Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is an electrodynamic shaker?

    An electrodynamic shaker is an actuator that converts an electric current into mechanical force by means of a moving coil in a magnetic field, in order to vibrate products with controlled signals.

  • What is an electronic load and how does it work?

    An electronic load is an instrument that sinks current from a source under test in a controlled way, using power semiconductors that dissipate the energy as heat and that are programmed in an operating mode.

  • What Is an Electrostatic Voltmeter Used For?

    An electrostatic voltmeter measures voltage from the attractive force between charged electrodes, and is used to measure high DC and AC voltages while drawing practically no current.

  • What is an EMI receiver and how does it differ from a spectrum analyzer?

    An EMI receiver is a selective measuring instrument designed to meet the requirements of emissions standards: it has defined preselection, bandwidths and detectors. A spectrum analyzer is more general, faster and more flexible, but it needs preselection and accessories to match the reliability of the receiver.

  • What is an entry attendant?

    An entry attendant is the person who stays outside the confined space, watches over those working inside, keeps in communication with them and activates rescue in an emergency, without ever entering the space.

  • What is an equipment voltage sag tolerance curve?

    An equipment voltage sag tolerance curve is a graph of voltage magnitude against duration that marks out the zone in which a type of equipment usually operates without problems and the zones where it may fail, and it is used to assess the effect of recorded events.

  • What is an EUT?

    EUT stands for "equipment under test": the specific product, in a defined configuration, that is subjected to an emission or immunity test.

  • What is an I-V curve tracer?

    An I-V curve tracer is an instrument that sweeps the load of a module or string from short circuit to open circuit and records current and voltage, together with irradiance and temperature, to show its actual performance.

  • What is an infrared inspection window?

    An infrared inspection window is a panel permanently installed in an equipment enclosure, transparent to infrared, that allows inspection with the camera without opening the switchboard.

  • What is an insulated hot stick?

    An insulated hot stick is a long-handled tool made of dielectric material that makes it possible to operate, test or handle energized equipment while keeping a safe distance between the hands and live parts.

  • What Is an Insulator and What Is a Conductor?

    An insulator is a material with almost no free charges that can move under an electric field, so it conducts very little current; a conductor has mobile charges in abundance and conducts easily.

  • What is an intermittent fault?

    An intermittent fault is one that appears and disappears with no obvious pattern; it is due to a condition that is only met occasionally, such as a defective contact, a thermal effect or vibration.

  • What is an isolated ground and when is it used?

    An isolated ground is an equipment grounding conductor insulated from the metal structure of the panel or conduit but connected to ground at the origin of the installation; it is used to reduce electrical noise in sensitive equipment.

  • What is an isotropic radiator?

    An isotropic radiator is an ideal, lossless point antenna that radiates the same intensity in all directions; it does not physically exist, but it serves as a reference for expressing directivity and gain.

  • What is an oil filtration machine?

    An oil filtration machine is a mobile unit that pumps oil through filters, and in some models through a heater and a vacuum chamber, to remove particles, water, and gases from insulating oil.

  • What is an open-ended coaxial probe?

    An open-ended coaxial probe is a length of coaxial line whose end is pressed against the material; the reflection of a microwave signal depends on the permittivity of what it touches, and the complex permittivity is calculated from it.

  • What Is an Oxidation Inhibitor in Oil?

    An oxidation inhibitor is an antioxidant additive that is gradually consumed to protect the insulating oil; while inhibitor remains, oxidation advances very slowly, and when it is depleted, oxidation accelerates.

  • What is an ultrasound camera for leaks and discharges?

    An ultrasound camera detects and locates the high-frequency sound produced by gas or air leaks and by electrical partial discharges, and displays it overlaid on a visual image.

  • What is an uncertainty budget and how is it built?

    An uncertainty budget is the ordered list of all the sources contributing to the doubt about a measurement result, with their magnitude and weight, which are combined according to a mathematical model of the measurement to obtain the combined and expanded uncertainty.

  • What is antenna gain?

    Antenna gain is the ratio between the power an antenna radiates in a given direction and the power an ideal isotropic antenna fed with the same power would radiate, including the antenna's own losses. It does not create power: it concentrates it in certain directions.

  • What is antenna polarization?

    Antenna polarization describes the orientation and time behavior of the electric field vector of the wave it radiates. It can be linear, circular or elliptical, and the transmitting and receiving antennas must match to avoid losing signal.

  • What is atmospheric transmittance in thermography?

    Atmospheric transmittance is the fraction of infrared radiation that passes through the air between the object and the camera; it falls with distance and humidity, and the camera compensates for it with entered parameters.

  • What is ATPV?

    ATPV is the thermal energy value, expressed in calories per square centimeter, at which a material or garment has a 50% probability that the skin underneath will suffer a second-degree burn when exposed to a test electric arc.

  • What is ball pass frequency?

    Ball pass frequency is the frequency at which the rolling elements of a bearing pass a fixed point on a raceway, and it appears in the vibration spectrum when that raceway has a defect.

  • What is beamwidth?

    Beamwidth is the angular opening of an antenna's main lobe. It is usually taken between the points where the power falls to half the maximum, about three decibels down. The narrower the beam, the higher the gain tends to be.

  • What is bit error rate?

    Bit error rate is the proportion of bits received incorrectly relative to the total number of bits transmitted; it is the direct measure of the quality of a digital link and depends on the signal-to-noise ratio and the modulation scheme.

  • What is blackbody radiation?

    It is the thermal radiation emitted by an ideal body that absorbs all incident radiation, and it depends solely on the body's temperature; it is the model used to interpret and calibrate the signal of a thermal imaging camera.

  • What Is Breakdown Voltage?

    Breakdown voltage is the voltage at which an insulator loses its ability to insulate and suddenly conducts; it depends on the thickness, the shape of the electrodes, the type of voltage and the condition of the material.

  • What is burn-in?

    Burn-in is a period of product operation, normally under elevated stress, intended to provoke and eliminate early failures before shipping to the customer.

  • What is C-rate?

    C-rate expresses charge or discharge current as a multiple of the battery's rated capacity: 1C is the current that, in theory, fully discharges it in one hour.