What is considered a confined space?

A confined space is a place large enough for a person to enter and work in, with limited means of entry and exit, and not designed for continuous occupancy; its conditions, not its size, are what make it dangerous.

The three characteristics

The usual definition combines three traits that must all be met at once:

  1. The body can enter it and work can be performed inside.
  2. It has limited or restricted access or exits for getting in or out easily, for example a small manway, a vertical ladder or a narrow passage.
  3. It is not designed for continuous human occupancy.

If any of these is missing, it is not a confined space in this sense. A large machine room with normal doors is not one; a storage tank with a single manway is.

Common examples

  • Tanks, reactors, boilers and pressure vessels.
  • Silos, hoppers and storage for grain or bulk materials.
  • Pits, sumps, utility vaults and sewers.
  • Large ducts, ventilation ducts and service tunnels.
  • Cisterns, wells and deep trenches with poor ventilation.

Why the definition does not mention size

Size does not determine the hazard. What determines it is what happens when the air is not renewed and escape is difficult. A small space with easy access can be less serious than a huge one with a single exit. The definition seeks to identify places where conditions can deteriorate without the person inside noticing, and where rescue is complicated.

What changes once it is identified as such

Classifying a place as a confined space triggers a set of controls: inventory and signage, hazard assessment, entry procedures, atmospheric measurements, ventilation, communication, monitoring from outside and a rescue plan. Many organizations consider it the first step: without an inventory there is no control.

When the classification shifts

The same space can change status. A clean, ventilated tank with no other sources of hazard does not present the same risks as that same tank with residues or with welding work under way. That is why the assessment is done by space and by task, and reviewed when conditions change.

A word of caution

The legal definition and its criteria depend on the current Mexican regulations, which should be consulted. Entry into these spaces must be done by trained and authorized personnel, with the controls set by the applicable procedure.

This guide is for information only. Work involving electrical risk, heights or hazardous atmospheres must be carried out by qualified and authorized personnel, following the applicable regulations.