What is dielectric relaxation?

Dielectric relaxation is the delay with which a material's polarization follows a varying electric field, due to the inertia of dipoles or charges, and it appears as a fall in permittivity and a loss maximum.

The idea

When a field is applied to a material, polarization does not appear instantly. Dipoles must rotate or charges must migrate, and that takes time. If the field is removed, the polarization does not vanish all at once either. The characteristic time of this process is the relaxation time.

Debye model

The simplest model assumes a single relaxation time. It predicts that, at frequencies low relative to its inverse, the polarization follows the field and permittivity is at its maximum; at high frequencies it cannot keep up and permittivity is lower. Between these two zones, the real part of the permittivity falls and the imaginary part shows a peak. Real materials usually show broader, asymmetric peaks because they have a distribution of times, and models that include this distribution are used.

Temperature dependence

In dipolar relaxation, the higher the temperature, the more easily the molecules move and the shorter the relaxation time. The loss peak shifts toward higher frequencies on heating. This property makes it possible to sweep frequency or temperature and obtain equivalent information, and it is used to study the glass transition of polymers.

Where it is observed

  • In polar polymers, through movements of side or main chains.
  • In water and polar liquids.
  • In ceramics and glasses, through ion hopping.
  • At interfaces, through charge accumulation.

What the engineer sees

A material that performs well at one frequency can have high losses at another, because that frequency falls on the relaxation peak. An insulator that heats up in a high-frequency application normally does so because its relaxation coincides with that band. Relaxation also explains why a capacitor shows dielectric absorption.

How it is measured

With dielectric spectroscopy: frequency is swept, sometimes at several temperatures, and the real and imaginary parts of the permittivity are plotted. The characteristic times and their variation with temperature are obtained from the peaks.

How to interpret the result

The peaks are associated with specific molecular movements, and that assignment requires support from other techniques, such as thermal analysis. The result depends on moisture content, which can create or shift relaxations.