What happens at rest
Even when no current flows externally, a cell is not perfectly stable. Side reactions take place inside it, such as the slow decomposition of the electrolyte at the electrode surfaces, along with small leakage currents through the separator. These consume charge continuously, though slowly.
What it depends on
- Cell chemistry: some chemistries lose charge faster than others.
- Temperature: heat speeds up the reactions and increases self-discharge.
- State of charge: at high charge levels, parasitic reactions tend to be more intense.
- Manufacturing quality and aging, which affect the condition of the separator and the surfaces.
Normal and abnormal self-discharge
A certain amount of self-discharge is expected. A cell with a much higher rate than its peers suggests a defect, such as a metal particle causing an internal micro short circuit. In a pack, that cell discharges faster and creates imbalance, so the BMS sees it drifting lower and lower relative to the rest. This behavior is monitored because it can give advance warning of a failure.
How it is measured
The cell is charged to a defined state, left at rest at a controlled temperature, and its open-circuit voltage is recorded over a long period. The voltage drop, converted into charge loss, gives the self-discharge rate. The measurement requires thermal stability, because voltage changes with temperature, and good instrument resolution.
How to interpret the result
Each cell is compared with others from the same lot. What counts is the spread between cells more than the absolute value. Internal self-discharge must be distinguished from external loads, such as the draw of connected monitoring electronics, which also discharge the pack.