Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is normalized error in an interlaboratory comparison?

    Normalized error compares the difference between a laboratory's result and the reference value with the combined uncertainty of both; a value whose magnitude does not exceed one indicates agreement within what was stated.

  • What Is Oil Acidity and What Does It Indicate?

    Oil acidity, measured as the neutralization number, quantifies the acidic compounds formed by oxidation; a sustained increase indicates aging of the oil and a risk of sludge and attack on the cellulose.

  • What is orthogonal frequency division multiplexing?

    Orthogonal frequency division multiplexing (OFDM) distributes data across many narrow subcarriers that are orthogonal to each other, so that each one sees a nearly flat channel and the system withstands multipath better.

  • What is oxygen deficiency?

    Oxygen deficiency is an oxygen concentration in the air below what is needed to breathe safely; it can be detected only with an instrument, because it has no odor or color and the affected person's judgment deteriorates before they notice it.

  • What is partial discharge inception voltage?

    Partial discharge inception voltage is the lowest voltage at which, as the voltage is gradually raised, partial discharges above a defined magnitude threshold are detected. It depends on the defect, on the sensitivity of the measuring system and on the test conditions.

  • What is phase in vibration analysis?

    Phase indicates where a vibration is in its cycle relative to a reference, expressed in degrees, and it is used to determine how different points on the machine move relative to each other and to distinguish faults that have the same spectrum.

  • What is potential-induced degradation?

    Potential-induced degradation (PID) is a loss of module power caused by the voltage difference between the cells and the grounded frame, which promotes leakage currents and the migration of ions toward the cells, especially in the presence of humidity and heat.

  • What is pour point?

    Pour point is the lowest temperature at which an oil still flows when cooled under standardized test conditions; below it, the oil behaves like a semisolid.

  • What is power quality?

    Power quality describes how close the supply is to a stable sinusoidal voltage with suitable amplitude and frequency, and how well the load tolerates deviations.

  • What is protection coordination?

    Protection coordination is the setting of an installation's protective devices so that, during a fault, the closest device operates first and the rest remain as backup, without leaving equipment unprotected.

  • What is radiation efficiency?

    Radiation efficiency is the fraction of the power entering the antenna terminals that is actually radiated into space; the rest is dissipated as heat in the conductors and dielectrics of the antenna itself.

  • What is rated withstand voltage?

    Rated withstand voltage is the test voltage value that insulation must resist, without disruptive discharge, under standardized test conditions; it is not the operating voltage.

  • What Is Reactive Power and Why Is It Compensated?

    Reactive power is the part of power that oscillates between the source and the magnetic or electric fields of the load without being converted into useful work; it is compensated to reduce the current flowing through the network and free up capacity.

  • What Is Receiver Sensitivity?

    The sensitivity of a receiver is the minimum signal level at its input at which it achieves the required reception quality, for example a given signal-to-noise ratio or error rate.

  • What is reflected apparent temperature?

    Reflected apparent temperature is the equivalent temperature of the ambient radiation that reflects off the object toward the camera; it must be entered so that the measurement subtracts that contribution.

  • What is regenerative braking?

    Regenerative braking uses the electric motor as a generator during deceleration: it converts part of the vehicle's kinetic energy into electricity that recharges the battery, and it reduces the work of the friction brakes.

  • What Is Reproducibility in a Measurement?

    Reproducibility is the precision of a measurement when conditions change: a different operator, instrument, laboratory, location or time, even though the same thing is measured with the same method.

  • What is resolution versus accuracy in an instrument?

    Resolution is the smallest change the instrument can display; accuracy is how close the reading is to the true value. An instrument can have high resolution and poor accuracy.

  • What is return loss?

    It is the measure, in decibels, of how much incident power is returned by reflection: the higher the value, the lower the reflection and the better the match.

  • What is root cause analysis?

    Root cause analysis is a method for finding the original condition that made a failure possible, so that the correction eliminates the problem and not just its symptom.

  • What is rotation order in a spectrum?

    Rotation order is a frequency expressed as a multiple of the machine's rotational speed: the first order is once per revolution, the second is twice per revolution and so on, which makes it possible to compare spectra at different speeds.

  • What is rotor unbalance?

    It is an uneven distribution of mass around the axis of rotation, so that the center of mass does not coincide with the axis and the rotation generates a centrifugal force that produces vibration at the rotating frequency.

  • What is selectivity between circuit breakers?

    Selectivity between circuit breakers is the property by which, during an overcurrent, only the breaker immediately upstream of the fault opens and the others remain closed.

  • What is shaft misalignment?

    It is a lack of coincidence between the centerlines of two coupled shafts, whether through a parallel offset, an angle between them or both, and it generates additional forces in the coupling and the bearings.

  • What is shielding effectiveness?

    Shielding effectiveness measures how much a metal barrier attenuates an electromagnetic field: it is the ratio, in decibels, between the field without the shield and the field with the shield at the same point.

  • What Is Sludge in Insulating Oil?

    Sludge in insulating oil consists of insoluble, polymerized oxidation products that deposit on windings, core and ducts, hindering cooling and accelerating the aging of the transformer.

  • What is soil resistivity?

    Soil resistivity is the opposition a volume of soil offers to the flow of current; it is expressed in ohm-meters and determines how much resistance a buried electrode will have.

  • What is spread spectrum?

    Spread spectrum is a technique that distributes the signal over a bandwidth much greater than the information requires, using a code known to the receiver, which provides resistance to interference and allows several systems to share the band.

  • What is spreading resistance?

    It is the resistance the soil offers to the current flowing from the electrode toward remote earth; it is not the resistance of the electrode metal, but that of the volume of earth surrounding it.

  • What Is Surface Tracking?

    Surface tracking is the formation of carbonized conductive paths on the surface of an insulator, caused by small leakage currents and discharges in the presence of contamination and moisture; the damage is permanent.