Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is hydrogen sulfide toxicity?

    Hydrogen sulfide is a toxic, colorless gas with a rotten-egg odor that inhibits cellular respiration; at high concentrations it knocks out the sense of smell and can leave a person unconscious within a few breaths.

  • What is hysteresis in a pressure sensor?

    Hysteresis in a pressure sensor is the difference between the output obtained for the same pressure depending on whether it is reached going up or going down; it indicates that the sensor “remembers” where it came from.

  • What is impedance bandwidth?

    It is the frequency range over which an antenna maintains an acceptable match with its feed line, that is, over which the reflection at its terminals stays below a limit set by the application.

  • What is incident energy?

    Incident energy is the amount of thermal energy per unit area received by a surface, at a given working distance, during an arc flash; it is used to choose protective equipment and evaluate the risk.

  • What is indirect electrocution by step voltage?

    Indirect electrocution by step voltage occurs when a person touches no conductor, but their two feet are at points on the ground with different potentials because a fault current is dispersing into the earth.

  • What is inert gas asphyxiation?

    Inert gas asphyxiation occurs when a non-toxic gas such as nitrogen, argon or helium displaces the oxygen in the air and a person is left without enough oxygen, with no odor, irritation or feeling of suffocation to warn them.

  • What is instantaneous field of view (IFOV)?

    IFOV is the angle covered by a single detector pixel; multiplied by distance, it gives the size of the area each pixel sees, and it sets the smallest object that can be measured reliably.

  • What is instrumentation amplifier noise?

    Instrumentation amplifier noise is the random signal the circuit itself adds to the measurement; it is specified referred to the input and determines the smallest signal that can be distinguished.

  • What Is Insulation Coordination?

    Insulation coordination is the selection of the dielectric strength of equipment and of protective devices so that expected overvoltages rarely cause a failure.

  • What is integration time?

    Integration time is the interval during which an analog-to-digital converter averages the input signal to produce a reading; a longer time reduces noise and mains interference, but makes the measurement slower.

  • What is irradiance and how is it expressed?

    Irradiance is the power of solar radiation striking a surface per unit area and is expressed in watts per square meter; its integral over time is irradiation, in energy per unit area.

  • What Is Leakage Flux?

    Leakage flux is the part of the magnetic flux that does not link both windings; it determines the leakage reactance, limits the short-circuit current and produces additional forces and losses.

  • What is let-go current?

    Let-go current is the highest current at which a person gripping a conductor can still open their hand voluntarily; above it, involuntary muscle contraction keeps them holding on and prolongs the exposure.

  • What is line and load regulation?

    Line regulation measures how much the output of a power supply changes when the input voltage varies; load regulation, how much it changes when the current demanded varies. Both show how stable the supply keeps its output.

  • What is lithium-ion cell chemistry?

    The chemistry of a lithium-ion cell is the combination of cathode, anode, electrolyte and separator materials. It defines the cell's voltage, energy per unit mass, power, service life, safety and cost, and it forces trade-offs among those properties.

  • What is load flow in an industrial installation?

    Load flow is the steady-state calculation of voltages, currents, and power at every point of an installation, given the loads and sources, to verify that the network operates within its limits.

  • What is loss tangent?

    Loss tangent, or dissipation factor, is the ratio between the energy a dielectric dissipates as heat and the energy it stores in each cycle; it indicates how imperfect the material is as an insulator or capacitor.

  • What is mean time between failures?

    Mean time between failures, known by the abbreviation MTBF, is the average operating time between one failure and the next in a population of repairable equipment. It describes the statistical reliability of a population, not how long an individual unit will last.

  • What is mean time to repair?

    Mean time to repair, known as MTTR, is the average time that elapses from the detection of a failure until the equipment is working again. It summarizes how quickly a system recovers and includes diagnosis, logistics, intervention and return to service.

  • What is measurement uncertainty?

    Measurement uncertainty is a parameter that characterizes the dispersion of the values that can reasonably be attributed to the measured quantity. It is not an error: it is the quantified doubt that accompanies a result.

  • What is mechanical looseness?

    It is excessive play between parts that should be firmly joined, such as a bearing in its housing, a machine on its base or a component on its shaft, and it shows up as vibration with many harmonics and unstable phase.

  • What is mechanical vibration and what quantities describe it?

    It is the oscillatory motion of a machine or structure about an equilibrium position; it is described by its amplitude, frequency and phase, and the amplitude can be expressed as displacement, velocity or acceleration.

  • What is memory depth?

    Memory depth is the number of samples an oscilloscope can store in one capture; it determines how much time can be recorded while maintaining a high sample rate.

  • What is metrological traceability?

    Metrological traceability is the property of a measurement result whereby it can be related to a reference, normally a national or international standard, through an unbroken, documented chain of calibrations, each with its own uncertainty.

  • What is mismatch between modules?

    Mismatch between modules occurs when interconnected modules have different I-V curves and the whole yields less than the sum of its parts, because the lowest current governs in series and the lowest voltage governs in parallel.

  • What is modulation and why is it needed?

    Modulation means changing a characteristic of a carrier (amplitude, frequency or phase) with the information to be sent; it is needed because the original signal cannot be transmitted effectively or share the spectrum without it.

  • What is multipath fading?

    Multipath fading occurs when the signal reaches the receiver over several paths with different delays and its components add or cancel according to their phase, so the received level varies even though the transmitter does not change.

  • What Is NFPA 70B and What Is It For?

    NFPA 70B is the standard on electrical equipment maintenance: it describes how to structure a preventive maintenance program, what to inspect and test, and what criteria to use in deciding the frequency.

  • What is NFPA 70E and what does it cover?

    NFPA 70E is a U.S. standard for electrical safety in the workplace: it focuses on protecting people from electric shock and arc flash through risk assessment, an electrically safe work condition and the selection of protection.

  • What is nominal operating cell temperature?

    Nominal operating cell temperature (NOCT) is the temperature reached by a cell in a module mounted on an open rack, at open circuit, under 800 W/m² of irradiance, an ambient temperature of 20 °C and a wind speed of 1 m/s.