieces of equipment.
Why it matters more at high frequency
At low frequency resistance dominates, and at higher frequencies or with fast changes, inductance dominates. The voltage induced by a fast current change in an inductance is proportional to the rate of change. For this reason, digital switching transients are a common source of ground noise, even when the resistance of the conductor is small.
What the engineer sees
The noise observed correlates with the activity of another circuit, with no relationship to nearby cables or antennas. Measured with an oscilloscope, the noise on the reference or power supply appears synchronized with the switching events. Adding shielding does not reduce it, because it is not field coupling.
How it is reduced
- Separate the returns: use different ground paths for power, digital and analog circuits, and join them at a well-chosen common point.
- Reduce the shared impedance with short, wide conductors or with continuous ground planes.
- Decouple with capacitors close to the switching devices, so that the transient current circulates locally.
- Power sensitive circuits separately or filter them.
What to check first
Trace the return path of each significant current and look for the sections shared with sensitive circuits. Most solutions consist of changing that path.